Re: [AFMUG] PMP450

2014-09-30 Thread Steve Warden via Af
Never looked… I shall try again!

 

Regards

 

Steve Warden

 

Andrews Wireless

671 Durham road 21

Uxbridge

L9P 1R4

 

905 852 8896

 

www.andrewswireless.net

 

From: Af [mailto:af-boun...@afmug.com] On Behalf Of Eric Muehleisen via Af
Sent: September-30-14 9:22 AM
To: af@afmug.com
Subject: Re: [AFMUG] PMP450

 

During a linktest, does the rate-adapt change from 1x?

 

On Tue, Sep 30, 2014 at 7:43 AM, Steve Warden via Af  wrote:

Hi Guys,

 

Just wondering if anybody has any suggestions with something I am seeing on 
PMP5.4, I have two customers close to each other both have signals of 67db (AP 
&SM) both have great link tests but one is showing 8x8x and the other 8x1x, I 
have tried repointing the AP changing the tilt etc… no difference. Both are 
line of sight no trees in the way, we even moved the SM on 8x1x to the other 
side of the house and no change – even tried another SM.

 

This is a replacement for an FSK5.4 and the signals were identical, just this 
8x8x is perplexing me.

 

 

 

Thanks

 

Steve Warden

 

Andrews Wireless

671 Durham road 21

Uxbridge

L9P 1R4

 

905 852 8896  

 

www.andrewswireless.net

 

 



[AFMUG] PMP450

2014-09-30 Thread Steve Warden via Af
Hi Guys,

 

Just wondering if anybody has any suggestions with something I am seeing on
PMP5.4, I have two customers close to each other both have signals of 67db
(AP &SM) both have great link tests but one is showing 8x8x and the other
8x1x, I have tried repointing the AP changing the tilt etc. no difference.
Both are line of sight no trees in the way, we even moved the SM on 8x1x to
the other side of the house and no change - even tried another SM.

 

This is a replacement for an FSK5.4 and the signals were identical, just
this 8x8x is perplexing me.

 

 

 

Thanks

 

Steve Warden

 

Andrews Wireless

671 Durham road 21

Uxbridge

L9P 1R4

 

905 852 8896

 

www.andrewswireless.net

 



[AFMUG] Mean well

2014-09-18 Thread Steve Warden via Af
Hi,

 

I read somewhere that a  meanwell 48/48 (output trimmed to 56v) can be used
to power a PIDU, has anyone tried this? If so what was the part number?

 

We are starting to use the Alpha FMPS 48, on sites with a CMM 48/24 works
great I just need to regulate the PIDU!

 

 

 

 

Regards

 

Steve Warden

 

Andrews Wireless

671 Durham road 21

Uxbridge

L9P 1R4

 

905 852 8896

 

www.andrewswireless.net