Scott, I believe that your PA is a TLD1683, 100 watt intermittent duty unit for the 150.8-162 MHz band. It should have the TFD6112A Exciter Filter and the TFD6102A Harmonic Filter, both of which are designed for the 150.8-174 MHz band.
If you intend to operate this station in the 2m band, you'll need the TLD1682 PA, which comprises the TLD5952 PA Board, the TFD6111A Exciter Filter, and the TFD6101A Harmonic Filter. The filters are designed to pass the 132-150.8 MHz band. While it is possible to modify the filters to work properly on 2m, it takes a lot of time, money, and effort to modify the PA board for the low split. Some dedicated individuals have gone this route, but most vow they'll never do it again. Instructions for tuning the filters are available in the Repeater-Builder site. There is very little difference between the intermittent and continuous duty PAs, other than the heat sink and a thermistor. The intermittent-duty PAs are rated for a 20% duty cycle- one minute on and four minutes off. It probably could run 100% with forced air cooling. The thermistor, which cuts back power when the PA gets hot, is not used in continuous duty PAs. 73, Eric Lemmon WB6FLY wn1b8 wrote: > I recently picked up a Micor Compa-Station exciter/PA. I know it's for 132-174 MHz. and I believe it to be a 100 watt PA deck, but I can't seem to find what the duty cycle is. The PA board part number is TLD5953A1093R. It has the 14 1/2" long Micor fins across the top of the module. The module, with the fins, is 6" high. I know this isn't the 100% duty cycle configuration, but can it be run at 100% if it has constant forced air cooling across the fins? Also, the board appears to be the same for the 100 watt 100% configuration. Is it possible to simply replant this board in the larger chassis/heat sink? Assuming for a moment that I could find a dead one. > > Any help and/or advice will be greatly appreciated. > > Scott Madison, WN1B > > > Yahoo! Groups Links > > > > Yahoo! Groups Links <*> To visit your group on the web, go to: http://groups.yahoo.com/group/Repeater-Builder/ <*> To unsubscribe from this group, send an email to: [EMAIL PROTECTED] <*> Your use of Yahoo! Groups is subject to: http://docs.yahoo.com/info/terms/