3590 Tape error when vol=ser not specified
OLD SYSTEM (OS/390 1.3) I'm changing from 3480 tape drives to 3590. Everything is working, but when I allocate a "private" scratch tape an IOE error always hits the console. It's not a hi-lited msg and doesn't seem to affect anything, but I can't figure out why I always get this error. If I specify "vol=ser=" for the output tape, the error doesn't occur. Below is the jcl and error. //GREGTAPE JOB ,'G.L.CASERTA',MSGCLASS=X //STEP1 EXEC PGM=IEBGENER //SYSINDD DUMMY //SYSPRINT DD SYSOUT=* //SYSUT1 DD DSN=GLC.JUNK132,DISP=SHR //SYSUT2 DD DSN=GLC.JUNK3590,DISP=(,CATLG),UNIT=3590-1,VOL=SER=003601 //* *IEF233A M 0100,PRIVAT,SL,GREGTAPE,COPY3590 IOS000I 0100,0B,IOE,9F,0600,,**,,*MASTER* 701 804010C021122141 009FFF00 0092 40042300B39A1313 CONFIGURATION ERROR This document has been scanned by Special Metals Corporation for viruses and inappropriate content. It contains information intended only for the individual named. If you are not the named addressee you should not disseminate, distribute or copy this e-mail. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and delete this e-mail from your system. E-mail transmission cannot be guaranteed to be secure or error-free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or contain viruses. The sender therefore does not accept liability for any errors or omissions in the contents of this message, which arise as a result of e-mail transmission. If verification is required please request a hard-copy version. Special Metals Corporation, 3200 Riverside Drive, Huntington, WV 25705, USA, www.specialmetals.com -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: 3590 Tape error when vol=ser not specified
No autoloader. Here is the results from the d u,,,100 ( the drives are offline right now) D U,,,0100 IEE457I 16.17.24 UNIT STATUS 161 UNIT TYPE STATUSVOLSER VOLSTATE 0100 359S F-NRD/REMOV 0101 359S F-NRD/REMOV 0102 359S F-NRD/REMOV 0103 359S F-NRD/REMOV -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of R.S. Sent: Thursday, February 24, 2011 4:07 PM To: IBM-MAIN@bama.ua.edu Subject: Re: 3590 Tape error when vol=ser not specified W dniu 2011-02-24 21:46, Greg Caserta pisze: > OLD SYSTEM (OS/390 1.3) > I'm changing from 3480 tape drives to 3590. Everything is working, but when > I allocate a "private" scratch tape an IOE error always hits the console. > It's not a hi-lited msg and doesn't seem to affect anything, but I can't > figure out why I always get this error. If I specify "vol=ser=" for the > output tape, the error doesn't occur. Below is the jcl and error. > > //GREGTAPE JOB ,'G.L.CASERTA',MSGCLASS=X > //STEP1 EXEC PGM=IEBGENER > //SYSINDD DUMMY > //SYSPRINT DD SYSOUT=* > //SYSUT1 DD DSN=GLC.JUNK132,DISP=SHR > //SYSUT2 DD DSN=GLC.JUNK3590,DISP=(,CATLG),UNIT=3590-1,VOL=SER=003601 > //* > > *IEF233A M 0100,PRIVAT,SL,GREGTAPE,COPY3590 > IOS000I 0100,0B,IOE,9F,0600,,**,,*MASTER* 701 >804010C021122141 009FFF00 0092 40042300B39A1313 >CONFIGURATION ERROR Wild guess: You don't have autoloader in your 3590. (if yes) Don't worry about it, just ignore. BTW: provide us D U,,,0100output if you want further analysis. HTH -- Radoslaw Skorupka Lodz, Poland -- BRE Bank SA ul. Senatorska 18 00-950 Warszawa www.brebank.pl Sd Rejonowy dla m. st. Warszawy XII Wydzia Gospodarczy Krajowego Rejestru Sdowego, nr rejestru przedsibiorców KRS 025237 NIP: 526-021-50-88 Wedug stanu na dzie 16.07.2010 r. kapita zakadowy BRE Banku SA (w caoci wpacony) wynosi 168.248.328 zotych. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html This document has been scanned by Special Metals Corporation for viruses and inappropriate content. It contains information intended only for the individual named. If you are not the named addressee you should not disseminate, distribute or copy this e-mail. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and delete this e-mail from your system. E-mail transmission cannot be guaranteed to be secure or error-free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or contain viruses. The sender therefore does not accept liability for any errors or omissions in the contents of this message, which arise as a result of e-mail transmission. If verification is required please request a hard-copy version. Special Metals Corporation, 3200 Riverside Drive, Huntington, WV 25705, USA, www.specialmetals.com -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: 3590 Tape error when vol=ser not specified
THANK YOU SO MUCH -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of R.S. Sent: Thursday, February 24, 2011 4:33 PM To: IBM-MAIN@bama.ua.edu Subject: Re: 3590 Tape error when vol=ser not specified W dniu 2011-02-24 22:19, Greg Caserta pisze: > No autoloader. Here is the results from the d u,,,100 ( the drives are > offline right now) > D U,,,0100 > IEE457I 16.17.24 UNIT STATUS 161 > UNIT TYPE STATUSVOLSER VOLSTATE > 0100 359S F-NRD/REMOV > 0101 359S F-NRD/REMOV > 0102 359S F-NRD/REMOV > 0103 359S F-NRD/REMOV See IEE457I explanation: xxxS where xxx represents the first three digits of device type (for example, '348' for a 3480 or '349' for a 3490) and 'S' means the device has a cartridge stack loader. So, your OS/390 *thinks* that your 3590 does have autoloader. Lack of autoloader casues surprise and message. However AFAIR it doesn't hurt. You can simply ignore the messages. AFAIR they appear only for non-specific volume requests. -- Radoslaw Skorupka Lodz, Poland -- BRE Bank SA ul. Senatorska 18 00-950 Warszawa www.brebank.pl Sd Rejonowy dla m. st. Warszawy XII Wydzia Gospodarczy Krajowego Rejestru Sdowego, nr rejestru przedsibiorców KRS 025237 NIP: 526-021-50-88 Wedug stanu na dzie 16.07.2010 r. kapita zakadowy BRE Banku SA (w caoci wpacony) wynosi 168.248.328 zotych. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html This document has been scanned by Special Metals Corporation for viruses and inappropriate content. It contains information intended only for the individual named. If you are not the named addressee you should not disseminate, distribute or copy this e-mail. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and delete this e-mail from your system. E-mail transmission cannot be guaranteed to be secure or error-free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or contain viruses. The sender therefore does not accept liability for any errors or omissions in the contents of this message, which arise as a result of e-mail transmission. If verification is required please request a hard-copy version. Special Metals Corporation, 3200 Riverside Drive, Huntington, WV 25705, USA, www.specialmetals.com -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
FIXED ! 3590 Tape error when vol=ser not specified
THANKS ALL ! -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of Robert A. Rosenberg Sent: Friday, February 25, 2011 2:36 PM To: IBM-MAIN@bama.ua.edu Subject: Re: 3590 Tape error when vol=ser not specified At 22:33 +0100 on 02/24/2011, R.S. wrote about Re: 3590 Tape error when vol=ser not specified: >So, your OS/390 *thinks* that your 3590 does have autoloader. >Lack of autoloader casues surprise and message. However AFAIR it doesn't >hurt. You can simply ignore the messages. Or has your Systems Programmer do a new Sysgen to remove the Autoloader from the Device Definitions. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html This document has been scanned by Special Metals Corporation for viruses and inappropriate content. It contains information intended only for the individual named. If you are not the named addressee you should not disseminate, distribute or copy this e-mail. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and delete this e-mail from your system. E-mail transmission cannot be guaranteed to be secure or error-free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or contain viruses. The sender therefore does not accept liability for any errors or omissions in the contents of this message, which arise as a result of e-mail transmission. If verification is required please request a hard-copy version. Special Metals Corporation, 3200 Riverside Drive, Huntington, WV 25705, USA, www.specialmetals.com -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: 3590 Tape error when vol=ser not specified
EXCELLENT HELP THANKS -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of R.S. Sent: Friday, February 25, 2011 4:05 PM To: IBM-MAIN@bama.ua.edu Subject: Re: 3590 Tape error when vol=ser not specified W dniu 2011-02-25 20:35, Robert A. Rosenberg pisze: > At 22:33 +0100 on 02/24/2011, R.S. wrote about Re: 3590 Tape error when > vol=ser not specified: > >> So, your OS/390 *thinks* that your 3590 does have autoloader. >> Lack of autoloader casues surprise and message. However AFAIR it doesn't >> hurt. You can simply ignore the messages. > > Or has your Systems Programmer do a new Sysgen to remove the Autoloader > from the Device Definitions. System programmer? I doubt. IMHO there is no option *in the system* (HCD, IODF, DFSMS) which corresponds autoloader. The only place to configure it is tape controller - J70, A60, or A05. And this is job for CE, not sysprog. -- Radoslaw Skorupka Lodz, Poland -- BRE Bank SA ul. Senatorska 18 00-950 Warszawa www.brebank.pl Sd Rejonowy dla m. st. Warszawy XII Wydzia Gospodarczy Krajowego Rejestru Sdowego, nr rejestru przedsibiorców KRS 025237 NIP: 526-021-50-88 Wedug stanu na dzie 16.07.2010 r. kapita zakadowy BRE Banku SA (w caoci wpacony) wynosi 168.248.328 zotych. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html This document has been scanned by Special Metals Corporation for viruses and inappropriate content. It contains information intended only for the individual named. If you are not the named addressee you should not disseminate, distribute or copy this e-mail. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and delete this e-mail from your system. E-mail transmission cannot be guaranteed to be secure or error-free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or contain viruses. The sender therefore does not accept liability for any errors or omissions in the contents of this message, which arise as a result of e-mail transmission. If verification is required please request a hard-copy version. Special Metals Corporation, 3200 Riverside Drive, Huntington, WV 25705, USA, www.specialmetals.com -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
ADMIN failure using DUMP command in pgm ADRDSSU
RUNNING CA'S TOP SECRET 5.0 I'm trying to dump all my disk to tape for a DR test and I believe I need to use the ADMIN keyword. Error when using the ADMIN keyword on the Dump command of pgm ADRDSSU. PAGE 0001 5695-DF175 DFSMSDSS V1R3.0 DATA SET SERVICES 2011.066 DUMP FULL INDD(INVOL) OUTDD(OUTVOL) ADMIN ALLDATA(*) TOL(IOER) ALLEXCP ADR101I (R/I)-RI01 (01), TASKID 001 HAS BEEN ASSIGNED TO COMMAND 'DUMP ' ADR109I (R/I)-RI01 (01), 2011.066 15:43:57 INITIAL SCAN OF USER CONTROL S ADR707E (R/I)-RI03 (06), NOT AUTHORIZED TO USE ADMINISTRATOR KEYWORD ADR017E (001)-CLTSK(01), 2011.066 15:43:57 TASK NOT SCHEDULED DUE TO ERRO ADR012I (SCH)-DSSU (01), 2011.066 15:43:57 DFSMSDSS PROCESSING COMPLETE. Below is my Top Secret accesses but I can't figure out what else I need to use the ADMIN keyword. READY TSS LIST(GLC) DATA(ALL,PASSWORD) ACCESSORID = GLC NAME = CASERTA, GREG TYPE = CENTRAL SIZE = 512 BYTES FACILITY = *ALL* CREATED= 01/29/07 LAST MOD = 03/07/11 14:21 PROFILES = SYSTECP SYSPRGP SALARYP SMCTECH ATTRIBUTES = CONSOLE BYPASSING = NODSNCHK,NOVOLCHK,NORESCHK,NOLCFCHK,NOSUBCHK,NOVMDCHK LAST USED = 03/07/11 15:51 CPU(INCO) FAC(BATCH ) COUNT(25965) XA OTRAN = CEMT OWNER(SYSCOMP ACCESS = ALL INSTDATA = TECHNICAL SUPPORT --- SEGMENT CICS OPIDENT= GLC --- ADMINISTRATION AUTHORITIES RESOURCE = *ALL* ACCESS = ALL ACID = *ALL* FACILITIES = *ALL* LIST DATA = *ALL*,PROFILES,PASSWORD,SESSKEY MISC1 = *ALL* MISC2 = *ALL* MISC8 = *ALL* MISC9 = *ALL* PASSWORD = TSS0300I LIST FUNCTION SUCCESSFUL READY END This document has been scanned by Special Metals Corporation for viruses and inappropriate content. It contains information intended only for the individual named. If you are not the named addressee you should not disseminate, distribute or copy this e-mail. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and delete this e-mail from your system. E-mail transmission cannot be guaranteed to be secure or error-free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or contain viruses. The sender therefore does not accept liability for any errors or omissions in the contents of this message, which arise as a result of e-mail transmission. If verification is required please request a hard-copy version. Special Metals Corporation, 3200 Riverside Drive, Huntington, WV 25705, USA, www.specialmetals.com -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
DFHSM V2.6 - Autodump how to stack disk vols on tape
DFHSM (autodump - 1 disk vol to 1 tape ?) I'm running DFHSM v2.6 on OS/390 1.3 (very old, I realize) Just put in a used Shark 2105 along with 3590 tape drives (20GB capacity). It used to take multiple tapes to dump a disk vol. Now I can dump all 76 disk vols onto 2 tapes if I manually do dfdss full dumps. When I run dfhsm's autodump, it dumps 1 disk vol to 1 tape, then the next disk vol to another tape, etc. etc. How can I change dfhsm to continue dumping disk vols until the tape is full, then call for another tape? This document has been scanned by Special Metals Corporation for viruses and inappropriate content. It contains information intended only for the individual named. If you are not the named addressee you should not disseminate, distribute or copy this e-mail. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and delete this e-mail from your system. E-mail transmission cannot be guaranteed to be secure or error-free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or contain viruses. The sender therefore does not accept liability for any errors or omissions in the contents of this message, which arise as a result of e-mail transmission. If verification is required please request a hard-copy version. Special Metals Corporation, 3200 Riverside Drive, Huntington, WV 25705, USA, www.specialmetals.com -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: DFHSM V2.6 - Autodump how to stack disk vols on tape
I don't see the DUMPCLASS(STACK) option in my v2.6 under os/390 1.3 I wonder if it will work? This sure looks like what I need. -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of O'Brien, David W. (NIH/CIT) [C] Sent: Wednesday, June 08, 2011 2:50 PM To: IBM-MAIN@bama.ua.edu Subject: Re: DFHSM V2.6 - Autodump how to stack disk vols on tape I think this is what you're looking for. 2.13.2.17 DUMPCLASS(STACK): Specifying the Maximum Number of Dump Copies that Are Stacked for this Dump Class (c) Copyright IBM Corp. 1984, 2009 Topic lines 1 to 16 of 47 Explanation: STACK is an optional subparameter of DUMPCLASS that specifies how many dump copies DFSMShsm should place on a dump volume that is assigned to this dump class during one invocation of automatic dump or BACKVOL dump. DUMPCLASS(STACK(nn)): For nn, substitute a value from 1 to 99. Given typical values of compression and the capacity of tape cartridges such as 3590, STACK values should be in the range of 10 to 12. All stacking to a given tape is done while that tape is mounted. DFSMShsm selects empty dump volumes as targets for auto or command dump. Each dump copy is written in its own file, with a unique data set name. As dump generations are rolled off when new dumps are created, a dump volume may contain a combination of valid and not valid dump copies. -Original Message----- From: Greg Caserta [mailto:gcase...@specialmetals.com] Sent: Wednesday, June 08, 2011 2:35 PM To: IBM-MAIN@bama.ua.edu Subject: DFHSM V2.6 - Autodump how to stack disk vols on tape DFHSM (autodump - 1 disk vol to 1 tape ?) I'm running DFHSM v2.6 on OS/390 1.3 (very old, I realize) Just put in a used Shark 2105 along with 3590 tape drives (20GB capacity). It used to take multiple tapes to dump a disk vol. Now I can dump all 76 disk vols onto 2 tapes if I manually do dfdss full dumps. When I run dfhsm's autodump, it dumps 1 disk vol to 1 tape, then the next disk vol to another tape, etc. etc. How can I change dfhsm to continue dumping disk vols until the tape is full, then call for another tape? This document has been scanned by Special Metals Corporation for viruses and inappropriate content. It contains information intended only for the individual named. If you are not the named addressee you should not disseminate, distribute or copy this e-mail. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and delete this e-mail from your system. E-mail transmission cannot be guaranteed to be secure or error-free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or contain viruses. The sender therefore does not accept liability for any errors or omissions in the contents of this message, which arise as a result of e-mail transmission. If verification is required please request a hard-copy version. Special Metals Corporation, 3200 Riverside Drive, Huntington, WV 25705, USA, www.specialmetals.com -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html This document has been scanned by Special Metals Corporation for viruses and inappropriate content. It contains information intended only for the individual named. If you are not the named addressee you should not disseminate, distribute or copy this e-mail. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and delete this e-mail from your system. E-mail transmission cannot be guaranteed to be secure or error-free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or contain viruses. The sender therefore does not accept liability for any errors or omissions in the contents of this message, which arise as a result of e-mail transmission. If verification is required please request a hard-copy version. Special Metals Corporation, 3200 Riverside Drive, Huntington, WV 25705, US
3490 MSG: LIBRARY INTERFACE IS OFFLINE
I am installing a 3490-c2a controller with 2-drives but cannot get past the "library interface is offline" error. Does the auto-loader have to be connected to this controller? RUNNING OS/390 1.3 HERE IS THE IOCP DEFINITION ( LIBRARY USE IS SET TO "NO" ) There is no "autoloader" attached. CNTLUNIT CUNUMBR=0400,PATH=(09),UNITADD=((00,016)), UNIT=3490-C2A IODEVICE ADDRESS=(400,002),CUNUMBR=(0400),STADET=Y,UNIT=3490 When I power off the unit, I get this failed message that tells me the unit/model. Notice 003490/C2A is correct. IOS581E LINK FAILED REPORTING CHPID=09 806 INCIDENT UNIT TM=002003/116 SER=IBM02-044312 IF=0009 IC=03 ATTACHED UNIT TM=003490/C2A SER=IBM77-040040 IF=0080 Channel came online fine CF CHP(09),ONLINE IEE712I CONFIG PROCESSING COMPLETE Channel path came online fine VARY PATH(0400-0401,09),ONLINE IEE302I PATH(0400,09) ONLINE IEE302I PATH(0401,09) ONLINE Devices won't come online VARY 400-401,ONLINE IEE103I UNIT 0400 NOT BROUGHT ONLINE 819 IEE763I NAME= IECTDSR2 CODE= 0008 IEA437I TAPE LIBRARY DEVICE(0400), LIBRARY INTERFACE IS OFFLINE IEE764I END OF IEE103IRELATED MESSAGES IEE103I UNIT 0401 NOT BROUGHT ONLINE 820 IEE763I NAME= IECTDSR2 CODE= 0008 IEA437I TAPE LIBRARY DEVICE(0401), LIBRARY INTERFACE IS OFFLINE IEE764I END OF IEE103IRELATED MESSAGES Displayed the unit status D U,,,0400,2,L=MASTER-Z VARY RANGE DISPLAY IEE457I 09.55.29 UNIT STATUS 822 UNIT TYPE STATUSVOLSER VOLSTATE 0400 349L OFFLINE /REMOV 0401 349L OFFLINE /REMOV This document has been scanned by Special Metals Corporation for viruses and inappropriate content. It contains information intended only for the individual named. If you are not the named addressee you should not disseminate, distribute or copy this e-mail. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and delete this e-mail from your system. E-mail transmission cannot be guaranteed to be secure or error-free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or contain viruses. The sender therefore does not accept liability for any errors or omissions in the contents of this message, which arise as a result of e-mail transmission. If verification is required please request a hard-copy version. Special Metals Corporation, 3200 Riverside Drive, Huntington, WV 25705, USA, www.specialmetals.com -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: 3490 MSG: LIBRARY INTERFACE IS OFFLINE
The control unit is a 3490-C22 but the autoloader has been removed. When I power it off it says it is a 3490-C2A. I gen'd it as a C2A and a C22 but I get the same message. I do have HCD also. -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of Field, Alan C. Sent: Thursday, July 28, 2011 10:58 AM To: IBM-MAIN@bama.ua.edu Subject: Re: 3490 MSG: LIBRARY INTERFACE IS OFFLINE Greg, What about the software definitions? The D U with 349L says the devices are part of a LIBRARY which I don't think you want. OS/390 1.3? I don't think you have HCD at that version :(. What's the OUTPUT from the IOGEN say? Alan -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of Greg Caserta Sent: Thursday, July 28, 2011 09:27 To: IBM-MAIN@bama.ua.edu Subject: 3490 MSG: LIBRARY INTERFACE IS OFFLINE I am installing a 3490-c2a controller with 2-drives but cannot get past the "library interface is offline" error. Does the auto-loader have to be connected to this controller? RUNNING OS/390 1.3 HERE IS THE IOCP DEFINITION ( LIBRARY USE IS SET TO "NO" ) There is no "autoloader" attached. CNTLUNIT CUNUMBR=0400,PATH=(09),UNITADD=((00,016)), UNIT=3490-C2A IODEVICE ADDRESS=(400,002),CUNUMBR=(0400),STADET=Y,UNIT=3490 When I power off the unit, I get this failed message that tells me the unit/model. Notice 003490/C2A is correct. IOS581E LINK FAILED REPORTING CHPID=09 806 INCIDENT UNIT TM=002003/116 SER=IBM02-044312 IF=0009 IC=03 ATTACHED UNIT TM=003490/C2A SER=IBM77-040040 IF=0080 Channel came online fine CF CHP(09),ONLINE IEE712I CONFIG PROCESSING COMPLETE Channel path came online fine VARY PATH(0400-0401,09),ONLINE IEE302I PATH(0400,09) ONLINE IEE302I PATH(0401,09) ONLINE Devices won't come online VARY 400-401,ONLINE IEE103I UNIT 0400 NOT BROUGHT ONLINE 819 IEE763I NAME= IECTDSR2 CODE= 0008 IEA437I TAPE LIBRARY DEVICE(0400), LIBRARY INTERFACE IS OFFLINE IEE764I END OF IEE103IRELATED MESSAGES IEE103I UNIT 0401 NOT BROUGHT ONLINE 820 IEE763I NAME= IECTDSR2 CODE= 0008 IEA437I TAPE LIBRARY DEVICE(0401), LIBRARY INTERFACE IS OFFLINE IEE764I END OF IEE103IRELATED MESSAGES Displayed the unit status D U,,,0400,2,L=MASTER-Z VARY RANGE DISPLAY IEE457I 09.55.29 UNIT STATUS 822 UNIT TYPE STATUSVOLSER VOLSTATE 0400 349L OFFLINE /REMOV 0401 349L OFFLINE /REMOV This document has been scanned by Special Metals Corporation for viruses and inappropriate content. It contains information intended only for the individual named. If you are not the named addressee you should not disseminate, distribute or copy this e-mail. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and delete this e-mail from your system. E-mail transmission cannot be guaranteed to be secure or error-free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or contain viruses. The sender therefore does not accept liability for any errors or omissions in the contents of this message, which arise as a result of e-mail transmission. If verification is required please request a hard-copy version. Special Metals Corporation, 3200 Riverside Drive, Huntington, WV 25705, USA, www.specialmetals.com -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html This document has been scanned by Special Metals Corporation for viruses and inappropriate content. It contains information intended only for the individual named. If you are not the named addressee you should not disseminate, distribute or copy this e-mail. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and delete this e-mail from your system. E-mail transmission cannot be guaranteed to be secure or error-free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or contain viruses. The sender therefore does not accept liability for any errors or omissions in the contents of this message, which arise as a result of e-mail transmission. If verification is required please request a hard-copy version. Special Metals Corporation, 3200 Riverside Drive, Huntington, WV 25705, USA, www.specialmetals.com -- For IBM-MAIN
Re: 3490 MSG: LIBRARY INTERFACE IS OFFLINE
Here are my software definitions: 0400,23490 OFFLINE=NO,DYNAMIC=YES,LOCANY=NO, LIBRARY=NO,AUTOSWITCH=NO -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of Field, Alan C. Sent: Friday, July 29, 2011 9:38 AM To: IBM-MAIN@bama.ua.edu Subject: Re: 3490 MSG: LIBRARY INTERFACE IS OFFLINE What do you software definitions look like: here's mine from the HCD report for similar devices: 0580,43490 OFFLINE=YES,DYNAMIC=YES,LOCANY=YES, LIBRARY=NO,AUTOSWITCH=NO,MTL=NO,SHARABLE,COMPACT Note the LIBRARY=NO. -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of Greg Caserta Sent: Friday, July 29, 2011 07:02 To: IBM-MAIN@bama.ua.edu Subject: Re: 3490 MSG: LIBRARY INTERFACE IS OFFLINE The control unit is a 3490-C22 but the autoloader has been removed. When I power it off it says it is a 3490-C2A. I gen'd it as a C2A and a C22 but I get the same message. I do have HCD also. -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of Field, Alan C. Sent: Thursday, July 28, 2011 10:58 AM To: IBM-MAIN@bama.ua.edu Subject: Re: 3490 MSG: LIBRARY INTERFACE IS OFFLINE Greg, What about the software definitions? The D U with 349L says the devices are part of a LIBRARY which I don't think you want. OS/390 1.3? I don't think you have HCD at that version :(. What's the OUTPUT from the IOGEN say? Alan -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of Greg Caserta Sent: Thursday, July 28, 2011 09:27 To: IBM-MAIN@bama.ua.edu Subject: 3490 MSG: LIBRARY INTERFACE IS OFFLINE I am installing a 3490-c2a controller with 2-drives but cannot get past the "library interface is offline" error. Does the auto-loader have to be connected to this controller? RUNNING OS/390 1.3 HERE IS THE IOCP DEFINITION ( LIBRARY USE IS SET TO "NO" ) There is no "autoloader" attached. CNTLUNIT CUNUMBR=0400,PATH=(09),UNITADD=((00,016)), UNIT=3490-C2A IODEVICE ADDRESS=(400,002),CUNUMBR=(0400),STADET=Y,UNIT=3490 When I power off the unit, I get this failed message that tells me the unit/model. Notice 003490/C2A is correct. IOS581E LINK FAILED REPORTING CHPID=09 806 INCIDENT UNIT TM=002003/116 SER=IBM02-044312 IF=0009 IC=03 ATTACHED UNIT TM=003490/C2A SER=IBM77-040040 IF=0080 Channel came online fine CF CHP(09),ONLINE IEE712I CONFIG PROCESSING COMPLETE Channel path came online fine VARY PATH(0400-0401,09),ONLINE IEE302I PATH(0400,09) ONLINE IEE302I PATH(0401,09) ONLINE Devices won't come online VARY 400-401,ONLINE IEE103I UNIT 0400 NOT BROUGHT ONLINE 819 IEE763I NAME= IECTDSR2 CODE= 0008 IEA437I TAPE LIBRARY DEVICE(0400), LIBRARY INTERFACE IS OFFLINE IEE764I END OF IEE103IRELATED MESSAGES IEE103I UNIT 0401 NOT BROUGHT ONLINE 820 IEE763I NAME= IECTDSR2 CODE= 0008 IEA437I TAPE LIBRARY DEVICE(0401), LIBRARY INTERFACE IS OFFLINE IEE764I END OF IEE103IRELATED MESSAGES Displayed the unit status D U,,,0400,2,L=MASTER-Z VARY RANGE DISPLAY IEE457I 09.55.29 UNIT STATUS 822 UNIT TYPE STATUSVOLSER VOLSTATE 0400 349L OFFLINE /REMOV 0401 349L OFFLINE /REMOV This document has been scanned by Special Metals Corporation for viruses and inappropriate content. It contains information intended only for the individual named. If you are not the named addressee you should not disseminate, distribute or copy this e-mail. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and delete this e-mail from your system. E-mail transmission cannot be guaranteed to be secure or error-free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or contain viruses. The sender therefore does not accept liability for any errors or omissions in the contents of this message, which arise as a result of e-mail transmission. If verification is required please request a hard-copy version. Special Metals Corporation, 3200 Riverside Drive, Huntington, WV 25705, USA, www.specialmetals.com -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html This document has been scanned by Special Metals Corporation for viruses and inapprop
Re: 3490 MSG: LIBRARY INTERFACE IS OFFLINE
THANK YOU VERY MUCH. -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of Minoru Massaki Sent: Sunday, July 31, 2011 9:59 AM To: IBM-MAIN@bama.ua.edu Subject: Re: 3490 MSG: LIBRARY INTERFACE IS OFFLINE As far as I know, 3490-C2A is for 3494 Tape Library. (3490-C22 is for stand-alone.) So, 3490-C2A has interface to 3494 Library Manger (I think that the interface is RS-232C or LAN). So if you use 3490-C2A as stand-alone device, you have to remove the library interface feature(?). If my memory is correct, it is impossible. Please ask 3490-C2A hardware specialist. Minoru Massaki 2011/7/28 Greg Caserta : > I am installing a 3490-c2a controller with 2-drives but cannot get past the > "library interface is offline" error. > Does the auto-loader have to be connected to this controller? > > RUNNING OS/390 1.3 > HERE IS THE IOCP DEFINITION ( LIBRARY USE IS SET TO "NO" ) There is no > "autoloader" attached. > CNTLUNIT CUNUMBR=0400,PATH=(09),UNITADD=((00,016)), > UNIT=3490-C2A > IODEVICE ADDRESS=(400,002),CUNUMBR=(0400),STADET=Y,UNIT=3490 > > > When I power off the unit, I get this failed message that tells me the > unit/model. Notice 003490/C2A is correct. > IOS581E LINK FAILED REPORTING CHPID=09 806 >INCIDENT UNIT TM=002003/116 SER=IBM02-044312 IF=0009 IC=03 >ATTACHED UNIT TM=003490/C2A SER=IBM77-040040 IF=0080 > > Channel came online fine > CF CHP(09),ONLINE > IEE712I CONFIG PROCESSING COMPLETE > > Channel path came online fine > VARY PATH(0400-0401,09),ONLINE > IEE302I PATH(0400,09) ONLINE > IEE302I PATH(0401,09) ONLINE > > Devices won't come online > VARY 400-401,ONLINE > IEE103I UNIT 0400 NOT BROUGHT ONLINE 819 > IEE763I NAME= IECTDSR2 CODE= 0008 > IEA437I TAPE LIBRARY DEVICE(0400), LIBRARY INTERFACE IS OFFLINE > IEE764I END OF IEE103IRELATED MESSAGES > IEE103I UNIT 0401 NOT BROUGHT ONLINE 820 > IEE763I NAME= IECTDSR2 CODE= 0008 > IEA437I TAPE LIBRARY DEVICE(0401), LIBRARY INTERFACE IS OFFLINE > IEE764I END OF IEE103IRELATED MESSAGES > > Displayed the unit status > D U,,,0400,2,L=MASTER-Z VARY RANGE DISPLAY > IEE457I 09.55.29 UNIT STATUS 822 > UNIT TYPE STATUSVOLSER VOLSTATE > 0400 349L OFFLINE /REMOV > 0401 349L OFFLINE /REMOV > > > > This document has been scanned by Special Metals Corporation for viruses and > inappropriate content. It contains information intended only for the > individual named. If you are not the named addressee you should not > disseminate, distribute or copy this e-mail. Please notify the sender > immediately by e-mail if you have received this e-mail by mistake and delete > this e-mail from your system. E-mail transmission cannot be guaranteed to be > secure or error-free as information could be intercepted, corrupted, lost, > destroyed, arrive late or incomplete, or contain viruses. The sender > therefore does not accept liability for any errors or omissions in the > contents of this message, which arise as a result of e-mail transmission. If > verification is required please request a hard-copy version. Special Metals > Corporation, 3200 Riverside Drive, Huntington, WV 25705, USA, > www.specialmetals.com > > > -- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO > Search the archives at http://bama.ua.edu/archives/ibm-main.html > -- 全先 実 - Minoru Massaki (M*M) E-mail: mmass...@gmail.com -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html This document has been scanned by Special Metals Corporation for viruses and inappropriate content. It contains information intended only for the individual named. If you are not the named addressee you should not disseminate, distribute or copy this e-mail. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and delete this e-mail from your system. E-mail transmission cannot be guaranteed to be secure or error-free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or contain viruses. The sender therefore does not accept liability for any errors or omissions in the contents of this message, which arise as a result of e-mail transmission. If verification is required please request a hard-copy version. Special Metals Corporation, 3200 Riverside D
Re: 3490 MSG: LIBRARY INTERFACE IS OFFLINE (CLOSED ITEM)
Thanks again. You have been a great help. -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of Minoru Massaki Sent: Monday, August 01, 2011 10:48 AM To: IBM-MAIN@bama.ua.edu Subject: Re: 3490 MSG: LIBRARY INTERFACE IS OFFLINE According to 3490-C2A Sales Manual below: http://ebookbrowse.com/ibm-3490-c2a-sales-manual-doc-d110099512 It said following; The C2A is specifically designed for use in the 3494 Tape Library Dataserver and cannot be used outside of the tape library. Library Interface is RS-422, is not RS-232C. Sorry Minoru Massaki 2011年8月1日20:41 Greg Caserta : > THANK YOU VERY MUCH. > > -Original Message- > From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf > Of Minoru Massaki > Sent: Sunday, July 31, 2011 9:59 AM > To: IBM-MAIN@bama.ua.edu > Subject: Re: 3490 MSG: LIBRARY INTERFACE IS OFFLINE > > As far as I know, 3490-C2A is for 3494 Tape Library. > (3490-C22 is for stand-alone.) > So, 3490-C2A has interface to 3494 Library Manger (I think that the > interface is RS-232C or LAN). > So if you use 3490-C2A as stand-alone device, you have to remove the > library interface feature(?). If my memory is correct, it is > impossible. > Please ask 3490-C2A hardware specialist. > > Minoru Massaki > > 2011/7/28 Greg Caserta : >> I am installing a 3490-c2a controller with 2-drives but cannot get past the >> "library interface is offline" error. >> Does the auto-loader have to be connected to this controller? >> >> RUNNING OS/390 1.3 >> HERE IS THE IOCP DEFINITION ( LIBRARY USE IS SET TO "NO" ) There is no >> "autoloader" attached. >> CNTLUNIT CUNUMBR=0400,PATH=(09),UNITADD=((00,016)), >> UNIT=3490-C2A >> IODEVICE ADDRESS=(400,002),CUNUMBR=(0400),STADET=Y,UNIT=3490 >> >> >> When I power off the unit, I get this failed message that tells me the >> unit/model. Notice 003490/C2A is correct. >> IOS581E LINK FAILED REPORTING CHPID=09 806 >>INCIDENT UNIT TM=002003/116 SER=IBM02-044312 IF=0009 IC=03 >>ATTACHED UNIT TM=003490/C2A SER=IBM77-040040 IF=0080 >> >> Channel came online fine >> CF CHP(09),ONLINE >> IEE712I CONFIG PROCESSING COMPLETE >> >> Channel path came online fine >> VARY PATH(0400-0401,09),ONLINE >> IEE302I PATH(0400,09) ONLINE >> IEE302I PATH(0401,09) ONLINE >> >> Devices won't come online >> VARY 400-401,ONLINE >> IEE103I UNIT 0400 NOT BROUGHT ONLINE 819 >> IEE763I NAME= IECTDSR2 CODE= 0008 >> IEA437I TAPE LIBRARY DEVICE(0400), LIBRARY INTERFACE IS OFFLINE >> IEE764I END OF IEE103IRELATED MESSAGES >> IEE103I UNIT 0401 NOT BROUGHT ONLINE 820 >> IEE763I NAME= IECTDSR2 CODE= 0008 >> IEA437I TAPE LIBRARY DEVICE(0401), LIBRARY INTERFACE IS OFFLINE >> IEE764I END OF IEE103IRELATED MESSAGES >> >> Displayed the unit status >> D U,,,0400,2,L=MASTER-Z VARY RANGE DISPLAY >> IEE457I 09.55.29 UNIT STATUS 822 >> UNIT TYPE STATUSVOLSER VOLSTATE >> 0400 349L OFFLINE /REMOV >> 0401 349L OFFLINE /REMOV >> >> >> >> This document has been scanned by Special Metals Corporation for viruses and >> inappropriate content. It contains information intended only for the >> individual named. If you are not the named addressee you should not >> disseminate, distribute or copy this e-mail. Please notify the sender >> immediately by e-mail if you have received this e-mail by mistake and delete >> this e-mail from your system. E-mail transmission cannot be guaranteed to be >> secure or error-free as information could be intercepted, corrupted, lost, >> destroyed, arrive late or incomplete, or contain viruses. The sender >> therefore does not accept liability for any errors or omissions in the >> contents of this message, which arise as a result of e-mail transmission. If >> verification is required please request a hard-copy version. Special Metals >> Corporation, 3200 Riverside Drive, Huntington, WV 25705, USA, >> www.specialmetals.com >> >> >> -- >> For IBM-MAIN subscribe / signoff / archive access instructions, >> send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO >> Search the archives at http://bama.ua.edu/archives/ibm-main.html >> > > > > -- > > 全先 実 - Minoru Massaki (M*M) > E-mail: mmass...@gmail.com > > -- > For
3490 TAPE DRIVE SAYS 349L ???
Why 349L ? Running os/390 1.3 ( a bit old ) Configured iodef for 3490 tape but device says 349L. MVS COMMAND: D U,,,400,1 SHOWS THE DEVICE TYPE AS (349L) IOCP DEFINITION: CNTLUNIT CUNUMBR=0400,PATH=(09),UNITADD=((00,016)),UNIT=3490-C22 IODEVICE ADDRESS=(400,002),CUNUMBR=(0400),STADET=Y,UNIT=3490 This document has been scanned by Special Metals Corporation for viruses and inappropriate content. It contains information intended only for the individual named. If you are not the named addressee you should not disseminate, distribute or copy this e-mail. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and delete this e-mail from your system. E-mail transmission cannot be guaranteed to be secure or error-free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or contain viruses. The sender therefore does not accept liability for any errors or omissions in the contents of this message, which arise as a result of e-mail transmission. If verification is required please request a hard-copy version. Special Metals Corporation, 3200 Riverside Drive, Huntington, WV 25705, USA, www.specialmetals.com -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
THANKS ! RE: 3490 TAPE DRIVE SAYS 349L ???
Thanks everyone for your response. Sounds like I need to talk with the hardware folks and get the controller configured properly. Why 349L ? Running os/390 1.3 ( a bit old ) Configured iodef for 3490 tape but device says 349L. MVS COMMAND: D U,,,400,1 SHOWS THE DEVICE TYPE AS (349L) IOCP DEFINITION: CNTLUNIT CUNUMBR=0400,PATH=(09),UNITADD=((00,016)),UNIT=3490-C22 IODEVICE ADDRESS=(400,002),CUNUMBR=(0400),STADET=Y,UNIT=3490 This document has been scanned by Special Metals Corporation for viruses and inappropriate content. It contains information intended only for the individual named. If you are not the named addressee you should not disseminate, distribute or copy this e-mail. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and delete this e-mail from your system. E-mail transmission cannot be guaranteed to be secure or error-free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or contain viruses. The sender therefore does not accept liability for any errors or omissions in the contents of this message, which arise as a result of e-mail transmission. If verification is required please request a hard-copy version. Special Metals Corporation, 3200 Riverside Drive, Huntington, WV 25705, USA, www.specialmetals.com -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Logmode Entry not active?
I created a logmode table called "GREGTAB" and one of the macros is called "GC3270M4". The table is in vtamlib. When I try to logon to vtam using a cics application with the logmode: LOGON APPLID(CIC4) LOGMODE (GC3270M4) I get this message: APPLICATION INACTIVE TRY LATER -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html