Those two versions are not compatible. The magic number doesn't increment unless the file format changes. 0x2169 is the version for 7.0.2 and 0x216e is the version for file format for 8.0.4. The 0x14 in the error message doesn't even make sense.
If you want to process these files on F10, then just download and compile the source for 7.0.2 and use the binary to process the files only. On Fri, Jun 19, 2009 at 8:16 PM, vu pham<[email protected]> wrote: > I copy all sa?? files from remote systems to my workstation for processing. > All remote systems are Redhat 5 with sysstat-7.0.2-3.el5. My workstation is > FC10 with sysstat-8.0.4-5.fc10.i386. > When I run sar -f , I get the error > > v...@ef ~]$ sar -f sar/jetco-xen/sa/sa11 > Invalid system activity file: sar/jetco-xen/sa/sa11 (0x14) > > My first guess is newer sar cannot read files of older sar. Anyone > experiences this problem ? I can process these files from their own servers > but then I have to update all the scripts to the remote systems when the > sripts are changed/updated. > > Any suggestion is greatly appreciated. -- Justin Cook _______________________________________________ rhelv5-list mailing list [email protected] https://www.redhat.com/mailman/listinfo/rhelv5-list