Hello Tom,
I was checking the TRACE 4 log and I found that the packets are not
identical. I have the same field like CISCO, the Acct-Delay-Time that
is different for the duplicate packet and also the timestamp field.
Ok here is the problem, so how can I change radiator to check only the
NAS-IP-Address and the Acct-Session-Id for duplicates?
I will check the MAX TNT documentation to see if there are a way to avoid
send the Acct-Delay-Time field in the packet.
How did you solve the problem with CISCO?
At the end I send a copy of the original packet and the duplicate.
Best regards.
Teddy
On 08-03-2000 12:51 PM tom minchin <[EMAIL PROTECTED]> wrote:
>
> It compares the whole packet (well the MD5 checksum from memory).
>
> *hops on hobby horse*
>
> This means if your duplicate packets aren't identical then Radiator can't
> detect and ignore duplicates (eg Cisco has Acct-Delay-Time which changes
> in value for each retransmitted packet).
>
> Check your Trace 4 log and compare the Stop records and see what the difference
> is.
>
> *heads to sunset*
>
> [EMAIL PROTECTED]
>
--------------------
Sat Feb 26 00:29:13 2000
User-Name = "xxxxxxxx"
NAS-IP-Address = xx.xx.xx.xx
NAS-Port = 107
NAS-Port-Type = Async
Acct-Status-Type = Stop
Acct-Delay-Time = 21
Acct-Session-Id = "305110595"
Acct-Authentic = RADIUS
Acct-Session-Time = 3294
Acct-Input-Octets = 482876
Acct-Output-Octets = 328545
Acct-Input-Packets = 9985
Acct-Output-Packets = 2410
Ascend-Disconnect-Cause = remoteEndHungup
Ascend-Connect-Progress = prLanSessionUp
Ascend-Xmit-Rate = 33600
Ascend-Data-Rate = 33600
Ascend-PreSession-Time = 15
Ascend-Pre-Input-Octets = 353
Ascend-Pre-Output-Octets = 336
Ascend-Pre-Input-Packets = 12
Ascend-Pre-Output-Packets = 12
Ascend-First-Dest = 255.255.255.255
Ascend-Multilink-ID = 1100
Ascend-Num-In-Multilink = 0
Acct-Link-Count = "<0><0><0><1>"
Acct-Multi-Session-Id = "0000044c"
Ascend-Modem-PortNo = 9
Ascend-Modem-SlotNo = 5
Ascend-Modem-ShelfNo = 1
Calling-Station-Id = "3460796"
Called-Station-Id = "321900"
Framed-Protocol = 262
Framed-IP-Address = xx.xx.xxx.xx
Timestamp = 951510532
Sat Feb 26 00:29:16 2000
User-Name = "xxxxxxxx"
NAS-IP-Address = xx.xx.xx.xx
NAS-Port = 107
NAS-Port-Type = Async
Acct-Status-Type = Stop
Acct-Delay-Time = 28
Acct-Session-Id = "305110595"
Acct-Authentic = RADIUS
Acct-Session-Time = 3294
Acct-Input-Octets = 482876
Acct-Output-Octets = 328545
Acct-Input-Packets = 9985
Acct-Output-Packets = 2410
Ascend-Disconnect-Cause = remoteEndHungup
Ascend-Connect-Progress = prLanSessionUp
Ascend-Xmit-Rate = 33600
Ascend-Data-Rate = 33600
Ascend-PreSession-Time = 15
Ascend-Pre-Input-Octets = 353
Ascend-Pre-Output-Octets = 336
Ascend-Pre-Input-Packets = 12
Ascend-Pre-Output-Packets = 12
Ascend-First-Dest = 255.255.255.255
Ascend-Multilink-ID = 1100
Ascend-Num-In-Multilink = 0
Acct-Link-Count = "<0><0><0><1>"
Acct-Multi-Session-Id = "0000044c"
Ascend-Modem-PortNo = 9
Ascend-Modem-SlotNo = 5
Ascend-Modem-ShelfNo = 1
Calling-Station-Id = "3460796"
Called-Station-Id = "321900"
Framed-Protocol = 262
Framed-IP-Address = xx.xx.xxx.xx
Timestamp = 951510528
--
Teddy Victor, Mercado Rodrigo
Div. Comunicaciones
PROCOM S.R.L.
e-mail: [EMAIL PROTECTED]
Santa Cruz
Bolivia
===
Archive at http://www.starport.net/~radiator/
To unsubscribe, email '[EMAIL PROTECTED]' with