Re: help needed with CICS/TS 3.2 abending U1800
McKown, John wrote: >Why does it always wait until I post a request for help? 'Ambush Abend?' ;-D It lie somewhere waiting to bite you on your when you expect the least... ;-D About your problem, sorry, I don't have any solution or suggestion. Good luck! Groete / Greetings Elardus Engelbrecht -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: help needed with CICS/TS 3.2 abending U1800
> -Original Message- > From: IBM Mainframe Discussion List > [mailto:ibm-m...@bama.ua.edu] On Behalf Of Patrick Lyon > Sent: Monday, August 09, 2010 7:28 AM > To: IBM-MAIN@bama.ua.edu > Subject: Re: help needed with CICS/TS 3.2 abending U1800 > > John - do you have both STGRCVY and STGPROT set to Yes? > > Looks like GSSP042 is being a bad boy and trying to overwrite > storage. You > might try to disable that program or transaction that is > associated with that > program. Yes to both. We found the problem. Sort of. We use BMC's Data Accelerator to compress files. The file being read in this case was a copy of a compressed file. Our copy program, FAVER, does not use VSAM LRM and so bypasses Data Accelerator during the dump. When restored, the file data is still compressed. The file in question did not show up in the Data Accelerator list of managed datasets. And has not in the reports for the last 5 days. But __somehow__ it does show up now! I am at loss since everybody disclaims making any changes in the interim. This really sucks. -- John McKown Systems Engineer IV IT Administrative Services Group HealthMarkets(r) 9151 Boulevard 26 * N. Richland Hills * TX 76010 (817) 255-3225 phone * (817)-961-6183 cell john.mck...@healthmarkets.com * www.HealthMarkets.com Confidentiality Notice: This e-mail message may contain confidential or proprietary information. If you are not the intended recipient, please contact the sender by reply e-mail and destroy all copies of the original message. HealthMarkets(r) is the brand name for products underwritten and issued by the insurance subsidiaries of HealthMarkets, Inc. -The Chesapeake Life Insurance Company(r), Mid-West National Life Insurance Company of TennesseeSM and The MEGA Life and Health Insurance Company.SM -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: help needed with CICS/TS 3.2 abending U1800
On Mon, 9 Aug 2010 07:33:51 -0500, McKown, John wrote: >Well, the damn thing has abended twice. We got everybody involved and I posted my "help" message. I just brought up the region and it is running fine now. We can't get it to fail again. Why does it always wait until I post a request for help? > It's just like when you want your job to finish type "DA" in SDSF. Do you have TMON for CICS or Omegamon to go back and see what transactions were executing at that time and had the abends? I would also see if you can find any change records through your change control to see what programs were promoted over the weekend, if any. You still have the SVC dumps you can go through as well. Good luck. I have a feeling this is not over. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: help needed with CICS/TS 3.2 abending U1800
Well, the damn thing has abended twice. We got everybody involved and I posted my "help" message. I just brought up the region and it is running fine now. We can't get it to fail again. Why does it always wait until I post a request for help? John McKown Systems Engineer IV IT Administrative Services Group HealthMarkets(r) 9151 Boulevard 26 * N. Richland Hills * TX 76010 (817) 255-3225 phone * (817)-961-6183 cell john.mck...@healthmarkets.com * www.HealthMarkets.com Confidentiality Notice: This e-mail message may contain confidential or proprietary information. If you are not the intended recipient, please contact the sender by reply e-mail and destroy all copies of the original message. HealthMarkets(r) is the brand name for products underwritten and issued by the insurance subsidiaries of HealthMarkets, Inc. -The Chesapeake Life Insurance Company(r), Mid-West National Life Insurance Company of TennesseeSM and The MEGA Life and Health Insurance Company.SM From: CICS List [mailto:cic...@listserv.uga.edu] On Behalf Of Earl Haigh Sent: Monday, August 09, 2010 7:30 AM To: cic...@listserv.uga.edu Subject: Re: help needed with CICS/TS 3.2 abending U1800 Do you have plt startup programs ? --- On Mon, 8/9/10, McKown, John wrote: From: McKown, John Subject: help needed with CICS/TS 3.2 abending U1800 To: cic...@listserv.uga.edu Date: Monday, August 9, 2010, 12:12 PM I'm going crazy and don't understand nor know how to debug this abend.. One of our CICS regions is abending shortly after coming up. The other region is not. Some of the messages that I'm seeing are just not of any use to me: +DFHSR0622 P3CH An attempt to overwrite the ECDSA has caused the abend which follows +DFHSR0001 P3CH An abend (code 0C4/AKEA) has occurred at offset X'' in program GSSP042. +DFHDU0205 P3CH A SYSTEM DUMP FOR DUMPCODE: SR0001 , WAS SUPPRESSED BY THE DUMP TABLE OPTION FOR THIS DUMPCODE +DFHSM0102 P3CH A storage violation (code X'030B') has been detected by module DFHSMGF. +DFHDU0201 P3CH ABOUT TO TAKE SDUMP. DUMPCODE: SM0102 , DUMPID: 1/0002 +DFHDU0202 P3CH SDUMPX COMPLETE. SDUMPX RETURN CODE X'00' IEA794I SVC DUMP HAS CAPTURED: 249 DUMPID=011 REQUESTED BY JOB (PCICS3 ) DUMP TITLE=CICS DUMP: SYSTEM=P3CH CODE=SM0102 ID=1/0002 +IEW2218S 0428 CANNOT MERGE ADDITIONAL MODULES WHEN INTENT IS ACCESS. IEF196I IGD104I SYSDUMP.LIH1.D100809.T113008.S00011.PCICS3 RETAINED, IEF196I DDNAME=SYS00015 IEA611I COMPLETE DUMP ON SYSDUMP.LIH1.D100809.T113008.S00011.PCICS3 270 DUMPID=011 REQUESTED BY JOB (PCICS3 ) FOR ASID (0086) INCIDENT TOKEN: LIH1 LIH1 08/09/2010 11:30:08 +DFHDU0201 P3CH ABOUT TO TAKE SDUMP. DUMPCODE: SM0102 , DUMPID: 1/0005 +DFHDU0202 P3CH SDUMPX COMPLETE. SDUMPX RETURN CODE X'00' IEA794I SVC DUMP HAS CAPTURED: 272 DUMPID=012 REQUESTED BY JOB (PCICS3 ) DUMP TITLE=CICS DUMP: SYSTEM=P3CH CODE=SM0102 ID=1/0005 +DFHSR0001 P3CH An abend (code 0C4/AKEA) has occurred at offset X'' in program GSSBRG1. == I'm really concerned with: +IEW2218S 0428 CANNOT MERGE ADDITIONAL MODULES WHEN INTENT IS ACCESS. == The two regions use the same DFHRPL concatenation. -- John McKown Systems Engineer IV IT Administrative Services Group HealthMarkets(r) 9151 Boulevard 26 * N. Richland Hills * TX 76010 (817) 255-3225 phone * (817)-961-6183 cell john.mck...@healthmarkets.com<http://us.mc653.mail.yahoo.com/mc/compose?to=john.mck...@healthmarkets.com> * www.HealthMarkets.com Confidentiality Notice: This e-mail message may contain confidential or proprietary information. If you are not the intended recipient, please contact the sender by reply e-mail and destroy all copies of the original message. HealthMarkets(r) is the brand name for products underwritten and issued by the insurance subsidiaries of HealthMarkets, Inc. -The Chesapeake Life Insurance Company(r), Mid-West National Life Insurance Company of TennesseeSM and The MEGA Life and Health Insurance Company.SM -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: help needed with CICS/TS 3.2 abending U1800
John - do you have both STGRCVY and STGPROT set to Yes? Looks like GSSP042 is being a bad boy and trying to overwrite storage. You might try to disable that program or transaction that is associated with that program. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html