On Thu, Apr 15, 2010 at 09:25:24PM +0200, Bernd Walter wrote:
> On Thu, Apr 15, 2010 at 09:04:05PM +0200, Bernd Walter wrote:
> > On Thu, Apr 15, 2010 at 01:45:36PM -0400, Mike Tancsa wrote:
> > > At 01:36 PM 4/15/2010, Bernd Walter wrote:
> > >
> > > >Is the sensor prohibiting the use of USB RS23
On Thu, Apr 15, 2010 at 09:04:05PM +0200, Bernd Walter wrote:
> On Thu, Apr 15, 2010 at 01:45:36PM -0400, Mike Tancsa wrote:
> > At 01:36 PM 4/15/2010, Bernd Walter wrote:
> >
> > >Is the sensor prohibiting the use of USB RS232 in any way?
> >
> > Just our wallets :) Extra cost to include it and
On Thu, Apr 15, 2010 at 01:45:36PM -0400, Mike Tancsa wrote:
> At 01:36 PM 4/15/2010, Bernd Walter wrote:
>
> >Is the sensor prohibiting the use of USB RS232 in any way?
>
> Just our wallets :) Extra cost to include it and the case would need
> to change as well as its in an environment where i
On 15 Apr 2010, at 18:24, Mike Tancsa wrote:
> At 12:59 PM 4/15/2010, Rui Paulo wrote:
>
>> If not, maybe there's some way to do this by changing the hints file.
>
> Prior to /boot/loader running, is that even consulted ?
Right, I missed that...
Regards,
--
Rui Paulo
On 15 Apr 2010, at 17:18, Julian Elischer wrote:
> On 4/15/10 3:03 AM, Mike Tancsa wrote:
>> At 12:04 AM 4/15/2010, per...@pluto.rain.com wrote:
>>> Mike Tancsa wrote:
>>>
>>> > I have an embedded device (Alix box) that is running RELENG_8 off
>>> > a CF that is designed to monitor / control a s
At 01:36 PM 4/15/2010, Bernd Walter wrote:
Is the sensor prohibiting the use of USB RS232 in any way?
Just our wallets :) Extra cost to include it and the case would need
to change as well as its in an environment where it can get hit by water.
---Mike
--
B.Walter http://www.bwc
On Wed, Apr 14, 2010 at 09:57:57AM -0400, Mike Tancsa wrote:
> (Tried on questions, but no luck...)
>
>
>
> I have an embedded device (Alix box) that is running RELENG_8 off a
> CF that is designed to monitor / control a serial sensor device. The
> sensor is quite chatty and is always outputi
At 12:59 PM 4/15/2010, Rui Paulo wrote:
If not, maybe there's some way to do this by changing the hints file.
Prior to /boot/loader running, is that even consulted ?
---Mike
Regards,
--
Rui Paulo
Mike Tancsa,
At 12:18 PM 4/15/2010, Julian Elischer wrote:
More of a workaround than a fix, but does it work any better
if you connect the device to com2 instead of com1?
Unfortunately there is only one serial port on the board we are using.
yes but can the bios map it to be com2?
The BIOS (Alix) is ve
On 4/15/10 3:03 AM, Mike Tancsa wrote:
At 12:04 AM 4/15/2010, per...@pluto.rain.com wrote:
Mike Tancsa wrote:
> I have an embedded device (Alix box) that is running RELENG_8 off
> a CF that is designed to monitor / control a serial sensor device.
> The sensor is quite chatty and is always outp
At 12:04 AM 4/15/2010, per...@pluto.rain.com wrote:
Mike Tancsa wrote:
> I have an embedded device (Alix box) that is running RELENG_8 off
> a CF that is designed to monitor / control a serial sensor device.
> The sensor is quite chatty and is always outputing data at 115200.
> The problem is t
Mike Tancsa wrote:
> I have an embedded device (Alix box) that is running RELENG_8 off
> a CF that is designed to monitor / control a serial sensor device.
> The sensor is quite chatty and is always outputing data at 115200.
> The problem is that this will interrupt the boot process.
> I even tr
(Tried on questions, but no luck...)
I have an embedded device (Alix box) that is running RELENG_8 off a
CF that is designed to monitor / control a serial sensor device. The
sensor is quite chatty and is always outputing data at 115200. The
problem is that this will interrupt the boot proc
13 matches
Mail list logo