Re: [Elecraft] Fw: KPA 500 HV Problem.

2019-04-30 Thread Bob McGraw K4TAX
That 270 volts you refer to is the  "270 VDC" from the power supply.   
Check to see the covers are on tight and aligned correctly such that the 
safety interlock is engaged as it should be.   Make sure a wire is not 
holding the cover off and thus not seating correctly.


73

Bob, K4TAX


On 4/30/2019 2:52 PM, Mike Streeter via Elecraft wrote:
  


- Forwarded Message - From: Mike Streeter To: 
elecraft@mailman.qth.net Sent: ‎Tuesday‎, ‎April‎ ‎30‎, 
‎2019‎ ‎02‎:‎50‎:‎12‎ ‎PM‎ ‎CDTSubject: KPA 500 HV Problem.
  My KPA 500 has been running ok for several years on 120 Volts. Today I turned it off on 
the back , unplugged it and opened the top because I thought I might need to change the 
voltage tap. I did not need to change it. I replaced the top cover, plugged it in and 
turned it on at the back. All ok, but when I turned it on with the front panel button the 
HV reads .1 in standby. If I tap OPER it shows a hard fault and "270V error" 
.The Manual says this is a 270V supply failure and to recycle the mains power KPA 500 
after it is corrected. I tried recycling the power but still faults. I don't have any 
270V power from the mains, if I did it would be 240ish, not 270. The fuse block on the 
back is set to 115V.Any advice would be welcome.Mike, WM5DX.

__

Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html


__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Re: [Elecraft] Fw: KPA 500 HV Problem.

2019-04-30 Thread hawley, charles j jr
The pin diode bias supply is 270dc. That is what is failing. Has nothing to do 
with your mains.
Generally you should look at the last thing(s) you did before it failed. That 
is where you opened it up and did something. How did you determine that the HV 
was ok as is? Unplug anything...inadvertently...?
Take a look where you were inside. Something with the interlock micro switch?

Chuck Hawley
 c-haw...@illinois.edu

 Amateur Radio, KE9UW



From: elecraft-boun...@mailman.qth.net  on 
behalf of Mike Streeter via Elecraft 
Sent: Tuesday, April 30, 2019 2:52 PM
To: Elecraft Reflector
Subject: [Elecraft] Fw: KPA 500 HV Problem.



   - Forwarded Message - From: Mike Streeter To: 
elecraft@mailman.qth.net Sent: ‎Tuesday‎, ‎April‎ 
‎30‎, ‎2019‎ ‎02‎:‎50‎:‎12‎ ‎PM‎ ‎CDTSubject: KPA 500 HV Problem.
 My KPA 500 has been running ok for several years on 120 Volts. Today I turned 
it off on the back , unplugged it and opened the top because I thought I might 
need to change the voltage tap. I did not need to change it. I replaced the top 
cover, plugged it in and turned it on at the back. All ok, but when I turned it 
on with the front panel button the HV reads .1 in standby. If I tap OPER it 
shows a hard fault and "270V error" .The Manual says this is a 270V supply 
failure and to recycle the mains power KPA 500 after it is corrected. I tried 
recycling the power but still faults. I don't have any 270V power from the 
mains, if I did it would be 240ish, not 270. The fuse block on the back is set 
to 115V.Any advice would be welcome.Mike, WM5DX.

__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

[Elecraft] Fw: KPA 500 HV Problem.

2019-04-30 Thread Mike Streeter via Elecraft
 

   - Forwarded Message - From: Mike Streeter To: 
elecraft@mailman.qth.net Sent: ‎Tuesday‎, ‎April‎ 
‎30‎, ‎2019‎ ‎02‎:‎50‎:‎12‎ ‎PM‎ ‎CDTSubject: KPA 500 HV Problem.
 My KPA 500 has been running ok for several years on 120 Volts. Today I turned 
it off on the back , unplugged it and opened the top because I thought I might 
need to change the voltage tap. I did not need to change it. I replaced the top 
cover, plugged it in and turned it on at the back. All ok, but when I turned it 
on with the front panel button the HV reads .1 in standby. If I tap OPER it 
shows a hard fault and "270V error" .The Manual says this is a 270V supply 
failure and to recycle the mains power KPA 500 after it is corrected. I tried 
recycling the power but still faults. I don't have any 270V power from the 
mains, if I did it would be 240ish, not 270. The fuse block on the back is set 
to 115V.Any advice would be welcome.Mike, WM5DX.
   
__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net