[Bacula-users] SLES9 x64 ONLY intermittent bsock error and fails job. 50% of the time the jobs work all other clients work fine

2011-01-04 Thread Paul Hanson
Hi, I have an installation that was previously using version 2.4.4 and was upgraded to 5.0.3 with good success. However, there was a previous problem with the SLES9 x64 clients that would intermittently fail the jobs due to bsock errors. So the error has carried forward from 2.4.4 to 5.0.3 and

[Bacula-users] Howto limit job concurrency on individual tape drives within a library

2009-03-28 Thread Paul Hanson
Currently we have an IBM TS3200 working very well over fibre channel and has two Ultrium 4 tape units. If I set concurrency to two (2) then both tape units can work fine. However, if only one tape unit is in operation and two jobs start for the SAME tape pool, then the jobs are interlaced and I wou