At 12/12/2007 21:49, you wrote:

>Randy,
>
>I'm trying to recall...is this a rig where one ICOM has the temperature 
>compensation network, and develops a control voltage which is then 
>distributed and shared by all the other ICOMs in the radio? If so, and the 
>problem just showed up one day, perhaps there's some RF bypass cap or 
>other component that's failed within the ICOM itself, allowing RF to 
>travel that DC temperature control line.

Forgot to mention: I thought about this too & tried severing the comp. line 
between TX & RX ICOMs.  No effect on the spur problem.

Bob NO6B