[Observium] Capture gaps when retrieving interface traffic data …

2024-03-18 Thread Stefan Schmidt via observium
Hello! We query with snmp Observium the port data from a Mikrotik router (CCR2004-16G-2S+) with RouterOS 7.14.1 (Level 6) via SNMP from 4 WAN interfaces with polling and alerts. However, we always have gaps in the data. Every now and then 5-10 minutes of data are missing, so that vertical lines

[Observium] Re: Capture gaps when retrieving interface traffic data …

2024-03-18 Thread Stefan Schmidt via observium
Hello Admin, thank you for the 3 points, to which we would like to respond in order to further assess the problem: 1. The poller hardware currently only queries this one Mikrotik router beside 19 other devices behind. There is a load, this one router is displayed with “Last Polled” 100% and 2

[Observium] Re: Capture gaps when retrieving interface traffic data …

2024-03-19 Thread Stefan Schmidt via observium
Thx James Tandy, Solution! We selected the dedicated device, choosed "Properties" and "SNMP" Tap, then "Basic Configuration" and adjusted under "Max Repetitions" with the Value "80". Working better now, Poller Times went down to 50 Seconds ... Grüße Stefan __