Re: [gmx-users] Membrane Equilibration

2013-06-11 Thread Dr. Vitaly Chaban
what happens to your energy before the observed crash? does the crash
happen at the same time-step each time?


Dr. Vitaly Chaban


On Tue, Jun 11, 2013 at 5:22 PM, Neha nshafi...@wesleyan.edu wrote:

 Hi everybody,

 I am trying to simulate a lipid bilayer and wanted to use Parrinello Rahman
 coupling. However, I read that Parinello-Rahman is not great for
 equilibration so I thought I would do a small run using the Berendsen
 barostat to decrease the chances of large oscillations. I then used the
 .gro
 file obtained from that run to start a new run using Parrinello-Rahman. I
 am
 not sure if that's the correct way to go about doing what I want to do.

 My Parrinello run also terminated a little while in, with the error that 2
 of my atoms have moved further apart than the cut-off distance. A part of
 my
 mdp file is pasted below and I was wondering if anyone had any suggestions
 as to stop that from happening. My time step is 0.02 ps and I thought
 increasing tau-p might work. I am using the compressibility from the map
 file on the Martini website and am worried that might be too large. Any
 help
 will be super useful! Let me know if you need any more information.


 ; OPTIONS FOR WEAK COUPLING ALGORITHMS =
 ; Temperature coupling   =
 tcoupl   = nose-hoover
 ; Groups to couple separately =
 tc-grps  = DPPC W
 ; Time constant (ps) and reference temperature (K) =
 tau_t= 1.0 1.0
 ref_t= 320 320
 nsttcouple   = 1
 ; Pressure coupling  =
 Pcoupl   = Parrinello-Rahman
 Pcoupltype   = semiisotropic
 ; Time constant (ps), compressibility (1/bar) and reference P (bar) =
 tau_p= 5.0  5.0
 compressibility  = 3e-4 3e-4
 ref_p= 0.0  0.0
 nstpcouple   = 5

 ; GENERATE VELOCITIES FOR STARTUP RUN =
 gen_vel  = yes
 gen_temp = 105
 gen_seed = 473529



 --
 View this message in context:
 http://gromacs.5086.x6.nabble.com/Membrane-Equilibration-tp5009038.html
 Sent from the GROMACS Users Forum mailing list archive at Nabble.com.
 --
 gmx-users mailing listgmx-users@gromacs.org
 http://lists.gromacs.org/mailman/listinfo/gmx-users
 * Please search the archive at
 http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
 * Please don't post (un)subscribe requests to the list. Use the
 www interface or send it to gmx-users-requ...@gromacs.org.
 * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

-- 
gmx-users mailing listgmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
* Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to gmx-users-requ...@gromacs.org.
* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists


Re: [gmx-users] Membrane Equilibration

2013-06-11 Thread HANNIBAL LECTER
ref_p= 0.0  0.0 ??

Are you sure about this??


On Tue, Jun 11, 2013 at 12:08 PM, Dr. Vitaly Chaban vvcha...@gmail.comwrote:

 what happens to your energy before the observed crash? does the crash
 happen at the same time-step each time?


 Dr. Vitaly Chaban


 On Tue, Jun 11, 2013 at 5:22 PM, Neha nshafi...@wesleyan.edu wrote:

  Hi everybody,
 
  I am trying to simulate a lipid bilayer and wanted to use Parrinello
 Rahman
  coupling. However, I read that Parinello-Rahman is not great for
  equilibration so I thought I would do a small run using the Berendsen
  barostat to decrease the chances of large oscillations. I then used the
  .gro
  file obtained from that run to start a new run using Parrinello-Rahman. I
  am
  not sure if that's the correct way to go about doing what I want to do.
 
  My Parrinello run also terminated a little while in, with the error that
 2
  of my atoms have moved further apart than the cut-off distance. A part of
  my
  mdp file is pasted below and I was wondering if anyone had any
 suggestions
  as to stop that from happening. My time step is 0.02 ps and I thought
  increasing tau-p might work. I am using the compressibility from the map
  file on the Martini website and am worried that might be too large. Any
  help
  will be super useful! Let me know if you need any more information.
 
 
  ; OPTIONS FOR WEAK COUPLING ALGORITHMS =
  ; Temperature coupling   =
  tcoupl   = nose-hoover
  ; Groups to couple separately =
  tc-grps  = DPPC W
  ; Time constant (ps) and reference temperature (K) =
  tau_t= 1.0 1.0
  ref_t= 320 320
  nsttcouple   = 1
  ; Pressure coupling  =
  Pcoupl   = Parrinello-Rahman
  Pcoupltype   = semiisotropic
  ; Time constant (ps), compressibility (1/bar) and reference P (bar) =
  tau_p= 5.0  5.0
  compressibility  = 3e-4 3e-4
  ref_p= 0.0  0.0
  nstpcouple   = 5
 
  ; GENERATE VELOCITIES FOR STARTUP RUN =
  gen_vel  = yes
  gen_temp = 105
  gen_seed = 473529
 
 
 
  --
  View this message in context:
  http://gromacs.5086.x6.nabble.com/Membrane-Equilibration-tp5009038.html
  Sent from the GROMACS Users Forum mailing list archive at Nabble.com.
  --
  gmx-users mailing listgmx-users@gromacs.org
  http://lists.gromacs.org/mailman/listinfo/gmx-users
  * Please search the archive at
  http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
  * Please don't post (un)subscribe requests to the list. Use the
  www interface or send it to gmx-users-requ...@gromacs.org.
  * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists
 
 --
 gmx-users mailing listgmx-users@gromacs.org
 http://lists.gromacs.org/mailman/listinfo/gmx-users
 * Please search the archive at
 http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
 * Please don't post (un)subscribe requests to the list. Use the
 www interface or send it to gmx-users-requ...@gromacs.org.
 * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

-- 
gmx-users mailing listgmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
* Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to gmx-users-requ...@gromacs.org.
* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists


Re: [gmx-users] Membrane Equilibration

2013-06-11 Thread Justin Lemkul



On 6/11/13 1:13 PM, HANNIBAL LECTER wrote:

ref_p= 0.0  0.0 ??

Are you sure about this??



That's a likely culprit.  See below for another.



On Tue, Jun 11, 2013 at 12:08 PM, Dr. Vitaly Chaban vvcha...@gmail.comwrote:


what happens to your energy before the observed crash? does the crash
happen at the same time-step each time?


Dr. Vitaly Chaban


On Tue, Jun 11, 2013 at 5:22 PM, Neha nshafi...@wesleyan.edu wrote:


Hi everybody,

I am trying to simulate a lipid bilayer and wanted to use Parrinello

Rahman

coupling. However, I read that Parinello-Rahman is not great for
equilibration so I thought I would do a small run using the Berendsen
barostat to decrease the chances of large oscillations. I then used the
.gro
file obtained from that run to start a new run using Parrinello-Rahman. I
am
not sure if that's the correct way to go about doing what I want to do.

My Parrinello run also terminated a little while in, with the error that

2

of my atoms have moved further apart than the cut-off distance. A part of
my
mdp file is pasted below and I was wondering if anyone had any

suggestions

as to stop that from happening. My time step is 0.02 ps and I thought
increasing tau-p might work. I am using the compressibility from the map
file on the Martini website and am worried that might be too large. Any
help
will be super useful! Let me know if you need any more information.


; OPTIONS FOR WEAK COUPLING ALGORITHMS =
; Temperature coupling   =
tcoupl   = nose-hoover
; Groups to couple separately =
tc-grps  = DPPC W
; Time constant (ps) and reference temperature (K) =
tau_t= 1.0 1.0
ref_t= 320 320
nsttcouple   = 1
; Pressure coupling  =
Pcoupl   = Parrinello-Rahman
Pcoupltype   = semiisotropic
; Time constant (ps), compressibility (1/bar) and reference P (bar) =
tau_p= 5.0  5.0
compressibility  = 3e-4 3e-4
ref_p= 0.0  0.0
nstpcouple   = 5

; GENERATE VELOCITIES FOR STARTUP RUN =
gen_vel  = yes
gen_temp = 105


Here is another issue.  You're re-generating velocities (destroying the previous 
equilibration) with a barostat that doesn't usually play nice under such 
circumstances, and you're generating velocities for a temperature well below the 
target defined in ref_t.  That can cause the thermostat to go haywire, which 
then has negative effects on the pressure (which comes from kinetic energy and 
the virial), which can lead to collapse.


-Justin

--


Justin A. Lemkul, Ph.D.
Research Scientist
Department of Biochemistry
Virginia Tech
Blacksburg, VA
jalemkul[at]vt.edu | (540) 231-9080
http://www.bevanlab.biochem.vt.edu/Pages/Personal/justin


--
gmx-users mailing listgmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
* Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to gmx-users-requ...@gromacs.org.

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists