Hi Christian,
Thanks a lot for letting me know solution. It helps a lot.
I will use customworkspace, that suits better.
Thanks for pointing at the proper site Docs.
regards
Somshekar
Regards
Somshekar C Kadam
9036660538
On Fri, May 4, 2018 at 8:17 PM, <
christian.beushau...@continental-corporation.com> wrote:
> Hi Somshekar,
>
> We had the same issue with our build environment and I saw that we had 2
> possible solutions.
> 1.
> https://wiki.jenkins.io/display/JENKINS/Features+controlled+by+system+
> properties
> amongst others gives you hudson.slaves.WorkspaceList which you can change
> to set a different token.
> 2. use a ws(){} block in your pipeline to change to a different workspace.
> (for declarative Pipeline this is the customWorkspace option of the agent
> keyword (see. https://jenkins.io/doc/book/pipeline/syntax/#agent)
>
> Since I don't control the Jenkins master in our project I used the second
> approach. Especially since I am building in parallel on the same node I am
> reusing the original workspace and all checked out sources and build in a
> new subdirectory of the workspace.
>
> Hope this helps.
> Christian
>
> jenkinsci-users@googlegroups.com schrieb am 04.05.2018 07:53:42:
>
> > Von: Somshekar C Kadam
> > An: jenkinsci-users@googlegroups.com
> > Datum: 04.05.2018 07:54
> > Betreff: Parallel Build issue
> > Gesendet von: jenkinsci-users@googlegroups.com
> >
> > Hi All,
> >
> > I have setup a parallel build using data pipeline. This build
> > machine is on VM.
> >
> >
> > pipeline {
> >
> > stages {
> >
> > stage('ParallelBuild') {
> >
> >parallel {
> >
> > stage(‘BuildIntel’) {
> > agent {
> >..
> >;;;
> >
> >stage(‘BuildArm’) {
> >agent {
> >
> >
> > Workspace for Intel
> >
> > [‘BuildIntel’]
> > [CYELP_feature-3WJHZSTZRAESMPGCATYIL555HUF7XSCPTK2GXMGWNX7W5MCBMX4A]
> >
> > Workspace for Arm
> > [‘BuildARM’]
> > [CYELP_feature-3WJHZSTZRAESMPGCATYIL555HUF7XSCPTK2GXMGWNX7W5MCBMX4A@2
> >
> > Build for Arm is failing
> > [‘BuildARM’] Error, you have an invalid character (@) in your
> > COREBASE directory path. Please move the installation to a directory
> > which doesn't include any @ characters.
> >
> > as it is same workspace dir wit @2 extra
> >
> > to make it build I can create a separate dir in workspace and proceed.
> > Is it the right solution or any other fix is better please suggest
> >
> > thanks in advance
> >
> > Regards
> > Somshekar C Kadam
> >
> > --
> > You received this message because you are subscribed to the Google
> > Groups "Jenkins Users" group.
> > To unsubscribe from this group and stop receiving emails from it,
> > send an email to jenkinsci-users+unsubscr...@googlegroups.com.
> > To view this discussion on the web visit https://groups.google.com/
> > d/msgid/jenkinsci-users/CALbGK-pAedn1a8aeFaMYq%3DPWsG44JvjRsqaOe_f-
> > zUkYLHitWQ%40mail.gmail.com.
> > For more options, visit https://groups.google.com/d/optout.
>
> Mit freundlichen Gruessen/Best regards,
>
> Christian Beushausen
> I S&T PD SW SWF
> Interior Systems & Technology
>
> Besucheradresse / Visitor address:
> Continental Automotive GmbH
> Philipsstrasse 1, 35576 Wetzlar, Germany
>
> Rechnungsadresse / Invoice address:
> Continental Automotive GmbH
> Philipsstrasse 1, 35576 Wetzlar, Germany
>
> Telefon/Phone: +49 6441 370-9031
> Mobile: +49 151 74660227
> Telefax: +49 6441 37013-9031
> E-Mail: christian.beushau...@continental-corporation.com
>
> http://www.continental-automotive.com
>
>
> Continental Automotive GmbH, Vahrenwalder Str. 9, D-30165 Hannover
> Vorsitzender des Aufsichtsrats/Chairman of the Supervisory Board: Helmut
> Matschi
> Geschaeftsfuehrer/Managing Director: Georg Sistermanns, Harald Stuhlmann
> Sitz der Gesellschaft/Registered Office: Hannover
> Registergericht/Registered Court: Amtsgericht Hannover, HRB 59424
> USt.-ID-Nr./VAT-ID-No. DE814950663
>
>
> Proprietary and confidential. Distribution only by express authority of
> Continental AG or its subsidiaries.
>
> --
> You received this message because you are subscribed to the Google Groups
> "Jenkins Users" group.
> To unsubscribe from this group and stop receiving emails from it, send an
> email to jenkinsci-users+unsubscr...@googlegroups.com.
> To view this discussion on the web visit https://groups.google.com/d/
> msgid/jenkinsci-users/OF2CDE8E6F.F579456E-ONC1258283.0050379E-C1258283.
> 00514802%40continental-corporation.com.
> For more options, visit https://groups.google.com/d/optout.
>
--
You received this message because you are subscribed to the Google Groups
"Jenkins Users" group.
To unsubscribe from this group and stop rec