On Sat, 10 Feb 2007 18:55:45 +0100, Rune Magnussen wrote: >Hi. > >I am trying to to get my Meinberg DCF77 C51 unit to work. The problem is >that ntpd does not see any timecodes even though thr unit is synchronised >to the radiosignal. > >The clock is connected via a modem cable with a null-modem >adapter. I tried with a serial printer cable as well, but not for long. The >serial port is detected by the kernel. As described in the docs I made a >symlink /dev/refclock-0 to /dev/ttyS0. I guess that /dev/ttyS0 is the right >one. >as the PC only has one serial port on the outside. > >The DCF77 C51 shows up as GENERIC(0) with refid DCFa but the clock is never >"reached". I have activated clockstats in ntpd, but nothing shows up. > >What should I try next?
Have you tried without the null-modem cable? IIRC you need a straight cable (like you would use between computer and external modem). -- Maurice _______________________________________________ questions mailing list [email protected] https://lists.ntp.isc.org/mailman/listinfo/questions