Every time I have had the orange alarm light on one of my WIC cards, AND I
was sure that all the cabling and everything on my end was OK, I found that
it was the carrier. I would have them do a thorough diagnostics and see if
they can latch on to your CSU, etc.
""Wilson, Christian"" wrote in message
[EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
> Hi all
>
> I have a 1602R with a WIC-1DSU-T1 card installed. I am trying to bring up
> the line, but the interface is down/down. The ISP swears that I have the
> correct linecode, frame type, and other settings. A debug serial
interface
> shows:
>
> QUICC_Serial1: Reset from x45623q21
>
> It keeps trying to restart and keeps getting reset with the above debug
> code. I have checked the cables. The lights on the WIC are CD
illuminated
> and ALARM illuminated. I searched the archives and found someone had the
> same problem back in april with the a 1603 and the same debug trace, but
no
> one replied. Please help! I have no where else to turn as I have no
> maintenance on this router. Thanks
Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=55235&t=55234
--
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]