Tente usar no router :
> frame-relay lmi-type q933a
>
e no MUX:
ANNEX A na porta que vai para o router
> ----------
> De: Jose Matheus Pinheiro - CONECT-
> #200502#[SMTP:[EMAIL PROTECTED]]
> Enviada: Quinta-feira, 17 de Fevereiro de 2000 16:07
> Para: Lista de Discuss�o Rede Wan
> Cc: [EMAIL PROTECTED]
> Assunto: [redewan] Link frame-relay
>
> Lista de Discuss�o Rede Wan - http://www.networkdesigners.com.br
>
>
> Pessoal,
>
> Estamos configurando um link frame-relay em uma das seriais de um
> Cisco 2501 - IOS 11.1(8).
>
> Acontece q. esse link vem de um MUX(NewBridge - 3600) cujo
> patch-panel
> � DB25 e usamos um conversor para V-35 ,feito conforme especifica��o dada
> pela prestadora, j� q. o cabo Cisco � nesse padr�o (V35-DTE).
> Hoje tenho nessa path-panel duas lp's ponto-a-ponto com mesmo conversor
> e funcionando.
>
> Acontece q. em teste com equipamento da prestadora do link, o sinal
> �
> pego por S�o Paulo, j� conectando-se o roteador, nenhum sinal � pego.
>
> E a porta serial fica up, mas "line protocol down" e na
> sub-interface
> fica serial down e line protocol down. J� no PVC temos DLCI USAGE = LOCAL
> e
> PVC STATUS = DELETED e no lmi temos (Frame Relay DTE) LMI TYPE = ANSI
>
> Pelos padr�es b�sicos de config. sem querer inventar nada, acho q.
> deveria aparecer algum sinal na prestadora, MAS nada disso acontece.
>
> Minha pergunta: o cabo V.35-DTE q. acompanha o Cisco, no caso de FR
>
> sofre alguma mudan�a de c�digo? Pelos papers q. peguei da Cisco, nada
> fala.
>
> OBRIGADO por qq. informa��o,
>
> Pinheiro - GCNET / Unicamp
> e-mail: [EMAIL PROTECTED]
>
> OBS: Config. b�sica;
> ....
> interface Serial1
> description "unicamp <-> fr "
> no ip address
> encapsulation frame-relay IETF
> frame-relay lmi-type ansi
> !
> interface Serial1.1 point-to-point
> ip address xxx.xxx.xxx.xxx aaa.aaa.aaa.aaa
> ip broadcast-address yyy.yyy.yyy.yyy
> frame-relay interface-dlci nn
> !
>
> Serial1 is up, line protocol is down
> MTU 1500 bytes, BW 1544 Kbit, DLY 20000 usec, rely 255/255, load 1/255
> Encapsulation FRAME-RELAY IETF, loopback not set, keepalive set (10 sec)
> LMI enq sent 814, LMI stat recvd 0, LMI upd recvd 0, DTE LMI down
> LMI enq recvd 0, LMI stat sent 0, LMI upd sent 0
> LMI DLCI 0 LMI type is ANSI Annex D frame relay DTE
> Broadcast queue 0/64, broadcasts sent/dropped 0/0, interface broadcasts
> 6
> Last input never, output 00:00:13, output hang never
> Last clearing of "show interface" counters never
> Input queue: 0/75/0 (size/max/drops); Total output drops: 0
> Queueing strategy: weighted fair
> Output queue: 0/64/0 (size/threshold/drops)
> Conversations 0/5 (active/max active)
> Reserved Conversations 0/0 (allocated/max allocated)
> 5 minute input rate 0 bits/sec, 0 packets/sec
> 5 minute output rate 0 bits/sec, 0 packets/sec
> 0 packets input, 0 bytes, 0 no buffer
> Received 0 broadcasts, 0 runts, 0 giants
> 0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
> 815 packets output, 11854 bytes, 0 underruns
> 0 output errors, 0 collisions, 277 interface resets
>
> Serial1.1 is down, line protocol is down
> MTU 1500 bytes, BW 1544 Kbit, DLY 20000 usec, rely 255/255, load 1/255
> Encapsulation FRAME-RELAY IETF
>
>
>
>
> ______________________________________________________________________
>
|