Re: Problems com class word.application
This article may help you http://www.cfcomet.com/general_COM/OLEView/ -From the desk of Joshua O'Connor-Rose (aka Whifflebat) -All is Good >From: <[EMAIL PROTECTED]> >Reply-To: [EMAIL PROTECTED] >To: CF-Talk <[EMAIL PROTECTED]> >Subject: Re: Problems com class word.application >Date: Tue, 4 Feb 2003 15:21:13 -0500 > >I am facing a similar problem, I think, in that I can't figure out what to >use for the "class" attribute. > >In ASP I would just use the CLSID, but OLEView doesn't give anything for >class name for the COM (ocx) that I'm trying to use. > > >- Original Message - >From: "Joshua O'Connor-Rose" <[EMAIL PROTECTED]> > > > > Trying out a couple of Word2HTML tools > > They finaly get a copy of Word2000 installed and I set up. > > Word2HTML on the server (author Randy Mayes) > > > > This gives me: > > The error occurred while processing an element with a general identifier >of > > (CFX_WORD2HTML), occupying document position (115:3) to (121:19) in the > > template file D:\applications\CFusion\CustomTags\Word2HTML.cfm. > > > > (That would be in the custom tag itself) > > > > So I figure I'll debug the thing by creating objects myself. > > Using word2HTML.cfm > > (authors Greg Saunders, David Shadovitz, Robert Everland III) > > > > > action="CREATE"> > > > > But something's screwy > > > > Here's the first error: > > Content: Error trying to create object specified in the tag. COM error > > 0x80070005. Access is denied. > > > > Maybe I should add server so here's the next error: > > Error trying to create object specified in the tag. COM error >0x80040154. > > Class not registered > > > > Then I go in to the oleviewer and find the class of the object and try >to > > create it using > > > ACTION="CREATE" > > CLASS={000209FF---C000-0046} > > NAME="WordApp" > > TYPE="COM" > > CONTEXT="Remote" > > SERVER="(serverIP)"> > > Content: Error trying to create object specified in the tag. COM error > > 0x80070005. Access is denied. > > > > or if I add the computer name using //servername > > Content: Error trying to create object specified in the tag. COM error > > 0x800706BA. The RPC server is unavailable. Depending on how I write the > > server name > > (but I think I put the servername wrong that's all) > > > > I think it's the service permissions but then I check and CF logs in as >an > > administrator. > > > > Any thoughts? > > > > > > ~| Archives: http://www.houseoffusion.com/cf_lists/index.cfm?forumid=4 Subscription: http://www.houseoffusion.com/cf_lists/index.cfm?method=subscribe&forumid=4 FAQ: http://www.thenetprofits.co.uk/coldfusion/faq Get the mailserver that powers this list at http://www.coolfusion.com Unsubscribe: http://www.houseoffusion.com/cf_lists/unsubscribe.cfm?user=89.70.4
Re: Problems com class word.application
I am facing a similar problem, I think, in that I can't figure out what to use for the "class" attribute. In ASP I would just use the CLSID, but OLEView doesn't give anything for class name for the COM (ocx) that I'm trying to use. - Original Message - From: "Joshua O'Connor-Rose" <[EMAIL PROTECTED]> > Trying out a couple of Word2HTML tools > They finaly get a copy of Word2000 installed and I set up. > Word2HTML on the server (author Randy Mayes) > > This gives me: > The error occurred while processing an element with a general identifier of > (CFX_WORD2HTML), occupying document position (115:3) to (121:19) in the > template file D:\applications\CFusion\CustomTags\Word2HTML.cfm. > > (That would be in the custom tag itself) > > So I figure I'll debug the thing by creating objects myself. > Using word2HTML.cfm > (authors Greg Saunders, David Shadovitz, Robert Everland III) > > action="CREATE"> > > But something's screwy > > Here's the first error: > Content: Error trying to create object specified in the tag. COM error > 0x80070005. Access is denied. > > Maybe I should add server so here's the next error: > Error trying to create object specified in the tag. COM error 0x80040154. > Class not registered > > Then I go in to the oleviewer and find the class of the object and try to > create it using > ACTION="CREATE" > CLASS={000209FF---C000-0046} > NAME="WordApp" > TYPE="COM" > CONTEXT="Remote" > SERVER="(serverIP)"> > Content: Error trying to create object specified in the tag. COM error > 0x80070005. Access is denied. > > or if I add the computer name using //servername > Content: Error trying to create object specified in the tag. COM error > 0x800706BA. The RPC server is unavailable. Depending on how I write the > server name > (but I think I put the servername wrong that's all) > > I think it's the service permissions but then I check and CF logs in as an > administrator. > > Any thoughts? ~| Archives: http://www.houseoffusion.com/cf_lists/index.cfm?forumid=4 Subscription: http://www.houseoffusion.com/cf_lists/index.cfm?method=subscribe&forumid=4 FAQ: http://www.thenetprofits.co.uk/coldfusion/faq This list and all House of Fusion resources hosted by CFHosting.com. The place for dependable ColdFusion Hosting. Unsubscribe: http://www.houseoffusion.com/cf_lists/unsubscribe.cfm?user=89.70.4
Problems com class word.application
Trying out a couple of Word2HTML tools They finaly get a copy of Word2000 installed and I set up. Word2HTML on the server (author Randy Mayes) This gives me: The error occurred while processing an element with a general identifier of (CFX_WORD2HTML), occupying document position (115:3) to (121:19) in the template file D:\applications\CFusion\CustomTags\Word2HTML.cfm. (That would be in the custom tag itself) So I figure I'll debug the thing by creating objects myself. Using word2HTML.cfm (authors Greg Saunders, David Shadovitz, Robert Everland III) But something's screwy Here's the first error: Content: Error trying to create object specified in the tag. COM error 0x80070005. Access is denied. Maybe I should add server so here's the next error: Error trying to create object specified in the tag. COM error 0x80040154. Class not registered Then I go in to the oleviewer and find the class of the object and try to create it using Content: Error trying to create object specified in the tag. COM error 0x80070005. Access is denied. or if I add the computer name using //servername Content: Error trying to create object specified in the tag. COM error 0x800706BA. The RPC server is unavailable. Depending on how I write the server name (but I think I put the servername wrong that's all) I think it's the service permissions but then I check and CF logs in as an administrator. Any thoughts? -From the desk of Joshua O'Connor-Rose (aka Whifflebat) -All is Good ~| Archives: http://www.houseoffusion.com/cf_lists/index.cfm?forumid=4 Subscription: http://www.houseoffusion.com/cf_lists/index.cfm?method=subscribe&forumid=4 FAQ: http://www.thenetprofits.co.uk/coldfusion/faq Get the mailserver that powers this list at http://www.coolfusion.com Unsubscribe: http://www.houseoffusion.com/cf_lists/unsubscribe.cfm?user=89.70.4