On 2012-09-03 18:15, Avi Kivity wrote:
> On 09/03/2012 07:02 PM, Jan Kiszka wrote:
> 
>>>>> Looks like the optimal condition is ((s->icw3 & ~s->eclr) != 0) (i.e.
>>>>> bit set in icw3 but clear in eclr).
>>>>
>>>> The standard PC values are optimal: 4 for master, 2 for slave.
>>>
>>> Can you explain why?  I saw that icw3 is always ORed with eclr, so my
>>> condition will catch exactly those cases where a change in behaviour
>>> occurs, and no more.
>>
>> The values above are what every user of the PIC cascaded on our targets
>> must program to use them. So We will find them in the state once any
>> relevant guest code was able to run (e.g. the BIOS).
>>
> 
> Suppose the bios has not run yet?

Then we must save the 0.

Your logic will force us to save in all standard cases (ELCR's bit for
IRQ2 must not be set by a guest). So it's not really helpful.

Jan

-- 
Siemens AG, Corporate Technology, CT RTC ITP SDP-DE
Corporate Competence Center Embedded Linux

Reply via email to