[OSL | CCIE_Voice] B-Channel Maintenance not working properly

2009-02-22 Thread Robert Schuknecht
Hi List,

during my last Remote-Rack Sessions i noticed that the B-Channel Maintenance 
Status Parameter is not workking properly. Always when i configured it and 
restartet the CCM Srevice and the Gateway itself, it is working for some calls. 
And suddenly the Gateway is trying to call out over the not available B-Channels

I configured the Maintenance Status the following ways:

1) S0/ds...@sda000332333241=0001

2) S0/ds...@sda000332333241 = 0001

But both of them did not work. What am i doing wrong here?

/Robert


Re: [OSL | CCIE_Voice] B-Channel Maintenance not working properly

2009-02-22 Thread Ryan Trauernicht
When you try this again what does Perfmon tell you the service of the
channels?
0, 1, 2, 3?

On Sun, Feb 22, 2009 at 11:07 AM, Robert Schuknecht rschukne...@gmx.dewrote:

 Hi List,

 during my last Remote-Rack Sessions i noticed that the B-Channel
 Maintenance Status Parameter is not workking properly. Always when i
 configured it and restartet the CCM Srevice and the Gateway itself, it is
 working for some calls. And suddenly the Gateway is trying to call out over
 the not available B-Channels

 I configured the Maintenance Status the following ways:

 1) S0/ds...@sda000332333241=0001

 2) S0/ds...@sda000332333241 = 0001

 But both of them did not work. What am i doing wrong here?

 /Robert



Re: [OSL | CCIE_Voice] B-Channel Maintenance not working properly

2009-02-22 Thread Frank Costeira


Did you check off status polling on the device config for the circuit?



On Feb 22, 2009, at 12:10 PM, Ryan Trauernicht wrote:

When you try this again what does Perfmon tell you the service of  
the channels?


0, 1, 2, 3?

On Sun, Feb 22, 2009 at 11:07 AM, Robert Schuknecht rschukne...@gmx.de 
 wrote:

Hi List,

during my last Remote-Rack Sessions i noticed that the B-Channel  
Maintenance Status Parameter is not workking properly. Always when i  
configured it and restartet the CCM Srevice and the Gateway itself,  
it is working for some calls. And suddenly the Gateway is trying to  
call out over the not available B-Channels


I configured the Maintenance Status the following ways:

1) S0/ds...@sda000332333241=0001

2) S0/ds...@sda000332333241 = 0001

But both of them did not work. What am i doing wrong here?

/Robert





Re: [OSL | CCIE_Voice] B-Channel Maintenance not working properly

2009-02-22 Thread Vik Malhi
I've battled with this service parameter for over 5 years. It doesn't work
properly- I would use Top-Down with a fractional PRI.

But if you are trying to get it working you must ensure that you Enable
Status Poll on the gateway page. Also- you could try including a space
after every 4 bits (although I'm told that is not necessary, that is what I
have always done since the example show this).

So try this : (+ Enable Status Poll).

S0/ds...@sda000332333241=0001     
 
-- 
Vik Malhi ­ CCIE #13890, CCSI #31584
Senior Technical Instructor - IPexpert, Inc.

Telephone: +1.810.326.1444
Fax: +1.810.454.0130
Mailto: vma...@ipexpert.com


Join our free online support and peer group communities:
http://www.IPexpert.com/communities
IPexpert - The Global Leader in Self-Study, Classroom-Based, Video-On-Demand
and Audio Certification Training Tools for the Cisco CCIE RS Lab, CCIE
Security Lab, CCIE Service Provider Lab , CCIE Voice Lab and CCIE Storage
Lab Certifications.







 From: Robert Schuknecht rschukne...@gmx.de
 Date: 22 Feb 2009 18:07:17 +0100
 To: OSL Group ccie_voice@onlinestudylist.com
 Subject: [OSL | CCIE_Voice] B-Channel Maintenance not working properly
 
 Hi List,
 
 during my last Remote-Rack Sessions i noticed that the B-Channel Maintenance
 Status Parameter is not workking properly. Always when i configured it and
 restartet the CCM Srevice and the Gateway itself, it is working for some
 calls. And suddenly the Gateway is trying to call out over the not available
 B-Channels
 
 I configured the Maintenance Status the following ways:
 
 1) S0/ds...@sda000332333241=0001
 
 2) S0/ds...@sda000332333241 = 0001
 
 But both of them did not work. What am i doing wrong here?
 
 /Robert




Re: [OSL | CCIE_Voice] B-Channel Maintenance not working properly

2009-02-22 Thread Hardesty, Scott
 Agreed!  It does not work well at all.   I typically will have calls
incoming / outgoing the 6608 PRI and make a call 1 hour later to find
that the call fails.  After a fitting Microsoft salute (reset), the call
goies through... 



 
Scott Hardesty | Solutions Engineer | MidAtlantic | Presidio Networked Solutions
7601 Ora Glen Drive, Suite 100, Greenbelt, MD  20770 | 
mailto:sharde...@presidio.com
D: 301.313.2041 | C: 443.789.1219 | http://www.presidio.com/

 
-Original Message-

From: ccie_voice-boun...@onlinestudylist.com
[mailto:ccie_voice-boun...@onlinestudylist.com] On Behalf Of Vik Malhi
Sent: Sunday, February 22, 2009 12:33 PM
To: Robert Schuknecht; OSL Group
Subject: Re: [OSL | CCIE_Voice] B-Channel Maintenance not working
properly

I've battled with this service parameter for over 5 years. It doesn't
work
properly- I would use Top-Down with a fractional PRI.

But if you are trying to get it working you must ensure that you Enable
Status Poll on the gateway page. Also- you could try including a
space
after every 4 bits (although I'm told that is not necessary, that is
what I
have always done since the example show this).

So try this : (+ Enable Status Poll).

S0/ds...@sda000332333241=0001     
 
-- 
Vik Malhi - CCIE #13890, CCSI #31584
Senior Technical Instructor - IPexpert, Inc.

Telephone: +1.810.326.1444
Fax: +1.810.454.0130
Mailto: vma...@ipexpert.com


Join our free online support and peer group communities:
http://www.IPexpert.com/communities
IPexpert - The Global Leader in Self-Study, Classroom-Based,
Video-On-Demand
and Audio Certification Training Tools for the Cisco CCIE RS Lab, CCIE
Security Lab, CCIE Service Provider Lab , CCIE Voice Lab and CCIE
Storage
Lab Certifications.







 From: Robert Schuknecht rschukne...@gmx.de
 Date: 22 Feb 2009 18:07:17 +0100
 To: OSL Group ccie_voice@onlinestudylist.com
 Subject: [OSL | CCIE_Voice] B-Channel Maintenance not working properly
 
 Hi List,
 
 during my last Remote-Rack Sessions i noticed that the B-Channel
Maintenance
 Status Parameter is not workking properly. Always when i configured it
and
 restartet the CCM Srevice and the Gateway itself, it is working for
some
 calls. And suddenly the Gateway is trying to call out over the not
available
 B-Channels
 
 I configured the Maintenance Status the following ways:
 
 1) S0/ds...@sda000332333241=0001
 
 2) S0/ds...@sda000332333241 = 0001
 
 But both of them did not work. What am i doing wrong here?
 
 /Robert