I finally have gotten back around to getting my CS-516 back up and
working, and I am having a problem..
To actually connect to a console takes somewhere in the area of 5
minutes, I hope that is not normal. Also, many times I get "Connection
refused by remote host" although I could connect 20 minu
You may want to try the no-exec under your line con 0
Maybe there's a bunch of noise of the line from the other boxes trying
to establish a connection.
Just a thought.
Tim
On 17 Apr 2002 14:20:12 -0400, [EMAIL PROTECTED] ("Tim Lovelace")
wrote:
>I finally have gotten back around to getting
You may want to try exec-timeout 0 0 under line con0
and no exec under line 1 16.
If you console into the 516-CS, it will take 5-10
minutes. It is normal according to Cisco. It take
about 30 sec if you telnet into it instead of using
the console.
Han.
--- "[EMAIL PROTECTED] (Timothy Ouellette)"
I think I made a mistake in my last post. Anyways, here's my config
of my cs-516.
ccie-lab#sh conf
Using 650 out of 32512 bytes
!
version 9.21
no service pad
service password-encryption
!
hostname ccie-lab
!
clock timezone EST -5
enable password 7 051F0F02
!
no ip domain-lookup
ip tcp synwait-ti
4 matches