Re: 911....Help Needed soft error Token Ring

2000-09-26 Thread Flem

You are trying to solve something that is not a real
problem . The message :

Last Ring Status 00:32:29 Soft Error (0x2000)

indicates that the last status was a soft error . 
Mostlikely because insertion/removal of a station in
the ring ( 1/2 hour ago ) . This is not a problem .

Are actually see a problem on the ring beside this
message ?

flem

--- Jim Barksdale [EMAIL PROTECTED]
wrote:
 Here is what I found and the site where I found it
 
 
* The Active Monitor removes circulating
 frames from the ring. As
 a
frame passes the Active Monitor, a special
 bit called a monitor
count bit is set. If the monitor count bit is
 set, the Active
Monitor assumes the original sender of the
 frame was unable to
remove the frame from the ring. The Active
 Monitor purges this
frame, and sends a Token Error Soft Error to
 the Ring Error
 Monitor.
 
 
 http://www.landfield.com/faqs/LANs/token-ring-faq/
 
 Jim
 
 Leon Bass wrote:
 
  I have been trying to track down a solution for
 this error, any
  suggestions are appreciated.
 
  I have changed cables.
  And in the process of scheduling to switch
 TokenRing cards.
  I have pasted the interface with the erroe as it
 appears.
 
  TokenRing0/0 is up, line protocol is up
Hardware is IBM, address is 1110.12ae.1212
 (bia 0180.69ae.1234)
Internet address is 192.99.29.1/24
MTU 4464 bytes, BW 16000 Kbit, DLY 630 usec,
   reliability 255/255, txload 1/255, rxload
 1/255
Encapsulation SNAP, loopback not set
Keepalive set (10 sec)
ARP type: SNAP, ARP Timeout 04:00:00
Ring speed: 16 Mbps
Duplex: half
Mode: Classic token ring station
Group Address: 0x, Functional Address:
 0x0800
Ethernet Transit OUI: 0x00
Last Ring Status 00:32:29 Soft Error (0x2000)
Last input 00:00:00, output 00:00:00, output
 hang never
Last clearing of "show interface" counters never
Queueing strategy: fifo
Output queue 0/40, 0 drops; input queue 0/75, 0
 drops
5 minute input rate 1 bits/sec, 11
 packets/sec
5 minute output rate 2000 bits/sec, 3
 packets/sec
   2968655 packets input, 416906220 bytes, 0 no
 buffer
   Received 0 broadcasts, 0 runts, 0 giants, 0
 throttles
   256 input errors, 2 CRC, 0 frame, 0 overrun,
 0 ignored, 0 abort
   --More--
 
 


__
Do You Yahoo!?
Send instant messages  get email alerts with Yahoo! Messenger.
http://im.yahoo.com/

**NOTE: New CCNA/CCDA List has been formed. For more information go to
http://www.groupstudy.com/list/Associates.html
_
UPDATED Posting Guidelines: http://www.groupstudy.com/list/guide.html
FAQ, list archives, and subscription info: http://www.groupstudy.com
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]



Re: 911....Help Needed soft error Token Ring

2000-09-26 Thread Leon Bass

THANKS GUYS!!

Flem wrote:

 You are trying to solve something that is not a real
 problem . The message :

 Last Ring Status 00:32:29 Soft Error (0x2000)

 indicates that the last status was a soft error .
 Mostlikely because insertion/removal of a station in
 the ring ( 1/2 hour ago ) . This is not a problem .

 Are actually see a problem on the ring beside this
 message ?

 flem

 --- Jim Barksdale [EMAIL PROTECTED]
 wrote:
  Here is what I found and the site where I found it
 
 
 * The Active Monitor removes circulating
  frames from the ring. As
  a
 frame passes the Active Monitor, a special
  bit called a monitor
 count bit is set. If the monitor count bit is
  set, the Active
 Monitor assumes the original sender of the
  frame was unable to
 remove the frame from the ring. The Active
  Monitor purges this
 frame, and sends a Token Error Soft Error to
  the Ring Error
  Monitor.
 
 
  http://www.landfield.com/faqs/LANs/token-ring-faq/
 
  Jim
 
  Leon Bass wrote:
 
   I have been trying to track down a solution for
  this error, any
   suggestions are appreciated.
  
   I have changed cables.
   And in the process of scheduling to switch
  TokenRing cards.
   I have pasted the interface with the erroe as it
  appears.
  
   TokenRing0/0 is up, line protocol is up
 Hardware is IBM, address is 1110.12ae.1212
  (bia 0180.69ae.1234)
 Internet address is 192.99.29.1/24
 MTU 4464 bytes, BW 16000 Kbit, DLY 630 usec,
reliability 255/255, txload 1/255, rxload
  1/255
 Encapsulation SNAP, loopback not set
 Keepalive set (10 sec)
 ARP type: SNAP, ARP Timeout 04:00:00
 Ring speed: 16 Mbps
 Duplex: half
 Mode: Classic token ring station
 Group Address: 0x, Functional Address:
  0x0800
 Ethernet Transit OUI: 0x00
 Last Ring Status 00:32:29 Soft Error (0x2000)
 Last input 00:00:00, output 00:00:00, output
  hang never
 Last clearing of "show interface" counters never
 Queueing strategy: fifo
 Output queue 0/40, 0 drops; input queue 0/75, 0
  drops
 5 minute input rate 1 bits/sec, 11
  packets/sec
 5 minute output rate 2000 bits/sec, 3
  packets/sec
2968655 packets input, 416906220 bytes, 0 no
  buffer
Received 0 broadcasts, 0 runts, 0 giants, 0
  throttles
256 input errors, 2 CRC, 0 frame, 0 overrun,
  0 ignored, 0 abort
--More--
  
 

 __
 Do You Yahoo!?
 Send instant messages  get email alerts with Yahoo! Messenger.
 http://im.yahoo.com/

 **NOTE: New CCNA/CCDA List has been formed. For more information go to
 http://www.groupstudy.com/list/Associates.html
 _
 UPDATED Posting Guidelines: http://www.groupstudy.com/list/guide.html
 FAQ, list archives, and subscription info: http://www.groupstudy.com
 Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

**NOTE: New CCNA/CCDA List has been formed. For more information go to
http://www.groupstudy.com/list/Associates.html
_
UPDATED Posting Guidelines: http://www.groupstudy.com/list/guide.html
FAQ, list archives, and subscription info: http://www.groupstudy.com
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]



Re: 911....Help Needed soft error Token Ring

2000-09-25 Thread Jim Barksdale


Here is what I found and the site where I found it

 * The Active Monitor removes circulating
frames from the ring. As a
 frame passes the Active Monitor,
a special bit called a monitor
 count bit is set. If the monitor
count bit is set, the Active
 Monitor assumes the original sender
of the frame was unable to
 remove the frame from the ring.
The Active Monitor purges this
 frame, and sends a Token Error
Soft Error to the Ring Error Monitor.

http://www.landfield.com/faqs/LANs/token-ring-faq/
Jim
Leon Bass wrote:
I have been trying to track down a solution for this
error, any suggestions are appreciated.
I have changed cables.
And in the process of scheduling to switch TokenRing cards.
I have pasted the interface with the erroe as it appears.
TokenRing0/0 is up, line protocol is up
 Hardware is IBM, address is 1110.12ae.1212 (bia 0180.69ae.1234)
 Internet address is 192.99.29.1/24
 MTU 4464 bytes, BW 16000 Kbit, DLY 630 usec,
 reliability 255/255, txload 1/255, rxload
1/255
 Encapsulation SNAP, loopback not set
 Keepalive set (10 sec)
 ARP type: SNAP, ARP Timeout 04:00:00
 Ring speed: 16 Mbps
 Duplex: half
 Mode: Classic token ring station
 Group Address: 0x, Functional Address: 0x0800
 Ethernet Transit OUI: 0x00
 Last Ring Status 00:32:29 Soft Error> (0x2000)
 Last input 00:00:00, output 00:00:00, output hang never
 Last clearing of "show interface" counters never
 Queueing strategy: fifo
 Output queue 0/40, 0 drops; input queue 0/75, 0 drops
 5 minute input rate 1 bits/sec, 11 packets/sec
 5 minute output rate 2000 bits/sec, 3 packets/sec
 2968655 packets input, 416906220 bytes, 0
no buffer
 Received 0 broadcasts, 0 runts, 0 giants,
0 throttles
 256 input errors, 2 CRC, 0 frame, 0 overrun,
0 ignored, 0 abort
--More--




911....Help Needed soft error Token Ring

2000-09-19 Thread Leon Bass


I have been trying to track down a solution for this error, any suggestions
are appreciated.
I have changed cables.
And in the process of scheduling to switch TokenRing cards.
I have pasted the interface with the erroe as it appears.
TokenRing0/0 is up, line protocol is up
 Hardware is IBM, address is 1110.12ae.1212 (bia 0180.69ae.1234)
 Internet address is 192.99.29.1/24
 MTU 4464 bytes, BW 16000 Kbit, DLY 630 usec,
 reliability 255/255, txload 1/255, rxload
1/255
 Encapsulation SNAP, loopback not set
 Keepalive set (10 sec)
 ARP type: SNAP, ARP Timeout 04:00:00
 Ring speed: 16 Mbps
 Duplex: half
 Mode: Classic token ring station
 Group Address: 0x, Functional Address: 0x0800
 Ethernet Transit OUI: 0x00
 Last Ring Status 00:32:29 Soft Error> (0x2000)
 Last input 00:00:00, output 00:00:00, output hang never
 Last clearing of "show interface" counters never
 Queueing strategy: fifo
 Output queue 0/40, 0 drops; input queue 0/75, 0 drops
 5 minute input rate 1 bits/sec, 11 packets/sec
 5 minute output rate 2000 bits/sec, 3 packets/sec
 2968655 packets input, 416906220 bytes, 0
no buffer
 Received 0 broadcasts, 0 runts, 0 giants,
0 throttles
 256 input errors, 2 CRC, 0 frame, 0 overrun,
0 ignored, 0 abort
--More--