Re: [Elecraft] K3 Firmware upload elapsed time

2012-12-03 Thread n4qs
No, that's not normal.  It should only take a few minutes.

Dave, N4QS
Sent via BlackBerry by ATT

-Original Message-
From: Nand Kishore vu2...@gmail.com
Sender: elecraft-boun...@mailman.qth.net
Date: Mon, 3 Dec 2012 18:51:44 
To: elecraftelecraft@mailman.qth.net
Subject: [Elecraft] K3 Firmware upload elapsed time

What should be the time taken to do an upload for a K3 with subrx.
In my case its about 70 minutes.Is this normal ?

Nandu
Vu2nks
K3 # 282
__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html


Re: [Elecraft] K3 Firmware upload elapsed time

2012-12-03 Thread Dave Lankshear
Check the bitrate between your computer and the K3.  Unless there are
problems, it should run at 38kbits/S.  That's when it takes just a few
minutes, but you may have yours set to a very slow speed.

 

HTH

 

73 Dave G3TJP

__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html


Re: [Elecraft] K3 Firmware upload elapsed time

2012-12-03 Thread Matt Zilmer
Try turning on Advanced Mode in the View menu.  If the link is causing
errors, they'll be annunciated on the Send MCU Firmware pane.  You
should see the progress bar marking a new block of code every few
seconds.

73,
matt W6NIA

On Mon, 03 Dec 2012 19:32:42 +0530, you wrote:

Handshake between K3 and Comp. via utility is auto set at 38.4K.
That,s what I have seen. I don't get a look in.

Nandu
__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html


Re: [Elecraft] K3 Firmware upload elapsed time

2012-12-03 Thread Dick Dievendorff
About five to eight minutes is normal. You may have many retries, indicating a 
less than ideal RS-232 connection. Use the view menu, verbose settings for 
explicit indications of each retry. Check that your cable hold down screws are 
snug. Try the troubleshooting steps in K3 Utility Help for USB to serial 
adapters if that is what you are using.  If the RS232 cabling path is complex 
(many connectors) try to simplify it.

Firmware load is done  at 38400 bps.

73 de Dick, K6KR


On Dec 3, 2012, at 5:21 AM, Nand Kishore vu2...@gmail.com wrote:

 What should be the time taken to do an upload for a K3 with subrx.
 In my case its about 70 minutes.Is this normal ?
 
 Nandu
 Vu2nks
 K3 # 282
 __
 Elecraft mailing list
 Home: http://mailman.qth.net/mailman/listinfo/elecraft
 Help: http://mailman.qth.net/mmfaq.htm
 Post: mailto:Elecraft@mailman.qth.net
 
 This list hosted by: http://www.qsl.net
 Please help support this email list: http://www.qsl.net/donate.html
__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html


Re: [Elecraft] K3 Firmware upload elapsed time

2012-12-03 Thread Nand Kishore
Hi Dick,
I have been battling with an ERR TXG problem. I am in touch with
support.Have changed LPA.
No improvement in out put power,cannot exceed 10w with KPA3 in line.About
0.6W with KPA3
bypassed.Various voltages taken with rf probe as advised reported back to
support.Was advised
to do ref cal again.
So,I did the full F/W down load,latest regular release with latest utility.
It has been taking a long
time to do F/W load lately,but always without any retries.
So,I thought of asking here if the time taken to load was a norm.If the F/W
is not done right,should
I not sort it out first before looking at H/W.

I have K3/100 # 282 + KRX3 + KDVR + P3.
Using Laptop with pcmcia dual serial port card.

73 de Nandu

On Mon, Dec 3, 2012 at 9:04 PM, Dick Dievendorff die...@comcast.net wrote:

 About five to eight minutes is normal. You may have many retries,
 indicating a less than ideal RS-232 connection. Use the view menu, verbose
 settings for explicit indications of each retry. Check that your cable hold
 down screws are snug. Try the troubleshooting steps in K3 Utility Help for
 USB to serial adapters if that is what you are using.  If the RS232 cabling
 path is complex (many connectors) try to simplify it.

 Firmware load is done  at 38400 bps.

 73 de Dick, K6KR


 On Dec 3, 2012, at 5:21 AM, Nand Kishore vu2...@gmail.com wrote:

  What should be the time taken to do an upload for a K3 with subrx.
  In my case its about 70 minutes.Is this normal ?
 
  Nandu
  Vu2nks
  K3 # 282


__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html


Re: [Elecraft] K3 Firmware upload elapsed time

2012-12-03 Thread Dick Dievendorff
Has that serial path worked more quickly in the past? Do you have alternatives 
available to try?  That load time is terrible v

Dick


On Dec 3, 2012, at 7:56 AM, Nand Kishore vu2...@gmail.com wrote:

 Hi Dick,
 I have been battling with an ERR TXG problem. I am in touch with support.Have 
 changed LPA.
 No improvement in out put power,cannot exceed 10w with KPA3 in line.About 
 0.6W with KPA3
 bypassed.Various voltages taken with rf probe as advised reported back to 
 support.Was advised
 to do ref cal again.
 So,I did the full F/W down load,latest regular release with latest utility. 
 It has been taking a long
 time to do F/W load lately,but always without any retries.
 So,I thought of asking here if the time taken to load was a norm.If the F/W 
 is not done right,should
 I not sort it out first before looking at H/W.
 
 I have K3/100 # 282 + KRX3 + KDVR + P3.
 Using Laptop with pcmcia dual serial port card.
 
 73 de Nandu 
 
 On Mon, Dec 3, 2012 at 9:04 PM, Dick Dievendorff die...@comcast.net wrote:
 About five to eight minutes is normal. You may have many retries, indicating 
 a less than ideal RS-232 connection. Use the view menu, verbose settings for 
 explicit indications of each retry. Check that your cable hold down screws 
 are snug. Try the troubleshooting steps in K3 Utility Help for USB to serial 
 adapters if that is what you are using.  If the RS232 cabling path is 
 complex (many connectors) try to simplify it.
 
 Firmware load is done  at 38400 bps.
 
 73 de Dick, K6KR
 
 
 On Dec 3, 2012, at 5:21 AM, Nand Kishore vu2...@gmail.com wrote:
 
  What should be the time taken to do an upload for a K3 with subrx.
  In my case its about 70 minutes.Is this normal ?
 
  Nandu
  Vu2nks
  K3 # 282
 
__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html


Re: [Elecraft] K3 Firmware upload elapsed time

2012-12-03 Thread Nand Kishore
Yes, the uploads have been faster before.Now I will try with regular usb to
serial cable which
I had kept aside as I wanted FSK. Now I will take the cable directly to K3
instead of via P3.
I have no other PC.
Will report back.
73 de Nandu

On Mon, Dec 3, 2012 at 9:41 PM, Dick Dievendorff die...@comcast.net wrote:

 Has that serial path worked more quickly in the past? Do you have
 alternatives available to try?  That load time is terrible v

 Dick


 On Dec 3, 2012, at 7:56 AM, Nand Kishore vu2...@gmail.com wrote:

 Hi Dick,
 I have been battling with an ERR TXG problem. I am in touch with
 support.Have changed LPA.
 No improvement in out put power,cannot exceed 10w with KPA3 in line.About
 0.6W with KPA3
 bypassed.Various voltages taken with rf probe as advised reported back to
 support.Was advised
 to do ref cal again.
 So,I did the full F/W down load,latest regular release with latest
 utility. It has been taking a long
 time to do F/W load lately,but always without any retries.
 So,I thought of asking here if the time taken to load was a norm.If the
 F/W is not done right,should
 I not sort it out first before looking at H/W.

 I have K3/100 # 282 + KRX3 + KDVR + P3.
 Using Laptop with pcmcia dual serial port card.

 73 de Nandu

 On Mon, Dec 3, 2012 at 9:04 PM, Dick Dievendorff die...@comcast.netwrote:

 About five to eight minutes is normal. You may have many retries,
 indicating a less than ideal RS-232 connection. Use the view menu, verbose
 settings for explicit indications of each retry. Check that your cable hold
 down screws are snug. Try the troubleshooting steps in K3 Utility Help for
 USB to serial adapters if that is what you are using.  If the RS232 cabling
 path is complex (many connectors) try to simplify it.

 Firmware load is done  at 38400 bps.

 73 de Dick, K6KR


 On Dec 3, 2012, at 5:21 AM, Nand Kishore vu2...@gmail.com wrote:

  What should be the time taken to do an upload for a K3 with subrx.
  In my case its about 70 minutes.Is this normal ?
 
  Nandu
  Vu2nks
  K3 # 282



__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html


Re: [Elecraft] K3 Firmware upload elapsed time

2012-12-03 Thread Cady, Fred
Make sure you have the latest version of the K3 Utility.

Fred Cady
fcady at ieee dot org 

 -Original Message-
 From: elecraft-boun...@mailman.qth.net [mailto:elecraft-
 boun...@mailman.qth.net] On Behalf Of Nand Kishore
 Sent: Monday, December 03, 2012 9:31 AM
 To: Dick Dievendorff
 Cc: elecraft
 Subject: Re: [Elecraft] K3 Firmware upload elapsed time
 
 Yes, the uploads have been faster before.Now I will try with regular
 usb to
 serial cable which
 I had kept aside as I wanted FSK. Now I will take the cable directly
to
 K3
 instead of via P3.
 I have no other PC.
 Will report back.
 73 de Nandu
 
 On Mon, Dec 3, 2012 at 9:41 PM, Dick Dievendorff die...@comcast.net
 wrote:
 
  Has that serial path worked more quickly in the past? Do you have
  alternatives available to try?  That load time is terrible v
 
  Dick
 
 
  On Dec 3, 2012, at 7:56 AM, Nand Kishore vu2...@gmail.com wrote:
 
  Hi Dick,
  I have been battling with an ERR TXG problem. I am in touch with
  support.Have changed LPA.
  No improvement in out put power,cannot exceed 10w with KPA3 in
 line.About
  0.6W with KPA3
  bypassed.Various voltages taken with rf probe as advised reported
 back to
  support.Was advised
  to do ref cal again.
  So,I did the full F/W down load,latest regular release with latest
  utility. It has been taking a long
  time to do F/W load lately,but always without any retries.
  So,I thought of asking here if the time taken to load was a norm.If
 the
  F/W is not done right,should
  I not sort it out first before looking at H/W.
 
  I have K3/100 # 282 + KRX3 + KDVR + P3.
  Using Laptop with pcmcia dual serial port card.
 
  73 de Nandu
 
  On Mon, Dec 3, 2012 at 9:04 PM, Dick Dievendorff
 die...@comcast.netwrote:
 
  About five to eight minutes is normal. You may have many retries,
  indicating a less than ideal RS-232 connection. Use the view menu,
 verbose
  settings for explicit indications of each retry. Check that your
 cable hold
  down screws are snug. Try the troubleshooting steps in K3 Utility
 Help for
  USB to serial adapters if that is what you are using.  If the RS232
 cabling
  path is complex (many connectors) try to simplify it.
 
  Firmware load is done  at 38400 bps.
 
  73 de Dick, K6KR
 
 
  On Dec 3, 2012, at 5:21 AM, Nand Kishore vu2...@gmail.com wrote:
 
   What should be the time taken to do an upload for a K3 with
subrx.
   In my case its about 70 minutes.Is this normal ?
  
   Nandu
   Vu2nks
   K3 # 282
 
 
 
 __
 Elecraft mailing list
 Home: http://mailman.qth.net/mailman/listinfo/elecraft
 Help: http://mailman.qth.net/mmfaq.htm
 Post: mailto:Elecraft@mailman.qth.net
 
 This list hosted by: http://www.qsl.net
 Please help support this email list: http://www.qsl.net/donate.html
__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html


Re: [Elecraft] K3 Firmware upload elapsed time

2012-12-03 Thread Nand Kishore
K3 Utility # 1.12.10.10 in use.
Tried upload agn with P3 bypassed.Regular usb to serial cable originally
procured from Elecraft used.No upload failure.No retries.

MCU load time 2.25 m
FPF  load time 2.20 m
DSP1 load time  34.30m


On Mon, Dec 3, 2012 at 10:06 PM, Cady, Fred fc...@ece.montana.edu wrote:

 Make sure you have the latest version of the K3 Utility.

 Fred Cady
 fcady at ieee dot org

  -Original Message-
  From: elecraft-boun...@mailman.qth.net [mailto:elecraft-
  boun...@mailman.qth.net] On Behalf Of Nand Kishore
  Sent: Monday, December 03, 2012 9:31 AM
  To: Dick Dievendorff
  Cc: elecraft
  Subject: Re: [Elecraft] K3 Firmware upload elapsed time
 
  Yes, the uploads have been faster before.Now I will try with regular
  usb to
  serial cable which
  I had kept aside as I wanted FSK. Now I will take the cable directly
 to
  K3
  instead of via P3.
  I have no other PC.
  Will report back.
  73 de Nandu
 
  On Mon, Dec 3, 2012 at 9:41 PM, Dick Dievendorff die...@comcast.net
  wrote:
 
   Has that serial path worked more quickly in the past? Do you have
   alternatives available to try?  That load time is terrible v
  
   Dick
  
 

__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html