Re: CSH202/CS test--strange

2004-10-11 Thread Ode Coyote

  The peroxide converts ions into particles and particles don't conduct.
 Conductivity goes down.
The TE greatly increases when peroxide is used in clear strong CS that had
little TE.

 TE might decrease in yellow CS as the existing larger particles break up
and overall conductivity stay the same after a few fluctuations. [Same PPM
in particles...different particle size..different light characteristics]

 None of this is very clear and is full of exceptions that haven't been
nailed down.  CS isn't just CS..it's all a little different even from batch
to batch, day to day.
 Environment has an effect on the process and the CS itself..sometimes
dramatic.

Ode

At 07:54 PM 10/9/2004 -0600, you wrote:
A simple test to try to see what H202 does when added to CS-
1cc 3% H202 was added 6 oz .8 uS distilled water = the uS went up 1.2  
to 2.0 uS

1cc 3% H202 added to 6 oz clear CS of 7.3 uS = the uS went up 1.2  to 8.5 uS

1cc 3% H202 added to 6 oz yellow CS of 11.2 uS  = the uS immediately 
DROPPED to 8.3 uS  (the CS did clear up)
   after a day and a half the uS had risen to 11.0 uS

The third result is weird---always before the uS has only gone up when I 
have added H202 to CS. I've never done this test with measured amounts 
before, but I have added H202 to CS after first measuring the uS of the 
CS, and it has gone up. I thought to a higher reading than the uS 
reading of the peroxide itself. I now question this. But why would it 
drop when the peroxide has conductance of its own to add?

What happened?
sol


--
The Silver List is a moderated forum for discussing Colloidal Silver.

Instructions for unsubscribing are posted at: http://silverlist.org

To post, address your message to: silver-list@eskimo.com
Silver List archive: http://escribe.com/health/thesilverlist/index.html

Address Off-Topic messages to: silver-off-topic-l...@eskimo.com
OT Archive: http://escribe.com/health/silverofftopiclist/index.html

List maintainer: Mike Devour mdev...@eskimo.com




Re: CSH202/CS test--strange

2004-10-11 Thread sol
I did not check TE. I find it too subjective for me, and I'm just not 
good at any but very broad differences in TE. 

I believed that H202 converted particles into ions, raising the 
conductivity. I just read somewhere that Frank Key has said this is the 
way it works, thus he does not recommend adding peroxide to his 
Mesosilver, as it will break the particles into ions. Can't recall where 
I read it.


All I know is I am now more puzzled than ever. Just once I'd like to get 
a repeatable result.

sol

Ode Coyote wrote:


 The peroxide converts ions into particles and particles don't conduct.
Conductivity goes down.
The TE greatly increases when peroxide is used in clear strong CS that had
little TE.

TE might decrease in yellow CS as the existing larger particles break up
and overall conductivity stay the same after a few fluctuations. [Same PPM
in particles...different particle size..different light characteristics]

None of this is very clear and is full of exceptions that haven't been
nailed down.  CS isn't just CS..it's all a little different even from batch
to batch, day to day.
Environment has an effect on the process and the CS itself..sometimes
dramatic.

Ode

 

 




--
The Silver List is a moderated forum for discussing Colloidal Silver.

Instructions for unsubscribing are posted at: http://silverlist.org

To post, address your message to: silver-list@eskimo.com
Silver List archive: http://escribe.com/health/thesilverlist/index.html

Address Off-Topic messages to: silver-off-topic-l...@eskimo.com
OT Archive: http://escribe.com/health/silverofftopiclist/index.html

List maintainer: Mike Devour mdev...@eskimo.com


CSH202/CS test--strange

2004-10-09 Thread sol

A simple test to try to see what H202 does when added to CS-
1cc 3% H202 was added 6 oz .8 uS distilled water = the uS went up 1.2  
to 2.0 uS


1cc 3% H202 added to 6 oz clear CS of 7.3 uS = the uS went up 1.2  to 8.5 uS

1cc 3% H202 added to 6 oz yellow CS of 11.2 uS  = the uS immediately 
DROPPED to 8.3 uS  (the CS did clear up)

  after a day and a half the uS had risen to 11.0 uS

The third result is weird---always before the uS has only gone up when I 
have added H202 to CS. I've never done this test with measured amounts 
before, but I have added H202 to CS after first measuring the uS of the 
CS, and it has gone up. I thought to a higher reading than the uS 
reading of the peroxide itself. I now question this. But why would it 
drop when the peroxide has conductance of its own to add?


What happened?
sol


--
The Silver List is a moderated forum for discussing Colloidal Silver.

Instructions for unsubscribing are posted at: http://silverlist.org

To post, address your message to: silver-list@eskimo.com
Silver List archive: http://escribe.com/health/thesilverlist/index.html

Address Off-Topic messages to: silver-off-topic-l...@eskimo.com
OT Archive: http://escribe.com/health/silverofftopiclist/index.html

List maintainer: Mike Devour mdev...@eskimo.com