No, there is no way, unfortunately (referring to V. 5.0). This also 
means that you have to be careful when you calculate a powder 
pattern with ATOMS - it doesn't take into account mixed 
occupancies, vacancies, etc.. 
(You may be able to trick the program a bit by choosing an 
element with an 'equivalent' no. of electrons.)

Uwe

> 
>       Dear All,
> 
>       is there any way of defining the "site occupation factor" of an atom in
> the software "ATOMS"??????
> 
>       Gracias!!
> 
>       ana
> 
> -- 
> Ana Isabel Becerro
> ICMSE (CSIC)
> Avda. Américo Vespucio s/n
> 41092 Sevilla (Spain)
> Tel: 34-95 4489576
> Fax: 34 95 4460665
> 




>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
Dr. Uwe Kolitsch