Re: INPUT/OUTPUT CONFIGURATION

2011-07-22 Thread Carlos Bodra - Pessoal
You can just go to HMC and do a PCHID reassign from bad one to a good 
one in same or in another Escon Card.


Carlos Bodra
IBM Certified Specialist System z   
Sao Paulo - Brazil


Em 21/07/2011 16:32, Sherry Everhart escreveu:

Hello Everyone,
I am interested in knowing how to configure a "spare" ESCON channel to our
DASD so that if one of the existing eight shared channels goes belly-up
(like it did last week) we can just move the cable over and not have to
POR.

I'm currently looking in the "System z Input/Output Configuration Program
User's Guide for ICP IOCP" but I'm not sure what to look for.  I keep
getting this error when trying to add another channel:

  CHPID PCHID=160,PATH=(60),TYPE=CNC,SHARED
  CHPID PCHID=161,PATH=(61),TYPE=CNC,SHARED
  CHPID PCHID=162,PATH=(62),TYPE=CNC,SHARED
  CHPID PCHID=163,PATH=(63),TYPE=CNC,SHARED
  CHPID PCHID=166,PATH=(66),TYPE=CNC,SHARED
  CHPID PCHID=170,PATH=(70),TYPE=CNC,SHARED
  CHPID PCHID=171,PATH=(71),TYPE=CNC,SHARED
  CHPID PCHID=175,PATH=(75),TYPE=CNC,SHARED
  CHPID PCHID=176,PATH=(76),TYPE=CNC,SHARED
   CNTLUNIT CUNUMBR=0C00,PATH=(60,61,62,63,66,70,71,75,76),UNIT=3990,X
UNITADD=((00,256)),CUADD=0
*ICP  ICP115I DELIMITER ERROR, EXPECT RIGHT PARENTHESIS - ,76),UNI
  CNTLUNIT CUNUMBR=0D00,PATH=(60,61,62,63,66,70,71,75,76),UNIT=3990,X
UNITADD=((00,256)),CUADD=1
*ICP  ICP115I DELIMITER ERROR, EXPECT RIGHT PARENTHESIS - ,76),UNI
  CNTLUNIT CUNUMBR=0E00,PATH=(60,61,62,63,66,70,71,75,76),UNIT=3990,X
UNITADD=((00,256)),CUADD=2
*ICP  ICP115I DELIMITER ERROR, EXPECT RIGHT PARENTHESIS - ,76),UNI
  CNTLUNIT CUNUMBR=0F00,PATH=(60,61,62,63,66,70,71,75,76),UNIT=3990,X
UNITADD=((00,256)),CUADD=3
*ICP  ICP115I DELIMITER ERROR, EXPECT RIGHT PARENTHESIS - ,76),UNI
  IODEVICE ADDRESS=(0D00,256),CUNUMBR=(0C00),   X
UNIT=3380,UNITADD=00
  IODEVICE ADDRESS=(0E00,256),CUNUMBR=(0D00),   X
UNIT=3380,UNITADD=00
  IODEVICE ADDRESS=(0F00,256),CUNUMBR=(0E00),   X
UNIT=3390,UNITADD=00
  IODEVICE ADDRESS=(1000,256),CUNUMBR=(0F00),   X
UNIT=3390,UNITADD=00
The error message states:  "IOCP expected a right parentheses as the first
character of string .  This error can occur if a keyword value
contains too many characters or if more parameters than your CPC supports
were specified."

Is it possible to configure a spare channel for redundancy?

Thanks for the help.

Sherry E.


Re: INPUT/OUTPUT CONFIGURATION

2011-07-21 Thread Alan Altmark
On Thursday, 07/21/2011 at 03:32 EDT, Sherry Everhart 
 wrote:
> I am interested in knowing how to configure a "spare" ESCON channel to 
our
> DASD so that if one of the existing eight shared channels goes belly-up
> (like it did last week) we can just move the cable over and not have to
> POR.
> 
> I'm currently looking in the "System z Input/Output Configuration 
Program 
> User's Guide for ICP IOCP" but I'm not sure what to look for. 

IOCP is complaining because you are trying to assign more than 8 paths to 
a Control Unit. (See Machine Limits appendix.)  The service rep will use 
PCHID/CHPID reassignment on the SE to logically move the CHPID associated 
with the failing port (PCHID) to a good port on the *same card*.

Check out the IBM System z Connectivity Handbook (redbook).  It has an 
extensive discussion on ESCON channel sparing.

Alan Altmark

Senior Managing z/VM and Linux Consultant
IBM System Lab Services and Training 
ibm.com/systems/services/labservices 
office: 607.429.3323
mobile; 607.321.7556
alan_altm...@us.ibm.com
IBM Endicott


Re: INPUT/OUTPUT CONFIGURATION

2011-07-21 Thread Sherry Everhart
"Reassigning the selected channel path identifier (CHPID) to another 
partition could not be completed.  The selected CHPID is not 
reconfigurable.  Select a reconfigurable CHPID and try the operation 
again."


Re: INPUT/OUTPUT CONFIGURATION

2011-07-21 Thread August Carideo
you can do a channel reassign at the HMC level also



   
 Sherry Everhart   
  To 
 Sent by: The IBM  IBMVM@LISTSERV.UARK.EDU 
 z/VM Operating cc 
 System
   INPUT/OUTPUT CONFIGURATION  
   
   
 07/21/2011 03:32  
 PM
   
   
 Please respond to 
   The IBM z/VM
 Operating System  
   
   
   




Hello Everyone,
I am interested in knowing how to configure a "spare" ESCON channel to ou
r
DASD so that if one of the existing eight shared channels goes belly-up

(like it did last week) we can just move the cable over and not have to

POR.

I'm currently looking in the "System z Input/Output Configuration Program

User's Guide for ICP IOCP" but I'm not sure what to look for.  I keep
getting this error when trying to add another channel:

 CHPID PCHID=160,PATH=(60),TYPE=CNC,SHARED
 CHPID PCHID=161,PATH=(61),TYPE=CNC,SHARED
 CHPID PCHID=162,PATH=(62),TYPE=CNC,SHARED
 CHPID PCHID=163,PATH=(63),TYPE=CNC,SHARED
 CHPID PCHID=166,PATH=(66),TYPE=CNC,SHARED
 CHPID PCHID=170,PATH=(70),TYPE=CNC,SHARED
 CHPID PCHID=171,PATH=(71),TYPE=CNC,SHARED
 CHPID PCHID=175,PATH=(75),TYPE=CNC,SHARED
 CHPID PCHID=176,PATH=(76),TYPE=CNC,SHARED
  CNTLUNIT CUNUMBR=0C00,PATH=(60,61,62,63,66,70,71,75,76),UNIT=3990
,X
   UNITADD=((00,256)),CUADD=0

*ICP  ICP115I DELIMITER ERROR, EXPECT RIGHT PARENTHESIS - ,76),UNI

 CNTLUNIT CUNUMBR=0D00,PATH=(60,61,62,63,66,70,71,75,76),UNIT=3990,
X
   UNITADD=((00,256)),CUADD=1

*ICP  ICP115I DELIMITER ERROR, EXPECT RIGHT PARENTHESIS - ,76),UNI

 CNTLUNIT CUNUMBR=0E00,PATH=(60,61,62,63,66,70,71,75,76),UNIT=3990,
X
   UNITADD=((00,256)),CUADD=2

*ICP  ICP115I DELIMITER ERROR, EXPECT RIGHT PARENTHESIS - ,76),UNI

 CNTLUNIT CUNUMBR=0F00,PATH=(60,61,62,63,66,70,71,75,76),UNIT=3990,
X
   UNITADD=((00,256)),CUADD=3

*ICP  ICP115I DELIMITER ERROR, EXPECT RIGHT PARENTHESIS - ,76),UNI

 IODEVICE ADDRESS=(0D00,256),CUNUMBR=(0C00),
  X
   UNIT=3380,UNITADD=00


 IODEVICE ADDRESS=(0E00,256),CUNUMBR=(0D00),
  X
   UNIT=3380,UNITADD=00


 IODEVICE ADDRESS=(0F00,256),CUNUMBR=(0E00),
  X
   UNIT=3390,UNITADD=00


 IODEVICE ADDRESS=(1000,256),CUNUMBR=(0F00),
  X
   UNIT=3390,UNITADD=00


The error message states:  "IOCP expected a right parentheses as the firs
t
character of string .  This error can occur if a keyword value

contains too many characters or if more parameters than your CPC supports

were specified."

Is it possible to configure a spare channel for redundancy?

Thanks for the help.

Sherry E.


Re: INPUT/OUTPUT CONFIGURATION

2011-07-21 Thread Davis, Larry (National VM/VSE Capability)
The HMC or SE has the ability to do this, or used to so a ESCON port could be 
sparred over to another port.
That way you did not have to code it in the IOCP. 

Larry Davis


-Original Message-
From: The IBM z/VM Operating System [mailto:IBMVM@LISTSERV.UARK.EDU] On Behalf 
Of Sherry Everhart
Sent: Thursday, July 21, 2011 3:32 PM
To: IBMVM@LISTSERV.UARK.EDU
Subject: INPUT/OUTPUT CONFIGURATION

Hello Everyone,
I am interested in knowing how to configure a "spare" ESCON channel to our 
DASD so that if one of the existing eight shared channels goes belly-up 
(like it did last week) we can just move the cable over and not have to 
POR.

I'm currently looking in the "System z Input/Output Configuration Program 
User's Guide for ICP IOCP" but I'm not sure what to look for.  I keep 
getting this error when trying to add another channel:

 CHPID PCHID=160,PATH=(60),TYPE=CNC,SHARED
 CHPID PCHID=161,PATH=(61),TYPE=CNC,SHARED
 CHPID PCHID=162,PATH=(62),TYPE=CNC,SHARED
 CHPID PCHID=163,PATH=(63),TYPE=CNC,SHARED
 CHPID PCHID=166,PATH=(66),TYPE=CNC,SHARED
 CHPID PCHID=170,PATH=(70),TYPE=CNC,SHARED
 CHPID PCHID=171,PATH=(71),TYPE=CNC,SHARED
 CHPID PCHID=175,PATH=(75),TYPE=CNC,SHARED
 CHPID PCHID=176,PATH=(76),TYPE=CNC,SHARED
  CNTLUNIT CUNUMBR=0C00,PATH=(60,61,62,63,66,70,71,75,76),UNIT=3990,X
   UNITADD=((00,256)),CUADD=0   
*ICP  ICP115I DELIMITER ERROR, EXPECT RIGHT PARENTHESIS - ,76),UNI  
 CNTLUNIT CUNUMBR=0D00,PATH=(60,61,62,63,66,70,71,75,76),UNIT=3990,X
   UNITADD=((00,256)),CUADD=1   
*ICP  ICP115I DELIMITER ERROR, EXPECT RIGHT PARENTHESIS - ,76),UNI  
 CNTLUNIT CUNUMBR=0E00,PATH=(60,61,62,63,66,70,71,75,76),UNIT=3990,X
   UNITADD=((00,256)),CUADD=2   
*ICP  ICP115I DELIMITER ERROR, EXPECT RIGHT PARENTHESIS - ,76),UNI  
 CNTLUNIT CUNUMBR=0F00,PATH=(60,61,62,63,66,70,71,75,76),UNIT=3990,X
   UNITADD=((00,256)),CUADD=3   
*ICP  ICP115I DELIMITER ERROR, EXPECT RIGHT PARENTHESIS - ,76),UNI  
 IODEVICE ADDRESS=(0D00,256),CUNUMBR=(0C00),   X
   UNIT=3380,UNITADD=00 
 IODEVICE ADDRESS=(0E00,256),CUNUMBR=(0D00),   X
   UNIT=3380,UNITADD=00 
 IODEVICE ADDRESS=(0F00,256),CUNUMBR=(0E00),   X
   UNIT=3390,UNITADD=00 
 IODEVICE ADDRESS=(1000,256),CUNUMBR=(0F00),   X
   UNIT=3390,UNITADD=00 
The error message states:  "IOCP expected a right parentheses as the first 
character of string .  This error can occur if a keyword value 
contains too many characters or if more parameters than your CPC supports 
were specified."

Is it possible to configure a spare channel for redundancy?

Thanks for the help.

Sherry E.


INPUT/OUTPUT CONFIGURATION

2011-07-21 Thread Sherry Everhart
Hello Everyone,
I am interested in knowing how to configure a "spare" ESCON channel to ou
r 
DASD so that if one of the existing eight shared channels goes belly-up 

(like it did last week) we can just move the cable over and not have to 

POR.

I'm currently looking in the "System z Input/Output Configuration Program
 
User's Guide for ICP IOCP" but I'm not sure what to look for.  I keep 
getting this error when trying to add another channel:

 CHPID PCHID=160,PATH=(60),TYPE=CNC,SHARED
 CHPID PCHID=161,PATH=(61),TYPE=CNC,SHARED
 CHPID PCHID=162,PATH=(62),TYPE=CNC,SHARED
 CHPID PCHID=163,PATH=(63),TYPE=CNC,SHARED
 CHPID PCHID=166,PATH=(66),TYPE=CNC,SHARED
 CHPID PCHID=170,PATH=(70),TYPE=CNC,SHARED
 CHPID PCHID=171,PATH=(71),TYPE=CNC,SHARED
 CHPID PCHID=175,PATH=(75),TYPE=CNC,SHARED
 CHPID PCHID=176,PATH=(76),TYPE=CNC,SHARED
  CNTLUNIT CUNUMBR=0C00,PATH=(60,61,62,63,66,70,71,75,76),UNIT=3990
,X
   UNITADD=((00,256)),CUADD=0  
 
*ICP  ICP115I DELIMITER ERROR, EXPECT RIGHT PARENTHESIS - ,76),UNI   
   
 CNTLUNIT CUNUMBR=0D00,PATH=(60,61,62,63,66,70,71,75,76),UNIT=3990,
X
   UNITADD=((00,256)),CUADD=1  
 
*ICP  ICP115I DELIMITER ERROR, EXPECT RIGHT PARENTHESIS - ,76),UNI   
   
 CNTLUNIT CUNUMBR=0E00,PATH=(60,61,62,63,66,70,71,75,76),UNIT=3990,
X
   UNITADD=((00,256)),CUADD=2  
 
*ICP  ICP115I DELIMITER ERROR, EXPECT RIGHT PARENTHESIS - ,76),UNI   
   
 CNTLUNIT CUNUMBR=0F00,PATH=(60,61,62,63,66,70,71,75,76),UNIT=3990,
X
   UNITADD=((00,256)),CUADD=3  
 
*ICP  ICP115I DELIMITER ERROR, EXPECT RIGHT PARENTHESIS - ,76),UNI   
   
 IODEVICE ADDRESS=(0D00,256),CUNUMBR=(0C00), 
  X
   UNIT=3380,UNITADD=00
 

 IODEVICE ADDRESS=(0E00,256),CUNUMBR=(0D00), 
  X
   UNIT=3380,UNITADD=00
 

 IODEVICE ADDRESS=(0F00,256),CUNUMBR=(0E00), 
  X
   UNIT=3390,UNITADD=00
 

 IODEVICE ADDRESS=(1000,256),CUNUMBR=(0F00), 
  X
   UNIT=3390,UNITADD=00
 

The error message states:  "IOCP expected a right parentheses as the firs
t 
character of string .  This error can occur if a keyword value 

contains too many characters or if more parameters than your CPC supports
 
were specified."

Is it possible to configure a spare channel for redundancy?

Thanks for the help.

Sherry E.