RE: Issue with 6509 [7:71468]
Explanation This message indicates an underflow in the port ASIC transmit buffer. The first [dec] is the module number. The second [dec] is the ASIC port number. Action If the error is limited to a single module, replace the module. If the error occurs several times, contact your technical support representative Hope this helps ! :) -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] Sent: Thursday, June 26, 2003 9:07 PM To: [EMAIL PROTECTED] Subject: Issue with 6509 [7:71468] Having a problem with 12 ports on one of our 6509's.. They are unable to pass traffic, and I get the following errors on the console. 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #2: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #3: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #4: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #5: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #6: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #7: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #8: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #9: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #10: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #11: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #12: Does anyone know what this means? Thanks, Mario Puras SoluNet Technical Support Mailto: [EMAIL PROTECTED] Direct: (321) 309-1410 888.449.5766 (USA) / 888.SOLUNET (Canada) NOTICE - This message contains privileged and confidential information intended only for the use of the addressee named above. Any review, retransmission, dissemination, copying, disclosure or other use of, or taking of any action in reliance upon, this information by person or entities other than the intended recipient is prohibited. If you have received this message in error, please notify the sender by return email and delete this message. This message should not be copied or used for any purpose other than intended, nor should it be disclosed to any other person. Any views expressed in this message are those of the individual sender, except where the sender specifically states them to be the view of Investec Group, its subsidiaries or associates. The Investec Group is not liable for the security of information sent by e-mail at your request, nor for the proper and complete transmission of the information contained in the communication nor for any delay in its receipt. Please note that the recipient must scan this e-mail and any attached files for viruses and the like. The Investec Group accepts no liability of whatever nature for any loss, liability, damage or expense resulting directly or indirectly from the access of any files which are attached to this message. Message Posted at: http://www.groupstudy.com/form/read.php?f=7i=71685t=71468 -- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]
RE: Issue with 6509 [7:71468]
What trick? :-) (Remember the Quoting in Replies message that John sent out that stated, When responding to a post, PLEASE QUOTE WHAT YOU'RE REPLYING TO!) :-) Shawn K. -Original Message- From: David Vital [mailto:[EMAIL PROTECTED] Sent: Thursday, June 26, 2003 11:36 PM To: [EMAIL PROTECTED] Subject: Re: Issue with 6509 [7:71468] Hey that's a good trick to throw in the Bag. I havn't had this problem happen yet. the only problem I have had from the 6509's is a Belly up sup mod. Message Posted at: http://www.groupstudy.com/form/read.php?f=7i=71528t=71468 -- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]
RE: Issue with 6509 [7:71468]
Line card in slot 6 is bad, replace it..the error is related to a Hardware failure on the board... Larry Letterman Cisco Systems -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of [EMAIL PROTECTED] Sent: Thursday, June 26, 2003 12:07 PM To: [EMAIL PROTECTED] Subject: Issue with 6509 [7:71468] Having a problem with 12 ports on one of our 6509's.. They are unable to pass traffic, and I get the following errors on the console. 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #2: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #3: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #4: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #5: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #6: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #7: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #8: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #9: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #10: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #11: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #12: Does anyone know what this means? Thanks, Mario Puras SoluNet Technical Support Mailto: [EMAIL PROTECTED] Direct: (321) 309-1410 888.449.5766 (USA) / 888.SOLUNET (Canada) Message Posted at: http://www.groupstudy.com/form/read.php?f=7i=71474t=71468 -- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]
RE: Issue with 6509 [7:71468]
You have a BAD ASIC on your module. RMA baby! What kind of module is it? I have seen many issues with the 6348 blades as ASIC's failing. With the 6348 mod, ASIC's come in 12 port clusters per ASIC.. when the ASIC's fail to process, you get Coil errors.. You can either, move your connections to a different ASIC on the asme module, or blade, but your probably better off RMAing it in case of future problems.. HTH, [EMAIL PROTECTED] wrote: Having a problem with 12 ports on one of our 6509's.. They are unable to pass traffic, and I get the following errors on the console. 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #2: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #3: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #4: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #5: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #6: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #7: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #8: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #9: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #10: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #11: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #12: Does anyone know what this means? Thanks, Mario Puras SoluNet Technical Support Mailto: [EMAIL PROTECTED] Direct: (321) 309-1410 888.449.5766 (USA) / 888.SOLUNET (Canada) Message Posted at: http://www.groupstudy.com/form/read.php?f=7i=71473t=71468 -- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]
Re: Issue with 6509 [7:71468]
1. %SYS-3-SYS_LCPERR3:Module [dec]: Bus Asic #[dec] out of sync error This message indicates a multiple-synchronization problem between the bus ASIC and the port ASIC. The first [dec] is the module number. The second [dec] is the ASIC number. Recommended Action: Replace the module if the error occurs several times, or contact your technical support representative. Dave [EMAIL PROTECTED] wrote: Having a problem with 12 ports on one of our 6509's.. They are unable to pass traffic, and I get the following errors on the console. 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #2: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #3: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #4: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #5: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #6: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #7: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #8: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #9: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #10: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #11: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #12: Does anyone know what this means? Thanks, Mario Puras SoluNet Technical Support Mailto: [EMAIL PROTECTED] Direct: (321) 309-1410 888.449.5766 (USA) / 888.SOLUNET (Canada) -- David Madland CCIE# 2016 Sr. Network Engineer Qwest Communications 612-664-3367 Government can do something for the people only in proportion as it can do something to the people. -- Thomas Jefferson Message Posted at: http://www.groupstudy.com/form/read.php?f=7i=71480t=71468 -- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]
Re: Issue with 6509 [7:71468]
Mario, Found this through the Cisco Output Interpreter: %SYS-3-SYS_LCPERR3 (x0):Module [dec]: Coil Pb Tx Underflow Error - Port #dec] Explanation: This message indicates an underflow in the port ASIC transmit buffer. The first [dec] is the module number. The second [dec] is the ASIC port number. Recommended Action: If the error is limited to a single module, replace the module. If the error occurs several times, contact your technical support representative. Having a problem with 12 ports on one of our 6509's.. They are unable to pass traffic, and I get the following errors on the console. 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #2: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #3: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #4: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #5: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #6: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #7: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #8: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #9: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #10: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #11: 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #12: Does anyone know what this means? Thanks, Mario Puras SoluNet Technical Support Mailto: [EMAIL PROTECTED] Direct: (321) 309-1410 888.449.5766 (USA) / 888.SOLUNET (Canada) Message Posted at: http://www.groupstudy.com/form/read.php?f=7i=71476t=71468 -- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]
Re: Issue with 6509 [7:71468]
wrote in message... Having a problem with 12 ports on one of our 6509's.. They are unable to pass traffic, and I get the following errors on the console. 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow Error - Port #2: I'm surpised at all the poor responses to this posting. This is the Pinnacle COIL ASIC bug... very well-known on the Cat6k platform. It affects 12 ports at a time ... (on yours it is ports 1-12), because the Pinnacle ASIC services 12 ports grouped together. It only affects the WS-X6248-RJ-45 and WS-X6348-RJ-45 modules. The bug is not a hardware-only bug, there are actually two versions of the bug, one is hardware and the other is software. If you are running code CatOS 6.x, then it is more likely the software bug. In both cases, you should be able to power off and power on the module to make the error go away (no need to RMA). I have found this to be true about 36 out of the 40 times I've done this. Only in a few cases was it hardware-related. Reseating the module is the second mostly likely thing to fix the module. However, a soft reset does not seem to make the condition disappear. Open a Cisco case and then try the following: set module power down 6 set module power up 6 Also, you shouldn't rely on mailing-lists for this type of information, the Cisco TAC is the best place for Cisco bug resolution... -dre Message Posted at: http://www.groupstudy.com/form/read.php?f=7i=71486t=71468 -- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]