Hi - I'm trying to determine a reasonable base before moving onto Bacula
itself... have a look at this, does it make sense?
The autoloader starts off empty. I use mtx to load a tape, and even this
trivial operation returns an error, yet the tape has definately moved!
The autoloader already has the latest firmware :(
[EMAIL PROTECTED] bacula]# mtx -f /dev/sg3 inquiry
Product Type: Medium Changer
Vendor ID: 'HP '
Product ID: '1x8 G2 AUTOLDR '
Revision: '1.30'
Attached Changer API: No
[EMAIL PROTECTED] bacula]# mtx -f /dev/sg3 status
Storage Changer /dev/sg3:1 Drives, 8 Slots ( 0 Import/Export )
Data Transfer Element 0:Empty
Storage Element 1:Full :VolumeTag=VHJ252L2
Storage Element 2:Full :VolumeTag=VHJ251L2
Storage Element 3:Full :VolumeTag=VHJ239L2
Storage Element 4:Full :VolumeTag=VHJ250L2
Storage Element 5:Full :VolumeTag=VHJ246L2
Storage Element 6:Full :VolumeTag=VHJ247L2
Storage Element 7:Full :VolumeTag=VHJ248L2
Storage Element 8:Full :VolumeTag=VHJ249L2
[EMAIL PROTECTED] bacula]# mtx -f /dev/sg3 load 1
Loading media from Storage Element 1 into drive 0...
(.. 15 seconds pass... )
mtx: Request Sense: Long Report=yes
mtx: Request Sense: Valid Residual=no
mtx: Request Sense: Error Code=0 (Unknown?!)
mtx: Request Sense: Sense Key=No Sense
mtx: Request Sense: FileMark=no
mtx: Request Sense: EOM=no
mtx: Request Sense: ILI=no
mtx: Request Sense: Additional Sense Code = 00
mtx: Request Sense: Additional Sense Qualifier = 00
mtx: Request Sense: BPV=no
mtx: Request Sense: Error in CDB=no
mtx: Request Sense: SKSV=no
MOVE MEDIUM from Element Address 1001 to 1 Failed
[EMAIL PROTECTED] bacula]# echo $?
1
[EMAIL PROTECTED] bacula]# mtx -f /dev/sg3 status
mtx: Request Sense: Long Report=yes
mtx: Request Sense: Valid Residual=no
mtx: Request Sense: Error Code=70 (Current)
mtx: Request Sense: Sense Key=Unit Attention
mtx: Request Sense: FileMark=no
mtx: Request Sense: EOM=no
mtx: Request Sense: ILI=no
mtx: Request Sense: Additional Sense Code = 28
mtx: Request Sense: Additional Sense Qualifier = 00
mtx: Request Sense: BPV=no
mtx: Request Sense: Error in CDB=no
mtx: Request Sense: SKSV=no
Mode sense (0x1A) for Page 0x1D failed
Storage Changer /dev/sg3:1 Drives, 8 Slots ( 0 Import/Export )
Data Transfer Element 0:Full (Storage Element 1 Loaded):VolumeTag =
VHJ252L2
Storage Element 1:Empty
Storage Element 2:Full :VolumeTag=VHJ251L2
Storage Element 3:Full :VolumeTag=VHJ239L2
Storage Element 4:Full :VolumeTag=VHJ250L2
Storage Element 5:Full :VolumeTag=VHJ246L2
Storage Element 6:Full :VolumeTag=VHJ247L2
Storage Element 7:Full :VolumeTag=VHJ248L2
Storage Element 8:Full :VolumeTag=VHJ249L2
OS is CentOS 4.5 with all updates applied.
Cheers,
Gavin.
-
This SF.net email is sponsored by: Splunk Inc.
Still grepping through log files to find problems? Stop.
Now Search log events and configuration files using AJAX and a browser.
Download your FREE copy of Splunk now >> http://get.splunk.com/
___
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users