Re: [Asterisk-Users] possible solution to PRI T100P dropped call issue

2004-01-11 Thread Walker Haddock
I have a T100P connected to an xspedius T1. We occasionally have calls disconnect. I just ran zttool and I get Tx/Rx Levels as 0/2. My zaptel.conf has --> span=1,0,0,esf,b8zs I can switch out the T100P and see what happens and report back. Walker On Sun, Jan 11, 2004 at 07:07:07PM -0700, Jo

[Asterisk-Users] possible solution to PRI T100P dropped call issue

2004-01-11 Thread John Brown (CV)
To recap: T100P card wouldn't sync with the telco using line side clocking ( span=1,1,0.) Had to use internal clocking (span=1,0,0...) zttool showed Tx/Rx Levels as 0/ 1 For the grins of it I replaced the T100P card with another newer card from inventory. This newer card has