On 1/28/24 21:22, Sven Schnelle wrote:
When the maximum count of SCRIPTS instructions is reached, the code
stops execution and returns, but fails to decrement the reentrancy
counter. This effectively renders the SCSI controller unusable
because on next entry the reentrancy counter is still above the limit.

This bug was seen on HP-UX 10.20 which seems to trigger SCRIPTS
loops.

Fixes: b987718bbb ("hw/scsi/lsi53c895a: Fix reentrancy issues in the LSI controller 
(CVE-2023-0330)")
Signed-off-by: Sven Schnelle <sv...@stackframe.org>

Tested-by: Helge Deller <del...@gmx.de>

Thanks!
Helge

---
  hw/scsi/lsi53c895a.c | 1 +
  1 file changed, 1 insertion(+)

diff --git a/hw/scsi/lsi53c895a.c b/hw/scsi/lsi53c895a.c
index 34e3b89287..d607a5f9fb 100644
--- a/hw/scsi/lsi53c895a.c
+++ b/hw/scsi/lsi53c895a.c
@@ -1159,6 +1159,7 @@ again:
          lsi_script_scsi_interrupt(s, LSI_SIST0_UDC, 0);
          lsi_disconnect(s);
          trace_lsi_execute_script_stop();
+        reentrancy_level--;
          return;
      }
      insn = read_dword(s, s->dsp);


Reply via email to