Hi Angel,
it's looking not so bad, similar messages i have on my * server and, in
spite of it, * is working almost ideally.
Send us more info about problems.
Konrad
Angel Diaz wrote:
*CLI> Jun 22 20:37:55 NOTICE[1133718080]: chan_zap.c:4881
handle_init_event: Alarm cleared on channel 1
Jun 22 2
Paulo Mannheimer wrote:
l but couldn't figure out what bits should we try to set to test other
card options.
Is there any documentation on the card that could help us?
Hi Paulo,
try link (its about chip DS21[35]54 on e100p):
http://www.maxim-ic.com/appnotes.cfm?appnote_number=481
afaik wct1xxp d
[EMAIL PROTECTED] wrote:
Hi
I have Asterisk with two E100P cards
One connected to PSTN and other to my local PBX
I'm running into problem with faxes.
Faxes are connected to PBX and asterisk should just bridge the fax call
from one span to another.
Problem is that even if the fax image reach t
Nicholas Bachmann wrote:
Howdy -
I'm trying to get a Malaysian PRI E1 up on a TE410P, with no luck.
Right now, the setup is
Telco -> HDSL -> WorldDSL UTU801-> 2 BNC E1 -> balun -> crossover ->
TE410P
Right now, the CSU/DSU-ish WorldDSL box has a green light indicating
E1 sync, but the TE410
Brian Capouch wrote:
Stephen R. Besch wrote:
I have now tested a (previously suggested) method for doing
supervised transfers using the Grandstream SIP phone. It isn't
perfect, but it works and is very functional. Here are the steps:
When I try this, all goes well until, after putting the orig
Hi Lele,
that did the work.
now my telco is happy too.
many thanks
Konrad
Lele Forzani wrote:
We connected an * box with an e100p to an E1/PRI from a telco here in Italy.
After we had it working perfectly the telco told us that, despite the circuit
appeared to work fine, and we could place calls
Hi Alex,
About:
> WARNING[12301]: File chan_zap.c, Line 5342 (zt_pri_error): PRI: Read
on 203 failed: Unknown error 500
Similar warnings on my system are generated due to shared IRQ t1xxp and
ide0 (/proc/interrupts).
Just my 0.02$
Konrad
-Original Message-
From: [EMAIL PROTECTED]
[mail
Hi,
Zhone say yes, try:
http://www.zhone.com/support/technical_support/zplex/product_documents/ug_0011_10b.pdf
I try this and have stopped on
login and password. Zhone defaults are changed, answer
from seller - “it’s not possible” and I hold it. I can’t
take risk to reset zplex-software
crc ? Try:
span=1,0,0,ccs,hdb3,crc4
Konrad
-Original Message-
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of
[EMAIL PROTECTED]
Sent: Friday, March 07, 2003 3:03 AM
To: [EMAIL PROTECTED]
Subject: [Asterisk-Users] Re: Tormenta ISA E1 card
If I comment all lines of zaptel.co