Hi All,
i´ve dealed around with two E400P Cards the last 3 Days and I cant
figure out why this problem exists.
Here the description:
I have two E400P Quad E1 Cards. One is in NT Mode and the other is in
TE(CPE) Mode.
When I connect both cards via E1-Cross Cabel the cards wont sync. I see
in
On Fri, Apr 04, 2008 at 11:52:33AM +0200, Bernhard Wessels wrote:
Hi All,
i´ve dealed around with two E400P Cards the last 3 Days and I cant
figure out why this problem exists.
Here the description:
I have two E400P Quad E1 Cards. One is in NT Mode and the other is in
TE(CPE) Mode.
Just my guess:
None of the spans (ports) is configured to provide clock to the other
side.
If you want to cross-connect port 1 and port 2, you should use something
like:
span=1,1,4,ccs,hdb3,crc4
span=2,0,4,ccs,hdb3,crc4
(And run ztcfg after that)
Yes i know. The NT System is providing the
Seems to me that someting is wrong in layer1 setup. dont know why both
e400p cant sync. but they sync with rhino card?!?!
Strange.