On Mon, Nov 02, 2026 at 09:22:15AM +0000, Jamin Lin wrote:
> npcm7xx has no versioned machine type, so compat cannot reach it. Turn
> the property on here instead. The companion shares the EHCI bus, so
> the EHCI carries the property.

Checked quanta-gsj and npcm750-evb: a second HID device still fits,
through the hub.

Reviewed-by: Junjie Cao <[email protected]>
Tested-by: Junjie Cao <[email protected]>

Reply via email to