Cory I tried a railless S-5 system on a metal roof and will never do it again! Looks great and very professional. The clearance under the modules is a real problem for wire management and I had to switch out a bad microinverter and it was really difficult compared to have a rails. Had to disconnect all adjoining modules from the S-5 which allowed things to shift a bit making replacement an absolute pain in the butt. It was a steep roof too which added to the hassle....bad choice for my first try ,but it was a triagular array shape due to shading issue sand dormer locations. That was why I opted for railess, since the cutting of rails would have been very time consuming.
Bill Bill Hoffer PE NABCEP Certified Solar PV Installerâ„¢ Sunergy Engineering Services PLLC 420 SE Wyers St ,# 1823. P.O. Box 1823 White Salmon, WA 98672 bhof...@sunergyengineeringservices.com Cell:(509)679-6165 sunergyengineeringservices.com On Sun, May 17, 2020 at 1:55 PM Corey Shalanski <coreso...@gmail.com> wrote: > I am wondering if anyone on the List has significant experience installing > rail-less racking systems (Quick Mount PV Quick Rack, Roof Tech E Mount > AIR, SnapNrack RL Universal, etc.) and can speak to the pros and cons > versus rail-based systems? > Also wondering if anyone has strong opinions regarding the lesser air gap > below modules with rail-less systems and how much, if at all, that might > affect production? *bonus points awarded for providing quantitative data > > -- > Corey Shalanski > Jah Light Solar > Portland, Jamaica > _______________________________________________ > List sponsored by Redwood Alliance > > List Address: RE-wrenches@lists.re-wrenches.org > > Change listserver email address & settings: > http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org > > List-Archive: > http://www.mail-archive.com/re-wrenches@lists.re-wrenches.org/maillist.html > > List rules & etiquette: > www.re-wrenches.org/etiquette.htm > > Check out or update participant bios: > www.members.re-wrenches.org > > -- William Hoffer 420 SE Wyers Street P.O. Box 1823 White Salmon, WA 98672-1823 suneng...@gmail.com <bhof...@sunergyengineeringservices.com>
_______________________________________________ List sponsored by Redwood Alliance List Address: RE-wrenches@lists.re-wrenches.org Change listserver email address & settings: http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org List-Archive: http://www.mail-archive.com/re-wrenches@lists.re-wrenches.org/maillist.html List rules & etiquette: www.re-wrenches.org/etiquette.htm Check out or update participant bios: www.members.re-wrenches.org