Re: [External] Re: Vtoc and index sizing based on Mods

2020-07-06 Thread Allan Staller
There are still some minor issues involved w/vvds, etc. placement, but there 
are very moinr, and for most volumes will make zero difference.

-Original Message-
From: IBM Mainframe Discussion List  On Behalf Of 
Pommier, Rex
Sent: Monday, July 6, 2020 10:18 AM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: [External] Re: Vtoc and index sizing based on Mods

[CAUTION: This Email is from outside the Organization. Unless you trust the 
sender, Don’t click links or open attachments as it may be a Phishing email, 
which can steal your Information and compromise your Computer.]

Hi Peter,

I don't think anybody answered this question.  With modern (read: emulated) 
boxes I've been told the location of the VTOC/VTOCIX/VVDS don't matter anymore. 
 Back in the SLED days I was a stickler for placing the VTOC & IX  1/3 of the 
way into the volume, right next to each other to try to minimize head movement. 
 Now, with it all placed on "smoke and mirrors", and with huge cache sizes, the 
location doesn't matter, so I place them right at the beginning of the volumes 
so that I have the largest possible contiguous free space - at least until the 
first dataset on the volume is deleted.  :-)

Rex

-Original Message-
From: IBM Mainframe Discussion List  On Behalf Of 
Peter
Sent: Saturday, July 4, 2020 11:22 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: [External] Re: Vtoc and index sizing based on Mods

Hello

Thank you so much

How do we determine the location of vtoc and index ?  Is it possible to place 
all the mod 27 in same location of cylinder and tracks ?

On Sat, 4 Jul, 2020, 9:44 PM Lizette Koehler, 
wrote:

> It depends
>
> If the volume would have one dataset on it, like my SPOOL Volumes,
> then they are very small
>
> If like in my TSO Pool there are lots of tiny (15 track or less) then
> I make them huge.
>
> So it all depends on
>
> What the intent of the volume is (1 dataset vs Many Datasets) What
> size the volume is (Mod3/9/27/54/EAV)
>
> You will see an error message when the VTOC or VTOIX is too small.
>
>
>
> Hope this helps
>
> Lizette
>
>
> -Original Message-
> From: IBM Mainframe Discussion List  On
> Behalf Of Peter
> Sent: Saturday, July 4, 2020 10:12 AM
> To: IBM-MAIN@LISTSERV.UA.EDU
> Subject: Vtoc and index sizing based on Mods
>
> Hello Group
>
> Apology for being ignorant.
>
> Is there a formula or any constraints for initialising a specific dasd
> Mod ?
>
> How do arrive to a specific vtoc and index value while initialising a
> dasd ?
>
> Please help me to understand
>
> Peter
>
> --
> For IBM-MAIN subscribe / signoff / archive access instructions, send
> email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
>
> --
> For IBM-MAIN subscribe / signoff / archive access instructions, send
> email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
>

--
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
lists...@listserv.ua.edu with the message: INFO IBM-MAIN


The information contained in this message is confidential, protected from 
disclosure and may be legally privileged.  If the reader of this message is not 
the intended recipient or an employee or agent responsible for delivering this 
message to the intended recipient, you are hereby notified that any disclosure, 
distribution, copying, or any action taken or action omitted in reliance on it, 
is strictly prohibited and may be unlawful.  If you have received this 
communication in error, please notify us immediately by replying to this 
message and destroy the material in its entirety, whether in electronic or hard 
copy format.  Thank you.


--
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
lists...@listserv.ua.edu with the message: INFO IBM-MAIN
::DISCLAIMER::

The contents of this e-mail and any attachment(s) are confidential and intended 
for the named recipient(s) only. E-mail transmission is not guaranteed to be 
secure or error-free as information could be intercepted, corrupted, lost, 
destroyed, arrive late or incomplete, or may contain viruses in transmission. 
The e mail and its contents (with or without referred errors) shall therefore 
not attach any liability on the originator or HCL or its affiliates. Views or 
opinions, if any, presented in this email are solely those of the author and 
may not necessarily reflect the views or opinions of HCL or its affiliates. Any 
form of reproduction, dissemination, copying, disclosure, modification, 
distri

Re: [External] Re: Vtoc and index sizing based on Mods

2020-07-06 Thread Pommier, Rex
Hi Peter,

I don't think anybody answered this question.  With modern (read: emulated) 
boxes I've been told the location of the VTOC/VTOCIX/VVDS don't matter anymore. 
 Back in the SLED days I was a stickler for placing the VTOC & IX  1/3 of the 
way into the volume, right next to each other to try to minimize head movement. 
 Now, with it all placed on "smoke and mirrors", and with huge cache sizes, the 
location doesn't matter, so I place them right at the beginning of the volumes 
so that I have the largest possible contiguous free space - at least until the 
first dataset on the volume is deleted.  :-)

Rex

-Original Message-
From: IBM Mainframe Discussion List  On Behalf Of 
Peter
Sent: Saturday, July 4, 2020 11:22 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: [External] Re: Vtoc and index sizing based on Mods

Hello

Thank you so much

How do we determine the location of vtoc and index ?  Is it possible to place 
all the mod 27 in same location of cylinder and tracks ?

On Sat, 4 Jul, 2020, 9:44 PM Lizette Koehler, 
wrote:

> It depends
>
> If the volume would have one dataset on it, like my SPOOL Volumes, 
> then they are very small
>
> If like in my TSO Pool there are lots of tiny (15 track or less) then 
> I make them huge.
>
> So it all depends on
>
> What the intent of the volume is (1 dataset vs Many Datasets) What 
> size the volume is (Mod3/9/27/54/EAV)
>
> You will see an error message when the VTOC or VTOIX is too small.
>
>
>
> Hope this helps
>
> Lizette
>
>
> -Original Message-
> From: IBM Mainframe Discussion List  On 
> Behalf Of Peter
> Sent: Saturday, July 4, 2020 10:12 AM
> To: IBM-MAIN@LISTSERV.UA.EDU
> Subject: Vtoc and index sizing based on Mods
>
> Hello Group
>
> Apology for being ignorant.
>
> Is there a formula or any constraints for initialising a specific dasd 
> Mod ?
>
> How do arrive to a specific vtoc and index value while initialising a 
> dasd ?
>
> Please help me to understand
>
> Peter
>
> --
> For IBM-MAIN subscribe / signoff / archive access instructions, send 
> email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
>
> --
> For IBM-MAIN subscribe / signoff / archive access instructions, send 
> email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
>

--
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
lists...@listserv.ua.edu with the message: INFO IBM-MAIN


The information contained in this message is confidential, protected from 
disclosure and may be legally privileged.  If the reader of this message is not 
the intended recipient or an employee or agent responsible for delivering this 
message to the intended recipient, you are hereby notified that any disclosure, 
distribution, copying, or any action taken or action omitted in reliance on it, 
is strictly prohibited and may be unlawful.  If you have received this 
communication in error, please notify us immediately by replying to this 
message and destroy the material in its entirety, whether in electronic or hard 
copy format.  Thank you.


--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: Vtoc and index sizing based on Mods

2020-07-06 Thread Steve Smith
Simple formulae:

* # VTOC tracks = (max # datasets you want to have on the volume + max #
datasets with > 3 extents + max # EAS datasets + 5) / 50.
* # VTOCIX tracks = (max # datasets + 5) / 21;

I'd let SMS take care of the VVDS; it can grow if needed.

Things that should go without saying (because they're obvious):
1. If you don't know the inputs, then you'll have to estimate, or guess.
2. It's much better to make the VTOC & IX bigger than necessary than too
small.

sas

On Mon, Jul 6, 2020 at 7:01 AM R.S.  wrote:

> W dniu 04.07.2020 o 19:12, Peter pisze:
> > Hello Group
> >
> > Apology for being ignorant.
> >
> > Is there a formula or any constraints for initialising a specific dasd
> Mod ?
> >
> > How do arrive to a specific vtoc and index value while initialising a
> dasd ?
> >
> > Please help me to understand
> >
> >
>
> There is no formula. No *simple* formula. VTOC and VTOCIX size depends
> on data you plan to keep on the volume.
> Big number of small datasets will occupy more VTOC space. Single large
> dataset will take very little space.
>

>

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: Vtoc and index sizing based on Mods

2020-07-06 Thread R.S.

W dniu 04.07.2020 o 19:12, Peter pisze:

Hello Group

Apology for being ignorant.

Is there a formula or any constraints for initialising a specific dasd Mod ?

How do arrive to a specific vtoc and index value while initialising a dasd ?

Please help me to understand




There is no formula. No *simple* formula. VTOC and VTOCIX size depends 
on data you plan to keep on the volume.
Big number of small datasets will occupy more VTOC space. Single large 
dataset will take very little space.

Solution?
If you don't know to much about datasets just use your "defaults". What 
defaults? I would suggest to start from values used by IBM in ServerPac 
Installation.
Note: nowadays DASD is much cheaper than in the past. You may be more 
generous for VTOC.


--
Radoslaw Skorupka
Lodz, Poland





==

Jeśli nie jesteś adresatem tej wiadomości:

- powiadom nas o tym w mailu zwrotnym (dziękujemy!),
- usuń trwale tę wiadomość (i wszystkie kopie, które wydrukowałeś lub zapisałeś 
na dysku).
Wiadomość ta może zawierać chronione prawem informacje, które może wykorzystać 
tylko adresat.Przypominamy, że każdy, kto rozpowszechnia (kopiuje, rozprowadza) 
tę wiadomość lub podejmuje podobne działania, narusza prawo i może podlegać 
karze.

mBank S.A. z siedzibą w Warszawie, ul. Senatorska 18, 00-950 
Warszawa,www.mBank.pl, e-mail: kont...@mbank.pl. Sąd Rejonowy dla m. st. 
Warszawy XII Wydział Gospodarczy Krajowego Rejestru Sądowego, KRS 025237, 
NIP: 526-021-50-88. Kapitał zakładowy (opłacony w całości) według stanu na 
01.01.2020 r. wynosi 169.401.468 złotych.

If you are not the addressee of this message:

- let us know by replying to this e-mail (thank you!),
- delete this message permanently (including all the copies which you have 
printed out or saved).
This message may contain legally protected information, which may be used 
exclusively by the addressee.Please be reminded that anyone who disseminates 
(copies, distributes) this message or takes any similar action, violates the 
law and may be penalised.

mBank S.A. with its registered office in Warsaw, ul. Senatorska 18, 00-950 
Warszawa,www.mBank.pl, e-mail: kont...@mbank.pl. District Court for the Capital 
City of Warsaw, 12th Commercial Division of the National Court Register, KRS 
025237, NIP: 526-021-50-88. Fully paid-up share capital amounting to PLN 
169.401.468 as at 1 January 2020.

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: Vtoc and index sizing based on Mods

2020-07-05 Thread Graham Harris
...and if it's an SMS volume, you also need to concern yourself about VVDS
size.


On Sun, 5 Jul 2020 at 12:56, Mike Schwab  wrote:

> Here are the VTOC sizes needed for volumes full of 1 track datasets.
>
> https://www.ibm.com/support/knowledgecenter/en/SSLTBW_2.1.0/com.ibm.zos.v2r1.ickug00/ick40744.htm
>
>
> On Sun, Jul 5, 2020 at 4:22 AM Peter  wrote:
> >
> > Hello
> >
> > Thank you so much
> >
> > How do we determine the location of vtoc and index ?  Is it possible to
> > place all the mod 27 in same location of cylinder and tracks ?
> >
> > On Sat, 4 Jul, 2020, 9:44 PM Lizette Koehler, 
> > wrote:
> >
> > > It depends
> > >
> > > If the volume would have one dataset on it, like my SPOOL Volumes, then
> > > they are very small
> > >
> > > If like in my TSO Pool there are lots of tiny (15 track or less) then I
> > > make them huge.
> > >
> > > So it all depends on
> > >
> > > What the intent of the volume is (1 dataset vs Many Datasets)
> > > What size the volume is (Mod3/9/27/54/EAV)
> > >
> > > You will see an error message when the VTOC or VTOIX is too small.
> > >
> > >
> > >
> > > Hope this helps
> > >
> > > Lizette
> > >
> > >
> > > -Original Message-
> > > From: IBM Mainframe Discussion List  On
> Behalf
> > > Of Peter
> > > Sent: Saturday, July 4, 2020 10:12 AM
> > > To: IBM-MAIN@LISTSERV.UA.EDU
> > > Subject: Vtoc and index sizing based on Mods
> > >
> > > Hello Group
> > >
> > > Apology for being ignorant.
> > >
> > > Is there a formula or any constraints for initialising a specific dasd
> Mod
> > > ?
> > >
> > > How do arrive to a specific vtoc and index value while initialising a
> dasd
> > > ?
> > >
> > > Please help me to understand
> > >
> > > Peter
> > >
> > > --
> > > For IBM-MAIN subscribe / signoff / archive access instructions, send
> email
> > > to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
> > >
> > > --
> > > For IBM-MAIN subscribe / signoff / archive access instructions,
> > > send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
> > >
> >
> > --
> > For IBM-MAIN subscribe / signoff / archive access instructions,
> > send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
>
>
>
> --
> Mike A Schwab, Springfield IL USA
> Where do Forest Rangers go to get away from it all?
>
> --
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
>

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: Vtoc and index sizing based on Mods

2020-07-05 Thread Mike Schwab
Here are the VTOC sizes needed for volumes full of 1 track datasets.
https://www.ibm.com/support/knowledgecenter/en/SSLTBW_2.1.0/com.ibm.zos.v2r1.ickug00/ick40744.htm


On Sun, Jul 5, 2020 at 4:22 AM Peter  wrote:
>
> Hello
>
> Thank you so much
>
> How do we determine the location of vtoc and index ?  Is it possible to
> place all the mod 27 in same location of cylinder and tracks ?
>
> On Sat, 4 Jul, 2020, 9:44 PM Lizette Koehler, 
> wrote:
>
> > It depends
> >
> > If the volume would have one dataset on it, like my SPOOL Volumes, then
> > they are very small
> >
> > If like in my TSO Pool there are lots of tiny (15 track or less) then I
> > make them huge.
> >
> > So it all depends on
> >
> > What the intent of the volume is (1 dataset vs Many Datasets)
> > What size the volume is (Mod3/9/27/54/EAV)
> >
> > You will see an error message when the VTOC or VTOIX is too small.
> >
> >
> >
> > Hope this helps
> >
> > Lizette
> >
> >
> > -Original Message-
> > From: IBM Mainframe Discussion List  On Behalf
> > Of Peter
> > Sent: Saturday, July 4, 2020 10:12 AM
> > To: IBM-MAIN@LISTSERV.UA.EDU
> > Subject: Vtoc and index sizing based on Mods
> >
> > Hello Group
> >
> > Apology for being ignorant.
> >
> > Is there a formula or any constraints for initialising a specific dasd Mod
> > ?
> >
> > How do arrive to a specific vtoc and index value while initialising a dasd
> > ?
> >
> > Please help me to understand
> >
> > Peter
> >
> > --
> > For IBM-MAIN subscribe / signoff / archive access instructions, send email
> > to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
> >
> > --
> > For IBM-MAIN subscribe / signoff / archive access instructions,
> > send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
> >
>
> --
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN



-- 
Mike A Schwab, Springfield IL USA
Where do Forest Rangers go to get away from it all?

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: Vtoc and index sizing based on Mods

2020-07-04 Thread Seymour J Metz
The input to ICKDSF when you format the volume.


--
Shmuel (Seymour J.) Metz
http://mason.gmu.edu/~smetz3


From: IBM Mainframe Discussion List [IBM-MAIN@LISTSERV.UA.EDU] on behalf of 
Peter [dbajava...@gmail.com]
Sent: Sunday, July 5, 2020 12:22 AM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: Vtoc and index sizing based on Mods

Hello

Thank you so much

How do we determine the location of vtoc and index ?  Is it possible to
place all the mod 27 in same location of cylinder and tracks ?

On Sat, 4 Jul, 2020, 9:44 PM Lizette Koehler, 
wrote:

> It depends
>
> If the volume would have one dataset on it, like my SPOOL Volumes, then
> they are very small
>
> If like in my TSO Pool there are lots of tiny (15 track or less) then I
> make them huge.
>
> So it all depends on
>
> What the intent of the volume is (1 dataset vs Many Datasets)
> What size the volume is (Mod3/9/27/54/EAV)
>
> You will see an error message when the VTOC or VTOIX is too small.
>
>
>
> Hope this helps
>
> Lizette
>
>
> -Original Message-
> From: IBM Mainframe Discussion List  On Behalf
> Of Peter
> Sent: Saturday, July 4, 2020 10:12 AM
> To: IBM-MAIN@LISTSERV.UA.EDU
> Subject: Vtoc and index sizing based on Mods
>
> Hello Group
>
> Apology for being ignorant.
>
> Is there a formula or any constraints for initialising a specific dasd Mod
> ?
>
> How do arrive to a specific vtoc and index value while initialising a dasd
> ?
>
> Please help me to understand
>
> Peter
>
> --
> For IBM-MAIN subscribe / signoff / archive access instructions, send email
> to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
>
> --
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
>

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: Vtoc and index sizing based on Mods

2020-07-04 Thread Peter
Hello

Thank you so much

How do we determine the location of vtoc and index ?  Is it possible to
place all the mod 27 in same location of cylinder and tracks ?

On Sat, 4 Jul, 2020, 9:44 PM Lizette Koehler, 
wrote:

> It depends
>
> If the volume would have one dataset on it, like my SPOOL Volumes, then
> they are very small
>
> If like in my TSO Pool there are lots of tiny (15 track or less) then I
> make them huge.
>
> So it all depends on
>
> What the intent of the volume is (1 dataset vs Many Datasets)
> What size the volume is (Mod3/9/27/54/EAV)
>
> You will see an error message when the VTOC or VTOIX is too small.
>
>
>
> Hope this helps
>
> Lizette
>
>
> -Original Message-
> From: IBM Mainframe Discussion List  On Behalf
> Of Peter
> Sent: Saturday, July 4, 2020 10:12 AM
> To: IBM-MAIN@LISTSERV.UA.EDU
> Subject: Vtoc and index sizing based on Mods
>
> Hello Group
>
> Apology for being ignorant.
>
> Is there a formula or any constraints for initialising a specific dasd Mod
> ?
>
> How do arrive to a specific vtoc and index value while initialising a dasd
> ?
>
> Please help me to understand
>
> Peter
>
> --
> For IBM-MAIN subscribe / signoff / archive access instructions, send email
> to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
>
> --
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
>

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: Vtoc and index sizing based on Mods

2020-07-04 Thread Lizette Koehler
It depends

If the volume would have one dataset on it, like my SPOOL Volumes, then they 
are very small

If like in my TSO Pool there are lots of tiny (15 track or less) then I make 
them huge.

So it all depends on

What the intent of the volume is (1 dataset vs Many Datasets)
What size the volume is (Mod3/9/27/54/EAV)

You will see an error message when the VTOC or VTOIX is too small.



Hope this helps

Lizette


-Original Message-
From: IBM Mainframe Discussion List  On Behalf Of 
Peter
Sent: Saturday, July 4, 2020 10:12 AM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Vtoc and index sizing based on Mods

Hello Group

Apology for being ignorant.

Is there a formula or any constraints for initialising a specific dasd Mod ?

How do arrive to a specific vtoc and index value while initialising a dasd ?

Please help me to understand

Peter

--
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
lists...@listserv.ua.edu with the message: INFO IBM-MAIN

--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN


Re: Vtoc and index sizing based on Mods

2020-07-04 Thread Mike Schwab
IBM guidelines are to support a volume filled with minimum sized
datasets (1 track / 21 cylinders EAV).

https://www.ibm.com/support/knowledgecenter/en/SSLTBW_2.2.0/com.ibm.zos.v2r2.ickug00/ick40743.htm

On Sat, Jul 4, 2020 at 5:12 PM Peter  wrote:
>
> Hello Group
>
> Apology for being ignorant.
>
> Is there a formula or any constraints for initialising a specific dasd Mod ?
>
> How do arrive to a specific vtoc and index value while initialising a dasd ?
>
> Please help me to understand
>
> Peter
>
> --
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN



-- 
Mike A Schwab, Springfield IL USA
Where do Forest Rangers go to get away from it all?

--
For IBM-MAIN subscribe / signoff / archive access instructions,