SMF and LOGSTREAM Datasets

2011-09-28 Thread Henke, George
SMF data can now be sent to LOGSTREAM datasets thus removing the 32K VSAM 
dataset limit and reducing the frequency of switching SMF Datasets.

Has anyone done this?

If so, what has been your experience?

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html


Re: SMF and LOGSTREAM Datasets

2011-09-28 Thread Mark Jacobs
Haven't done it yet, but looking into it. There's a good redbook 
available on the topic.


Mark Jacobs


On 09/28/11 10:05, Henke, George wrote:

SMF data can now be sent to LOGSTREAM datasets thus removing the 32K VSAM 
dataset limit and reducing the frequency of switching SMF Datasets.

Has anyone done this?

If so, what has been your experience?

   

--
Mark Jacobs
Time Customer Service
Tampa, FL


Some people are electrifying, they light up
a room when they leave.

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html


Re: SMF and LOGSTREAM Datasets

2011-09-28 Thread Martinez, Frank J
I converted to LOGSTREAM with relative ease a few months back and I have not 
regretted it.  I followed a document called Migrating SMF from Data Set 
Recording to Log Stream Logging, and it worked like a charm.  I created 
several log streams (CICS, DB2, RMF, etc) and it has made life easier for all.


Frank J. Martinez
Technical Support Supervisor
IT System z

 
-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of 
Henke, George
Sent: Wednesday, September 28, 2011 10:06 AM
To: IBM-MAIN@bama.ua.edu
Subject: SMF and LOGSTREAM Datasets

SMF data can now be sent to LOGSTREAM datasets thus removing the 32K VSAM 
dataset limit and reducing the frequency of switching SMF Datasets.

Has anyone done this?

If so, what has been your experience?

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html


Re: SMF and LOGSTREAM Datasets

2011-09-28 Thread Pesce, Andy
Same experience here as well.  The white paper listed below was a great guide.  
I have some processes
that I run to offload the data once a day to a daily gdg.  I have not had any 
problems.

I would not suggest doing this for LOGREC, yet.  I encountered a lot of 
problems with running
reports.  Especially if there were no records selected.  I was getting 
permission errors.
IBM stated that it worked as designed.  So, I converted my LOGREC back to 
using SYS1.LOGREC.


-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of 
Martinez, Frank J
Sent: Wednesday, September 28, 2011 9:24 AM
To: IBM-MAIN@bama.ua.edu
Subject: Re: SMF and LOGSTREAM Datasets

I converted to LOGSTREAM with relative ease a few months back and I have not 
regretted it.  I followed a document called Migrating SMF from Data Set 
Recording to Log Stream Logging, and it worked like a charm.  I created 
several log streams (CICS, DB2, RMF, etc) and it has made life easier for all.


Frank J. Martinez
Technical Support Supervisor
IT System z

 
-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of 
Henke, George
Sent: Wednesday, September 28, 2011 10:06 AM
To: IBM-MAIN@bama.ua.edu
Subject: SMF and LOGSTREAM Datasets

SMF data can now be sent to LOGSTREAM datasets thus removing the 32K VSAM 
dataset limit and reducing the frequency of switching SMF Datasets.

Has anyone done this?

If so, what has been your experience?

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html


LOGREC LOGSTREAMS (was: SMF and LOGSTREAM Datasets

2011-09-28 Thread Jim Petersen
We use LOGREC LOGSTREAMS with no issues.   We offload it nightly to a GDG and 
create reports from that.
___
Jim Petersen
MVS - Lead Systems Engineer
Home Depot Technology Center
1300 Park Center Drive, Austin, TX 78753
www.homedepot.com
email:jim_peter...@homedepot.com
512-977-2615 direct
512-977-2930 fax
210-859-9887 cell phone

-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of 
Pesce, Andy
Sent: Wednesday, September 28, 2011 9:37 AM
To: IBM-MAIN@bama.ua.edu
Subject: Re: SMF and LOGSTREAM Datasets

Same experience here as well.  The white paper listed below was a great guide.  
I have some processes
that I run to offload the data once a day to a daily gdg.  I have not had any 
problems.

I would not suggest doing this for LOGREC, yet.  I encountered a lot of 
problems with running
reports.  Especially if there were no records selected.  I was getting 
permission errors.
IBM stated that it worked as designed.  So, I converted my LOGREC back to 
using SYS1.LOGREC.


-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of 
Martinez, Frank J
Sent: Wednesday, September 28, 2011 9:24 AM
To: IBM-MAIN@bama.ua.edu
Subject: Re: SMF and LOGSTREAM Datasets

I converted to LOGSTREAM with relative ease a few months back and I have not 
regretted it.  I followed a document called Migrating SMF from Data Set 
Recording to Log Stream Logging, and it worked like a charm.  I created 
several log streams (CICS, DB2, RMF, etc) and it has made life easier for all.


Frank J. Martinez
Technical Support Supervisor
IT System z


-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of 
Henke, George
Sent: Wednesday, September 28, 2011 10:06 AM
To: IBM-MAIN@bama.ua.edu
Subject: SMF and LOGSTREAM Datasets

SMF data can now be sent to LOGSTREAM datasets thus removing the 32K VSAM 
dataset limit and reducing the frequency of switching SMF Datasets.

Has anyone done this?

If so, what has been your experience?

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html




The information in this Internet Email is confidential and may be legally 
privileged. It is intended solely for the addressee. Access to this Email by 
anyone else is unauthorized. If you are not the intended recipient, any 
disclosure, copying, distribution or any action taken or omitted to be taken in 
reliance on it, is prohibited and may be unlawful. When addressed to our 
clients any opinions or advice contained in this Email are subject to the terms 
and conditions expressed in any applicable governing The Home Depot terms of 
business or client engagement letter. The Home Depot disclaims all 
responsibility and liability for the accuracy and content of this attachment 
and for any damages or losses arising from any inaccuracies, errors, viruses, 
e.g., worms, trojan horses, etc., or other items of a destructive nature, which 
may be contained in this attachment and shall not be liable for direct, 
indirect, consequential or special damages in connection with this e-mail 
message !
 or its attachment.

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html


Re: LOGREC LOGSTREAMS (was: SMF and LOGSTREAM Datasets

2011-09-28 Thread Martinez, Frank J
We do the same with LOGREC

Frank J. Martinez
Technical Support Supervisor
IT System z


-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of 
Jim Petersen
Sent: Wednesday, September 28, 2011 12:24 PM
To: IBM-MAIN@bama.ua.edu
Subject: LOGREC LOGSTREAMS (was: SMF and LOGSTREAM Datasets

We use LOGREC LOGSTREAMS with no issues.   We offload it nightly to a GDG and 
create reports from that.
___
Jim Petersen
MVS - Lead Systems Engineer
Home Depot Technology Center
1300 Park Center Drive, Austin, TX 78753
www.homedepot.com
email:jim_peter...@homedepot.com
512-977-2615 direct
512-977-2930 fax
210-859-9887 cell phone

-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of 
Pesce, Andy
Sent: Wednesday, September 28, 2011 9:37 AM
To: IBM-MAIN@bama.ua.edu
Subject: Re: SMF and LOGSTREAM Datasets

Same experience here as well.  The white paper listed below was a great guide.  
I have some processes
that I run to offload the data once a day to a daily gdg.  I have not had any 
problems.

I would not suggest doing this for LOGREC, yet.  I encountered a lot of 
problems with running
reports.  Especially if there were no records selected.  I was getting 
permission errors.
IBM stated that it worked as designed.  So, I converted my LOGREC back to 
using SYS1.LOGREC.


-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of 
Martinez, Frank J
Sent: Wednesday, September 28, 2011 9:24 AM
To: IBM-MAIN@bama.ua.edu
Subject: Re: SMF and LOGSTREAM Datasets

I converted to LOGSTREAM with relative ease a few months back and I have not 
regretted it.  I followed a document called Migrating SMF from Data Set 
Recording to Log Stream Logging, and it worked like a charm.  I created 
several log streams (CICS, DB2, RMF, etc) and it has made life easier for all.


Frank J. Martinez
Technical Support Supervisor
IT System z


-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of 
Henke, George
Sent: Wednesday, September 28, 2011 10:06 AM
To: IBM-MAIN@bama.ua.edu
Subject: SMF and LOGSTREAM Datasets

SMF data can now be sent to LOGSTREAM datasets thus removing the 32K VSAM 
dataset limit and reducing the frequency of switching SMF Datasets.

Has anyone done this?

If so, what has been your experience?

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html




The information in this Internet Email is confidential and may be legally 
privileged. It is intended solely for the addressee. Access to this Email by 
anyone else is unauthorized. If you are not the intended recipient, any 
disclosure, copying, distribution or any action taken or omitted to be taken in 
reliance on it, is prohibited and may be unlawful. When addressed to our 
clients any opinions or advice contained in this Email are subject to the terms 
and conditions expressed in any applicable governing The Home Depot terms of 
business or client engagement letter. The Home Depot disclaims all 
responsibility and liability for the accuracy and content of this attachment 
and for any damages or losses arising from any inaccuracies, errors, viruses, 
e.g., worms, trojan horses, etc., or other items of a destructive nature, which 
may be contained in this attachment and shall not be liable for direct, 
indirect, consequential or special damages in connection with this e-mail 
message !
 or its attachment.

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html


Re: SMF and LOGSTREAM Datasets

2011-09-28 Thread Elardus Engelbrecht
Pesce, Andy wrote:

I would not suggest doing this for LOGREC, yet.  I encountered a lot of 
problems with running reports.  Especially if there were no records 
selected.  I was getting permission errors.

Permission errors? It must be something I missed? Please tell me more about 
those 'permission' errors. 

Where do you get the errors? In LOGSTREAM putting EREP data there, using the 
datasets associated with LOGSTREAM or extracting it to your ACCUM datasets? 
RACF access? Usage of the utility using to define LOGSTREAM? 


IBM stated that it worked as designed.  So, I converted my LOGREC back to 
using SYS1.LOGREC.

Do you have any background documentation(s) for that 'WAD' thing? 
I'm on LOGSTREAM for LOGREC for many centuries, ok, wait, wait, make that 
'years'. :-D  :-D

I can't remember having any problems with it except estimating the storage (in 
Coupling Facility) way too small in the beginning.

To stay on topic, I plan to go on LOGSTREAM for SMF later when I'm rich and 
grown up... :-D

TIA!

Groete / Greetings
Elardus Engelbrecht

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html