Boris Barbour a écrit :
Hi,
Is it possible to join a track to a net without starting drawing on
the net in question? In other words, if I start tracing in the middle
of nowhere, the track is assigned to Net:0/noname. It is then
impossible to join it to another net with DRC on (I get the
ErrType(16) of the subject); with DRC off I can make the join, but the
track retains its null net and will evermore generate DRC errors.
Is there a way to induce Kicad to change the net name once the join is
made, either automatically or manually?
In case you are wondering why I should want to do this, the issue
arises most often when drawing guarding and shielding traces. I've
managed to work around the problem so far, but not without difficulty.
Best wishes
Boris
Just open netlist dialog and run Rebuild Board Connectivity
--
Jean-Pierre CHARRAS
Maître de conférences
Directeur d'études 2ieme année.
Génie Electrique et Informatique Industrielle 2
Institut Universitaire de Technologie 1 de Grenoble
BP 67, 38402 St Martin d'Heres Cedex
Recherche :
Grenoble Image Parole Signal Automatique (GIPSA - INPG)
Grenoble France