Is there anyway we can compare an SNMP value to a
previously retrieved value in order to alarm on a comparison?
Example:
Router S0 Error Count on 1st check:
8800
Check if change greater than 10 alarm - difference
unknown, no alarm
Router S0 Error Count on 2nd check:
8802
Check if change greater than 10 alarm - difference
of 2 found, no alarm
Router S0 Error Count on 3rd check:
8840
Check if change greater than 10 alarm - difference
of 38 found, alarm sent
Router S0 Error Count on 4th check:
8841
Check if change greater then 10 alarm - difference
of 1 found, no alarm
Would this be possible, because it would be a
great advantage to us to monitor line errors this way.
If it's not possible, does anyone on the list have
a suggestion that would work?
Thank You,
Robert Fesig, Network Engineer American Computer Associates, Inc. (570) 874-1910 |