This is now the second starter motor where I've had this problem, so I'm starting to think it's the car and not the starter.
With the battery connected and no ignition power the starter motor runs constantly - the only way to stop it is to disconnect the battery. The starter is not engaging the flywheel, so it's not trying to turn over the engine. It had been running fine for about half a day before this and the only common thing with the previous starter is that both hadn't been on the car that long and showed the problem after the engine got hot, however I now have the current starter wrapped in a flexible head shield. There is an immobiliser on the car that immobilises the starter motor as one of the 2 circuits, so could this potentially be the cause? The car is my H4 with it's CVH turbo engine using the EFi management from the FRST donor. Any help will be appreciated as I need to sort this out to get the car to it's MoT retest next week - it only failed because the rear brake cylinders had seized, which wasn't bad seeing the car hadn't moved since may! Regards, Steve -- www.h4-turbo.co.uk --~--~---------~--~----~------------~-------~--~----~ You received this message because you are subscribed to the Google Groups "Quantum Owners Group" group. To post to this group, send email to [email protected] To unsubscribe from this group, send email to [email protected] For more options, visit this group at http://groups.google.com/group/quantumowners?hl=en IMPORTANT NOTE: All information presented herewith is provided on an "As Is" basis, without warranty or the implication thereof. Neither the Quantum Owners Club nor the individuals associated with the Quantum Owners Club or in the preparation of the above information shall have any liability to any person or entity with respect to liability, loss, or damage caused or alleged to be caused directly or indirectly by the instructions contained within this or related message(s). -~----------~----~----~----~------~----~------~--~---