Mac,
No way to do this effectively. You need at least 72 cells to effectively charge 
a 24V battery, especially during hot weather.
Bob-O

On Jun 4, 2013, at 8:04 AM, Mac Lewis wrote:

Hello wrenches,

Is there a good method to charge 24V battery bank with single 60 cell modules?  
Ideally, I'd like to charge a 24 V bank with a Kyocera 245GX-LFB.  However, at 
NOTC the Vmp is 26.8V.  Any good way to do this?

Thanks in advance.
-- 



Mac Lewis