Re: EDC4052

2011-05-16 Thread Bob Shannon
EDC4052W Module name &1 chosen for generated IMPORT control statements.

 Explanation:  The prelinker has assigned the default name TEMPNAME to the  
 module in the Definition Side-Deck.

 Programmer Response:  Include a NAME control statement in the prelinker
 input or specify the output object module of the prelinker to be a PDS 
 member so that the prelinker will use that as the module name in generated 
 IMPORT control statements. 

Bob Shannon
 

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html


EDC4052

2011-05-15 Thread Michael Klaeschen
Hello,

today I tried linking a successfully compiled C++ program but got message 
EDC4052 from cataloged procedure SYS1.PROCLIB(CBCL) in PLKED.SYSPRINT 
DD. Searching IBM Bookmanager for this message did not show even one 
result. Searching google gave a hint to PQ68700. But when following this link 
to IBM, I got "Error Document not found". Also IBM's "Technical help database 
for system z" did not show results, neither for EDC4052 nor for PQ68700.

The message text is 
WARNING EDC4052: Module name TEMPNAME chosen for generated IMPORT 
control statements.

z/OS is V1 R12, 
Prelinker is 5694A01 V1 R12 M0

Do you have an explanation of this message?

Thank you, kind regards
Michael

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html