Hello Tom,

I was checking the TRACE 4 log and I found that the packets are not 
identical. I have the same field like CISCO, the Acct-Delay-Time that
is different for the duplicate packet and also the timestamp field.

Ok here is the problem, so how can I change radiator to check only the
NAS-IP-Address and the Acct-Session-Id for duplicates?
I will check the MAX TNT documentation to see if there are a way to avoid
send the Acct-Delay-Time field in the packet.

How did you solve the problem with CISCO?

At the end I send a copy of the original packet and the duplicate.

Best regards.

Teddy

On 08-03-2000 12:51 PM tom minchin <[EMAIL PROTECTED]> wrote: 
> 
> It compares the whole packet (well the MD5 checksum from memory).
> 
> *hops on hobby horse*
> 
> This means if your duplicate packets aren't identical then Radiator can't
> detect and ignore duplicates (eg Cisco has Acct-Delay-Time which changes
> in value for each retransmitted packet).
> 
> Check your Trace 4 log and compare the Stop records and see what the difference
> is.
> 
> *heads to sunset*
> 
> [EMAIL PROTECTED]
> 
--------------------
Sat Feb 26 00:29:13 2000
        User-Name = "xxxxxxxx"
        NAS-IP-Address = xx.xx.xx.xx
        NAS-Port = 107
        NAS-Port-Type = Async
        Acct-Status-Type = Stop
        Acct-Delay-Time = 21
        Acct-Session-Id = "305110595"
        Acct-Authentic = RADIUS
        Acct-Session-Time = 3294
        Acct-Input-Octets = 482876
        Acct-Output-Octets = 328545
        Acct-Input-Packets = 9985
        Acct-Output-Packets = 2410
        Ascend-Disconnect-Cause = remoteEndHungup
        Ascend-Connect-Progress = prLanSessionUp
        Ascend-Xmit-Rate = 33600
        Ascend-Data-Rate = 33600
        Ascend-PreSession-Time = 15
        Ascend-Pre-Input-Octets = 353
        Ascend-Pre-Output-Octets = 336
        Ascend-Pre-Input-Packets = 12
        Ascend-Pre-Output-Packets = 12
        Ascend-First-Dest = 255.255.255.255
        Ascend-Multilink-ID = 1100
        Ascend-Num-In-Multilink = 0
        Acct-Link-Count = "<0><0><0><1>"
        Acct-Multi-Session-Id = "0000044c"
        Ascend-Modem-PortNo = 9
        Ascend-Modem-SlotNo = 5
        Ascend-Modem-ShelfNo = 1
        Calling-Station-Id = "3460796"
        Called-Station-Id = "321900"
        Framed-Protocol = 262
        Framed-IP-Address = xx.xx.xxx.xx
        Timestamp = 951510532
 
Sat Feb 26 00:29:16 2000
        User-Name = "xxxxxxxx"
        NAS-IP-Address = xx.xx.xx.xx
        NAS-Port = 107
        NAS-Port-Type = Async
        Acct-Status-Type = Stop
        Acct-Delay-Time = 28
        Acct-Session-Id = "305110595"
        Acct-Authentic = RADIUS
        Acct-Session-Time = 3294
        Acct-Input-Octets = 482876
        Acct-Output-Octets = 328545
        Acct-Input-Packets = 9985
        Acct-Output-Packets = 2410
        Ascend-Disconnect-Cause = remoteEndHungup
        Ascend-Connect-Progress = prLanSessionUp
        Ascend-Xmit-Rate = 33600
        Ascend-Data-Rate = 33600
        Ascend-PreSession-Time = 15
        Ascend-Pre-Input-Octets = 353
        Ascend-Pre-Output-Octets = 336
        Ascend-Pre-Input-Packets = 12
        Ascend-Pre-Output-Packets = 12
        Ascend-First-Dest = 255.255.255.255
        Ascend-Multilink-ID = 1100
        Ascend-Num-In-Multilink = 0
        Acct-Link-Count = "<0><0><0><1>"
        Acct-Multi-Session-Id = "0000044c"
        Ascend-Modem-PortNo = 9
        Ascend-Modem-SlotNo = 5
        Ascend-Modem-ShelfNo = 1
        Calling-Station-Id = "3460796"
        Called-Station-Id = "321900"
        Framed-Protocol = 262
        Framed-IP-Address = xx.xx.xxx.xx
        Timestamp = 951510528
 



--
Teddy Victor, Mercado Rodrigo
Div. Comunicaciones
PROCOM S.R.L.
e-mail: [EMAIL PROTECTED]
Santa Cruz
Bolivia
            
            
            
            
            

===
Archive at http://www.starport.net/~radiator/
To unsubscribe, email '[EMAIL PROTECTED]' with
'unsubscribe radiator' in the body of the message.

Reply via email to