[ccp4bb] Call for MX-beamtime at HZB-BESSY II, Berlin, period: July/2010 - June/2011, Deadline: March 1. 2010
Next MX-proposal application deadline: March 1, 2010 See: http://www.bessy.de/boat/ We kindly request new MX-proposals for beamtime applications for the next beamtime period. In order to apply for beamtime, please register at the HZB on-line access tool BOAT (http://www.bessy.de/boat/) and submit a new beamtime application proposal. HZB provides beamtime at the MX-beamlines 14.1 and 14.2. The requested beamtime is granted based on the reviewed proposal and reports from previous research activities at BESSY II. Results from previous projects stated in the Experimental Reports will affect the chances for future beamtimes significantly. Please make sure to include them if available. Experimental setup: BL14.1 setup: - Photonflux: 1.4x10¹¹ Phot/sx100mAx0.05%BW at sample position (0.1-20 sec exposure time per frame) - User defined beam shaping from 30µm-100µm diameter possible - MX-225 X-ray detector, 92mm-720mm max. distance from the sample - Microdiffractometer (MD2) with Mini-kappa goniometer MK3 (STAC controlled) - Automatic sample changer (CATS), 90 sample storage capacity (SPINE-Pin EMBL sample magazine compatibility) - 96-well crystallization plate scanning (test phase) - Dedicated eight-core XEON-CPU server, with fibre channel SAN up-link data processing environment - EDNA installed and available - Common MX software installed including HKL2000, XDS, IMOSFLM, CCP4, Phenix, SHELXC-E, etc. - Automated data processing with ixds and xdsi available - Remotely controlled cryo-shutter for crystal annealing - Bruker AXS X-Flash XRF detector We are offering the hard- and software environment for carrying out UVRIP experiments at BL14.1. For further information, please visit: http://www.helmholtz-berlin.de/forschung/funkma/soft-matter/forschung/bessy-mx/beamlines/bl14-1/hardware/uvrip_en.html BL14.2 setup: - Photonflux: 2x10¹¹ Phot/sx100mAx0.05%BW at sample position (0.1-20 sec exposure time per frame) - MX-225 X-ray detector, 45mm-380mm distance from the sample, 30 deg 2-Theta possible - mardtb goniometer installed - Dedicated eight-core XEON-CPU server, with fibre channel SAN up-link data processing environment - EDNA installed and available - Common MX software installed including HKL2000, XDS, IMOSFLM, CCP4, Phenix, SHELXC-E, etc. - Automated data processing with ixds and xdsi available - Remotely controlled cryo-shutter for crystal annealing - Bruker AXS X-Flash XRF detector - Pressure chamber for noble gas derivatization (Xe, Kr available upon request) - Ultra high performance stereo microscope Leica M205A, 20-255x zoom, 8 Mpixel CCD-camera Please visit our web page www.helmholtz-berlin.de/bessy-mx to gain updated information about our experimental setup and other requirements. Uwe Mueller, Manfred Weiss and the HZB BESSY-MX group -- Dr. Uwe Mueller Makromolekulare Kristallographie (BESSY-MX) / Group leader Elektronenspeicherring BESSY II Albert-Einstein-Str. 15, D-12489 Berlin, Germany Fon: +49 30 6392 4974 Fax: +49 30 6392 4975 url: http://www.helmholtz-berlin.de/bessy-mx u...@bessy.de http://www.helmholtz-berlin.de/bessy-mx%3Ewww.helmholtz-berlin.de/bessy-mx%3C/a%3E%3Cbr%3E%0A%0Aemail:%3Cbr%3E%0A%3Ca%20href= u...@helmholtz-berlin.de mailto:u...@helmholtz-berlin.de /Helmholtz-Zentrum Berlin für Materialien und Energie GmbH Hahn-Meitner-Platz 1, 14109 Berlin Vorsitzender des Aufsichtsrats: Prof. Dr. Dr. h.c. mult. Joachim Treusch Stellvertretende Vorsitzende: Dr. Beatrix Vierkorn-Rudolph Geschäftsführer: Prof. Dr. Anke Rita Kaysser-Pyzalla, Prof. Dr. Dr. h.c. Wolfgang Eberhardt, Dr. Ulrich Breuer Sitz der Gesellschaft: Berlin Handelsregister: AG Charlottenburg, 89 HRB 5583 /
[ccp4bb] Postdoctoral Research Assistant at the Humboldt University Berlin, Germany
The Humboldt-University Berlin (HU-Berlin) is looking for a Postdoctoral Research Assistant for Macromolecular Structure and Interaction to support the operation of the MX-beamlines located at the BESSY II storage ring (headed by Dr. Uwe Müller, BESSY/HZB) and to conduct research at the HU-Berlin under the guidance of Prof. Dr. Holger Dobbek. BESSY/HZB collaborates with the HU-Berlin in operating three state-of-the-art experimental stations for bio-macromolecular crystallography at one of the world's most modern synchrotron radiation sources for VUV and soft X-rays. Description: The successful candidate will support MX-beamline users in data collection and analysis, participate in the development, implementation and commissioning of MX-beamline instrumentation, and pursue his/her own research in the field of macromolecular structure and function of cofactor containing enzymes. Requirements: Applicants should hold a Ph.D. in either biological, chemical or physical sciences and have a strong background in all aspects of bio-macromolecular crystallography, in particular in the use of the relevant computer programs. The position also requires the documented ability to conduct independent research as well as excellent communication and interpersonal skills. Salary: The salary will be based on German Vgr. IIa- BAT-O nach AnwTV HU. Entry: The position is available immediately. Limitation: We are initially offering a three-year contract with the possibility of an extension. Disabled persons with same qualification are given preference. Applications under the reference number AN/147/09 should include a cover letter, curriculum vita, a publication list, and a detailed summary of research experience and interests. Electronic submissions organized within a single pdf-file and inquiries may be addressed to: u...@bessy.de -- Dr. Uwe Mueller Makromolekulare Kristallographie (BESSY-MX) / Group leader Elektronenspeicherring BESSY II Albert-Einstein-Str. 15, D-12489 Berlin, Germany Fon: +49 30 6392 4974 Fax: +49 30 6392 4975 u...@bessy.de mailto:u...@bessy.de u...@helmholtz-berlin.de mailto:u...@helmholtz-berlin.de /Helmholtz-Zentrum Berlin für Materialien und Energie GmbH Hahn-Meitner-Platz 1, 14109 Berlin Vorsitzende des Aufsichtsrates: Dr. Beatrix Vierkorn-Rudolph Stellvertretende Vorsitzende: Dr. Jutta Koch-Unterseher Gesch?ftsführer: Prof. Dr. Anke Rita Kaysser-Pyzalla, Prof. Dr. Dr. h.c. Wolfgang Eberhardt, Dr. Ulrich Breuer Sitz der Gesellschaft: Berlin Handelsregister: AG Charlottenburg, 89 HRB 5583 /
[ccp4bb] Postdoctoral Research Assistant at the Max-Delbrück-Centrum (MDC) Berlin, Germany
The Max-Delbrück-Centrum (MDC) in Berlin-Buch is looking for a Postdoctoral Research Assistant for Macromolecular Structure and Interaction to support the operation of the MX beamlines located at the BESSY II storage ring (headed by Dr. Uwe Müller, BESSY/HZB) and to conduct research at the MDC under the guidance of Dr. Manfred S. Weiss (BESSY/HZB) and Prof. Dr. Udo Heinemann (MDC). BESSY/HZB collaborates with the MDC in Berlin-Buch in operating three state-of-the-art experimental stations for bio-macromolecular crystallography at one of the world’s most modern synchrotron radiation sources for VUV and soft X-rays. Description: The successful candidate will support MX beamline users in data collection and analysis, participate in the development, implementation and commissioning of MX beamline instrumentation, and pursue his/her own research in the fields of Macromolecular Structure and Interaction. Requirements: Applicants should hold a Ph.D. in either biological, chemical or physical sciences and have a strong background in all aspects of bio-macromolecular crystallography, in particular in the use of the relevant computer programs. The position also requires the documented ability to conduct independent research as well as excellent communication and interpersonal skills. Salary: The salary will be based on German Federal TVÖD E13. Entry: The position is available immediately. Limitation: We are initially offering a three-year contract with the possibility of an extension. Disabled persons with same qualification are given preference. Disabled persons with same qualification are given preference. Applications under the reference number 10129/2009 should include a cover letter, curriculum vita, a publication list, and a detailed summary of research experience and interests. Electronic submissions organized within a single pdf-file and inquiries may be addressed to: u...@bessy.de -- Dr. Uwe Mueller Makromolekulare Kristallographie (BESSY-MX) / Group leader Institut F-I2 Elektronenspeicherring BESSY II Albert-Einstein-Str. 15, D-12489 Berlin, Germany Fon: +49 30 6392 4974 Fax: +49 30 6392 4975 url: http://www.helmholtz-berlin.de/bessy-mx email-bessy: u...@bessy.de email-hzb: u...@helmholtz-berlin.de Helmholtz-Zentrum Berlin für Materialien und Energie GmbH Vorsitzende des Aufsichtsrates: Dr. Beatrix Vierkorn-Rudolph Stellvertretende Vorsitzende: Dr. Jutta Koch-Unterseher Geschäftsführer: Prof. Dr. Anke Rita Kaysser-Pyzalla, Prof. Dr. Dr. h.c. Wolfgang Eberhardt, Dr. Ulrich Breuer Sitz der Gesellschaft: Berlin Handelsregister: AG Charlottenburg, 89 HRB 5583
[ccp4bb] Call for MX-beamtime at HZB-BESSY-II, Berlin, period: January/2010 - December/2010, Deadline: September 1. 2009
Next MX-proposal application deadline: September 1, 2009 See: http://www.bessy.de/boat/www/ We kindly request new MX-proposals for beamtime applications for the next beamtime period. In order to apply for beamtime, please register at the BESSY on-line access tool BOAT (http://www.bessy.de/boat/www/) and submit a new beamtime application proposal. It is possible to propose a number of projects within the proposal lifetime of one year. HZB-BESSY provides beamtime at the MX-beamlines 14.1 and 14.2. The requested beamtime is granted based on the reviewed proposal and reports from previous research activities at BESSY. Results from previous projects stated in the Experimental Reports will affect the chances for future beamtimes significantly. Please make sure to include them if available. New experimental setup: We are offering the hard- and software environment for carrying out UVRIP experiments at BL14.1. For further information, please visit: http://www.helmholtz-berlin.de/forschung/funkma/soft-matter/bessy-mx/beamlines/bl14-1/hardware/uvrip_en.html The upgraded experimental station at BL14.1. has the following key features: - Photonflux: 2x10¹¹ Phot/sx100mAx0.05%BW at sample position (0.11-20 sec exposure time per frame) - MX-225 X-ray detector, 720mm max. distance from the sample, 30 deg max. 2Theta - Microdiffractometer (MD2) with Mini-kappa goniometer MK3 - Automatic sample changer (CATS), 90 sample storage capacity (SPINE-Pin EMBL sample magazine compatibility) - 96-well crystallization plate scanning (test phase) - New high performance data processing environment - EDNA, STAC installed and availalbe - Bruker AXS X-Flash XRF detector on BL14.1+2 -MX-225 X-ray detector at BL14.2 Please visit our web page www.helmholtz-berlin.de/bessy-mx to gain updated information about our experimental setup and other requirements. Uwe Mueller the HZB BESSY-MX group -- Dr. Uwe Mueller Makromolekulare Kristallographie (BESSY-MX) / Group leader Abteilung F-I2 Elektronenspeicherring BESSY II Albert-Einstein-Str. 15, D-12489 Berlin, Germany Fon: +49 30 6392 4974 Fax: +49 30 6392 4975 email-bessy: u...@bessy.de email-hzb: u...@helmholtz-berlin.de Helmholtz-Zentrum Berlin für Materialien und Energie GmbH Vorsitzende des Aufsichtsrates: Dr. Beatrix Vierkorn-Rudolph Stellvertretende Vorsitzende: Dr. Jutta Koch-Unterseher Geschäftsführer: Prof. Dr. Anke Rita Pyzalla, Prof. Dr. Dr. h.c. Wolfgang Eberhardt, Dr. Ulrich Breuer Sitz der Gesellschaft: Berlin Handelsregister: AG Charlottenburg, 89 HRB 5583
[ccp4bb] MX-beamtime at BESSY-Berlin, period: July/2009 - June/2010, Deadline March 1, 2009
Next MX-proposal application deadline: March 1, 2009 See: http://www.bessy.de/boat/www/ We kindly request new MX-proposals for beamtime applications for the next beamtime period. In order to apply for beamtime, please register at the BESSY on-line access tool BOAT (http://www.bessy.de/boat/www/) and submit a new beamtime application proposal. It is possible to propose a number of projects within the proposal lifetime of one year. BESSY provides beamtime at the MX-beamlines 14.1 and 14.2. The requested beamtime is granted based on the reviewed proposal and reports from previous research activities at BESSY. Results from previous projects stated in the Experimental Reports will affect the chances for future beamtimes significantly. Please make sure to include them if available. New experimental setup: We are offering the hard- and software environment for carrying out UVRIP experiments at BL14.2. For further information, please visit: http://www.mx.bessy.de/userguide/beamlines/bl1/uvrip.shtml The upgraded experimental station at BL14.1. has the following key features: - Photonflux: 2x10¹¹ Phot/sx100mAx0.05%BW at sample position (1-20 sec exposure time per frame) - MX-225 X-ray detector, 720mm max. distance from the sample, 30 deg max. 2Theta - Microdiffractometer (MD2) with Mini-kappa goniometer MK3 - Automatic sample changer (CATS), 90 sample storage capacity (SPINE-Pin EMBL sample magazine compatibility) - 96-well crystallization plate scanning (test phase) - New high performance data processing environment - Bruker AXS X-Flash XRF detector on BL14.1+2 -MX-225 X-ray detector at BL14.2 Please visit our web page (http://www.mx.bessy.de) to gain updated information about our experimental setup and other requirements. Uwe Mueller the BESSY-MX group -- Dr. Uwe Mueller Makromolekulare Kristallographie (BESSY-MX) / Group leader Elektronenspeicherring BESSY II Albert-Einstein-Str. 15, D-12489 Berlin, Germany Fon: +49 30 6392 4974 Fax: +49 30 6392 4975 u...@bessy.de mailto:u...@bessy.de u...@helmholtz-berlin.de mailto:u...@helmholtz-berlin.de Helmholtz-Zentrum Berlin für Materialien und Energie GmbH Glienicker Straße 100, 14109 Berlin Vorsitzende des Aufsichtsrates: Dr. Beatrix Vierkorn-Rudolph Stellvertretende Vorsitzende: Dr. Jutta Koch-Unterseher Geschäftsführer: Prof. Dr. Anke Rita Pyzalla, Prof. Dr. Dr. h.c. Wolfgang Eberhardt, Dr. Ulrich Breuer Sitz der Gesellschaft: Berlin Handelsregister: AG Charlottenburg, 89 HRB 5583 Information: Durch die Fusion mit dem ehemaligen Hahn-Meitner-Institut (HMI) ist BESSY nun Teil des neuen Helmholtz-Zentrum Berlin für Materialien und Energie (HZB). By the merger with the former Hahn-Meitner-Institut (HMI), BESSY became part of the new Helmholtz-Zentrum Berlin für Materialien und Energie (HZB). Disclaimer automatically attached by the E-Mail Security Appliance mail0.bessy.de 02/04/09 at Helmholtz-Zentrum Berlin GmbH.
[ccp4bb] Open vacancy : Post Doctoral Research Assistant FU-Berlin, Germany
The Helmholtz Association, the Freie Universität Berlin and the Humboldt Universität zu Berlin are operating three experimental stations for bio-macromolecular crystallography at BESSY, one of the world's most modern synchrotron radiation sources for VUV and soft X-rays. The Department of Biology, Chemistry and Pharmacy of the Freie Universität Berlin is seeking a Post Doctoral Research Assistant to support operation of the BESSY bio-macromolecular crystallography beamlines (headed by Dr. Uwe Mueller), participate in graduate student education and to conduct research at the Laboratory for Structural Biochemistry (headed by Prof. Dr. Markus Wahl) of the Freie Universität Berlin. We are initially offering a three-year contract with the possibility for an extension. The salary will be based on German Federal BAT-IIa (i.d.F.d. Anw.-TV FUB). The position is immediately available. The successful candidate will support beamline users in data collection and analysis, participate in the development, implementation and commissioning of beamline instrumentation, collaborate closely with the structural biochemistry community in Berlin and pursue his/her own research program in the fields of RNA-based macromolecular machines or membrane receptors. Applicants should hold a Ph.D. in the biological, chemical or physical sciences and have a strong background in all aspects of bio-macromolecular crystallography, in particular in the use of the relevant computer programs. The position also requires the documented ability to conduct independent research as well as excellent communication and interpersonal skills. Please send applications (CV, list of publications, .pdf-file format) in electronic form until February 12, 2009, using the reference number 21340200/02/09 to Dr. Uwe Mueller -- Dr. Uwe Mueller Makromolekulare Kristallographie (BESSY-MX) / Group leader Elektronenspeicherring BESSY II Albert-Einstein-Str. 15, D-12489 Berlin, Germany Fon: +49 30 6392 4974 Fax: +49 30 6392 4975 u...@bessy.de mailto:u...@bessy.de u...@helmholtz-berlin.de mailto:u...@helmholtz-berlin.de Helmholtz-Zentrum Berlin für Materialien und Energie GmbH Glienicker Straße 100, 14109 Berlin Vorsitzende des Aufsichtsrates: Dr. Beatrix Vierkorn-Rudolph Stellvertretende Vorsitzende: Dr. Jutta Koch-Unterseher Geschäftsführer: Prof. Dr. Anke Rita Pyzalla, Prof. Dr. Michael Steiner, Dr. Ulrich Breuer Sitz der Gesellschaft: Berlin Handelsregister: AG Charlottenburg, 89 HRB 5583 Information: Durch die Fusion mit dem ehemaligen Hahn-Meitner-Institut (HMI) ist BESSY nun Teil des neuen Helmholtz-Zentrum Berlin für Materialien und Energie (HZB). Die Fusion wird im Januar 2009 vollzogen sein. By the merger with the former Hahn-Meitner-Institut (HMI), BESSY became part of the new Helmholtz-Zentrum Berlin für Materialien und Energie (HZB). The merger will be completed by January 2009. Disclaimer automatically attached by the E-Mail Security Appliance mail0.bessy.de 01/24/09 at Helmholtz-Zentrum Berlin GmbH.
[ccp4bb] Winter school on soft X-rays in Macromolecular Crystallography
The registration deadline is approaching at January 15th. For those of you who are interested within this field, a limited number of additional participants can still be accepted at this venue. Here are some details: Winter School on Soft X-rays in Macromolecular Crystallography, February 18-20th, 2009 at BESSY-II, Helmholtz-Zentrum Berlin für Materialien und Energie. The third Winter School on Soft X-rays in Macromolecular Crystallography (after Seefeld in 2006 and Bressanone in 2003) will bring together experts from different fields, which are key-players in the developments and further utilization of Soft X-ray applications in structural biology with the users of this modern methodology. The three days school will cover the following topics: (1) the design of soft X-ray sources, (2) the design of beamlines optimized for soft X-ray research, (3) new detectors, (4) optimal data collection procedures for soft X-ray diffraction, (5) new derivatization methods of biological macromolecules, (6) long wavelength approaches to increase the anomalous scattering of sulfur and other natively occurring anomalous scatterers, (7) treatment of soft X-ray data, (from processing towards the phasing and phase improvements), (8) radiation damage and its utilization to gain structural information. Scientific contributions from participants with examples of Soft X-ray related structural studies will be included in the program as well. The following speakers already agreed to participate: . George Sheldrick (Universität Göttingen) . Gerard Bricogne (Global Phasing, Cambridge) . Elspeth Garman (University of Oxford) . Bram Schierbeck (Bruker, Delft) . Christoph Müller-Dieckmann (ESRF, Grenoble) . Andy Thompson / Pierre Legrande (Soleil, Paris) . Armin Wagner (DIAMOND, Didcot) . Gwyndaf Evans (DIAMOND, Didcot) . BC Wang (University of Georgia, Athens) . Vincent Olieric (SLS, Villingen) . Kristina Djinovic Carugo (University Vienna) . Manfred S. Weiss (EMBL Hamburg) . Raymond B.G. Ravelli (Utrecht University) Scientific Organizers: Uwe Mueller (BESSY-II, Berlin), Manfred Weiss (EMBL Hamburg), Kristina Djinovic Carugo (University Vienna) In order to register and for further information, please visit the workshop web-page: http://www.helmholtz-berlin.de/aktuell/events/winter-school-mx/ On behalf of the organizers, Uwe Mueller -- Dr. Uwe Mueller Makromolekulare Kristallographie (BESSY-MX) / Group leader Elektronenspeicherring BESSY II Albert-Einstein-Str. 15, D-12489 Berlin, Germany Fon: +49 30 6392 4974 Fax: +49 30 6392 4975 u...@bessy.de mailto:u...@bessy.de u...@helmholtz-berlin.de mailto:u...@helmholtz-berlin.de /Helmholtz-Zentrum Berlin für Materialien und Energie GmbH Vorsitzende des Aufsichtsrates: Dr. Beatrix Vierkorn-Rudolph, Geschäftsführer: Prof. Dr. Anke Rita Pyzalla, Prof. Dr. Dr. h.c. Wolfgang Eberhardt, Dr. Ulrich Breuer Sitz Berlin, AG Charlottenburg, 89 HRB 5583/ Helmholtz-Zentrum Berlin für Materialien und Energie GmbH Glienicker Straße 100, 14109 Berlin Vorsitzende des Aufsichtsrates: Dr. Beatrix Vierkorn-Rudolph Stellvertretende Vorsitzende: Dr. Jutta Koch-Unterseher Geschäftsführer: Prof. Dr. Anke Rita Pyzalla, Prof. Dr. Michael Steiner, Dr. Ulrich Breuer Sitz der Gesellschaft: Berlin Handelsregister: AG Charlottenburg, 89 HRB 5583 Information: Durch die Fusion mit dem ehemaligen Hahn-Meitner-Institut (HMI) ist BESSY nun Teil des neuen Helmholtz-Zentrum Berlin für Materialien und Energie (HZB). Die Fusion wird im Januar 2009 vollzogen sein. By the merger with the former Hahn-Meitner-Institut (HMI), BESSY became part of the new Helmholtz-Zentrum Berlin für Materialien und Energie (HZB). The merger will be completed by January 2009. Disclaimer automatically attached by the E-Mail Security Appliance mail0.bessy.de 01/09/09 at Helmholtz-Zentrum Berlin GmbH.
[ccp4bb] Workshop -Neutrons and X-rays meet biology- 25-27 February 2009 / Second Circular
Dear all, You are cordially invited to the *Workshop Neutrons and X-rays meet biology * 25-27 February, 2009 Helmholtz Zentrum Berlin für Materialien und Energie Deadline for abstract submission: 31 December, 2008 Registration fees: 140 euros (including, coffee breaks, meals, workshop dinner, booklet of abstracts). For further information and registration, please visit the workshop's website: *http://www.helmholtz-berlin.de/events/biology/* We look forward to welcoming you in Berlin on 25 February, 2009. Marie-Claire Bellissent-Funel, Uwe Mueller, Roland Steitz (Workshop chairs) -- ___ Dr. Uwe Müller BESSY-MX group BESSY GmbH Albert-Einstein-Straße-15 D-12489 Berlin Phone: +49-(0)30-6392 4974 Fax : +49-(0)30-6392 4975 email: [EMAIL PROTECTED] url : http://www.psf.bessy.de BESSY GmbH - Mitglied der Leibniz Gemeinschaft Vorsitzender des Aufsichtsrates: Prof. Dr. Dr. h.c. mult Joachim Treusch Geschäftsführer: Prof. Dr. Dr. h.c. Wolfgang Eberhardt, Prof. Dr.Eberhard Jaeschke Sitz Berlin, AG Charlottenburg, HRB 14635
Re: [ccp4bb] foam dewar usage ?
we have those 800ml dewars at our beamlines and I would not by them anymore. The green lid is not really insulating and the working area inside the cylinder is too small. In order to use it for sample manipulations, one has to fill it completely with LN2, which will cause uncontrolled LN2 spilling while moving the dewar. I personally prefer the good old stainless steel dewars together with a self-made metal lid. Best regards, Uwe Jean-Baptiste REISER wrote: Dear all, Does anyone in the biocrystallogaphy community use foam dewars for handly liquid nitrogen and freezing/manipulating frozen protein crystals ? We are interested in the following dewar package from Hampton Research : http://www.hamptonresearch.com/products/ProductDetails.aspx?cid=24sid=187pid=559 But before purchasing, we would like to have any comments on the advantages and drawbacks from people who already tried those dewars. Thanks in advance for your help and advices. -- *Dr JEAN-BAPTISTE REISER - Chargé de recherche CNRS* ** *Laboratoire de Cristallographie et Cristallogenèse des Protéines (LCCP)* *et Partnership for Structural Biology (PSB)* *Institut de Biologie Structural Jean-Pierre Ebel (IBS) - CNRS - CEA - UJF* 41, rue Jules Horowitz 38027 Grenoble - France Phone : +33 (0)4 76 20 94 49 Fax : +33 (0)4 76 20 94 80 E-mail : [EMAIL PROTECTED] Web sites : http://www.ibs.fr ; http://psb.esrf.fr ** -- ___ Dr. Uwe Müller BESSY-MX group BESSY GmbH Albert-Einstein-Straße-15 D-12489 Berlin Phone: +49-(0)30-6392 4974 Fax : +49-(0)30-6392 4975 email: [EMAIL PROTECTED] url : http://www.psf.bessy.de BESSY GmbH - Mitglied der Leibniz Gemeinschaft Vorsitzender des Aufsichtsrates: Prof. Dr. Dr. h.c. mult Joachim Treusch Geschäftsführer: Prof. Dr. Dr. h.c. Wolfgang Eberhardt, Prof. Dr.Eberhard Jaeschke Sitz Berlin, AG Charlottenburg, HRB 14635
Re: [ccp4bb] test data sets part II...
EMBL-Hamburg and BESSY have put a number of interesting data-sets including tutorial materials for data processing and phase determination made available recently. You can download the data from both locations: http://www.mx.bessy.de/xray_tutorial.shtml http://webapps.embl-hamburg.de/Xray_Tutorial/ Uwe -- ___ Dr. Uwe Mueller AG Makromolekulare Kristallographie BESSY GmbH Albert-Einstein-Straße 15 D-12489 Berlin Phone: +49-(0)30-6392 4974 Fax : +49-(0)30-6392 4975 email: [EMAIL PROTECTED] url : http://www.mx.bessy.de
[ccp4bb] MX-beamtime at BESSY-Berlin, period: January/2009 - June/2009
Next MX-proposal application deadline: August 15th 2008 See: http://www.bessy.de/boat/www/ We kindly request MX-proposals for beamtime applications for the next beamtime period. In order to apply for beamtime, please register at the BESSY on-line access tool BOAT (http://www.bessy.de/boat/www/) and submit a new beamtime application proposal. It is possible to propose a number of projects within the proposal lifetime of one year. BESSY provides beamtime at the MX-beamlines 14.1 and 14.2. The requested beamtime is granted based on the reviewed proposal and reports from previous research activities at BESSY. New experimental setup: We are offering the hard- and software environment for carrying out UVRIP experiments at BL14.2. For further information, please visit: http://www.psf.bessy.de/userguide/beamlines/bl1/uvrip.shtml In July 2008 we did start the user operation of the completely upgraded experimental station at BL14.1. Key features are: - Photonflux: 2x10¹¹ Phot/sx100mAx0.05%BW at sample position (1-20 sec exposure time per frame) - MX-225 X-ray detector, 720mm max. distance from the sample, 30 deg max. 2Theta - Microdiffractometer (MD2) with Mini-kappa goniometer MK3 - Automatic sample changer (CATS), 90 sample storage capacity (SPINE-Pin EMBL sample magazine compatibility, available in Fall 2008) - 96-well crystallization plate scanning - New high performance data processing environment - Bruker AXS X-Flash XRF detector on BL14.1+2 -MX-225 X-ray detector at BL14.2 Please visit our web page (http://www.psf.bessy.de) to gain updated information about our experimental setup and other requirements. Uwe Mueller the BESSY-MX group -- ___ Dr. Uwe Müller BESSY-MX group BESSY GmbH Albert-Einstein-Straße-15 D-12489 Berlin Phone: +49-(0)30-6392 4974 Fax : +49-(0)30-6392 4975 email: [EMAIL PROTECTED] url : http://www.psf.bessy.de BESSY GmbH - Mitglied der Leibniz Gemeinschaft Vorsitzender des Aufsichtsrates: Prof. Dr. Dr. h.c. mult Joachim Treusch Geschäftsführer: Prof. Dr. Dr. h.c. Wolfgang Eberhardt, Prof. Dr.Eberhard Jaeschke Sitz Berlin, AG Charlottenburg, HRB 14635
[ccp4bb] Call for MX-beamtime proposals for BESSY-Berlin, Deadline: February 15th 2008
MX-beamtime at BESSY-Berlin, period: July/2008 - June/2009 Next MX-proposal application deadline: February 15th 2008 See: http://www.bessy.de/boat/www/ We kindly request MX-proposals for beamtime applications for the next beamtime period. In order to apply for beamtime, please register at the BESSY on-line access tool BOAT (http://www.bessy.de/boat/www/) and submit a new beamtime application proposal. It is possible to propose a number of projects within the proposal lifetime of one year. BESSY provides beamtime at the MX-beamlines 14.1 and 14.2. The requested beamtime is granted based on the reviewed proposal and reports from previous research activities at BESSY. New experimental setup: We are offering the hard- and software environment for carrying out UVRIP experiments at BL14.1. For further information, please visit: http://www.psf.bessy.de/userguide/beamlines/bl1/uvrip.shtml Starting from Summer 2008, the completely upgraded experimental station at BL14.1 will be available to the users. Key features are: - Photonflux: 2x10¹¹ Phot/sx100mAx0.05%BW at sample position (1-20 sec exposure time per frame) - Marmosaic 225mm X-ray detector (already available) , 700mm max. distance towards the sample, 30 deg max. 2Theta - Microdiffractometer (MD2) with Mini-kappa goniometer - Automatic sample changer (CATS), 90 sample storage capacity (SPINE-Pin EMBL sample magazine compatibility) - 96-well crystallization plate scanning - New high performance data processing environment (already available) -Marmosaic 225mm X-ray detector at BL14.2 (May 2008) Please visit our web page (http://www.psf.bessy.de) to gain updated information about our experimental setup and other requirements. Uwe Mueller the BESSY-MX group -- ___ Dr. Uwe Müller BESSY-MX group BESSY GmbH Albert-Einstein-Straße-15 D-12489 Berlin Phone: +49-(0)30-6392 4974 Fax : +49-(0)30-6392 4975 email: [EMAIL PROTECTED] url : http://www.psf.bessy.de BESSY GmbH - Mitglied der Leibniz Gemeinschaft Vorsitzender des Aufsichtsrates: Prof. Dr. Dr. h.c. mult Joachim Treusch Geschäftsführer: Prof. Dr. Dr. h.c. Wolfgang Eberhardt, Prof. Dr.Eberhard Jaeschke Sitz Berlin, AG Charlottenburg, HRB 14635