On Mon, 15 Mar 2010 13:37:48 +1100
Norberto Meijome numard...@gmail.com wrote:
Any time you add/remove tapes from the tape library, you need to do
'update slots' and 'label barcodes' in bacula.
Does that not behave as you expect?
--
Alex Chekholko ch...@pcbi.upenn.edu
@
Yes, if you only have one drive, you need to have no jobs running in order to
do 'update slots' or 'label barcodes'.
I think you can update slots with the single drive running jobs. You
can not label barcodes however.
John
John Drescher wrote:
I think you can update slots with the single drive running jobs. You
can not label barcodes however.
I can confirm this, as I did this a couple of days ago, although watch
out for the size of the emailed job report, which for me was just under
4MB and contained thousands
Hi everyone,
We have a tape library, 7 slots, 1 drive, barcode reader. All our tapes are
barcoded.
I've been using 'label barcodes' with some success [1]. I would like to be
able to just insert new tapes and let bacula automatically label them using
the barcode read from the tape.
Is this
We have a tape library, 7 slots, 1 drive, barcode reader. All our tapes are
barcoded.
I've been using 'label barcodes' with some success [1].
This should work 100% of the time. It has for me for the 80 tapes I
have had it label. When I add new tapes, I wait 5 minutes for my 24
slot changer to
On 12 March 2010 12:44, John Drescher dresche...@gmail.com wrote:
We have a tape library, 7 slots, 1 drive, barcode reader. All our tapes
are
barcoded.
I've been using 'label barcodes' with some success [1].
This should work 100% of the time. It has for me for the 80 tapes I
have had
yeah, maybe it is a timing issue , (the changer isn't the newest) the msgs
didnt seem to be related to the job that was waiting, but i could be wrong.
The issue is that , say, slot 1 is labelled correctly, 2 and 3 not, 4
through 7 Ok. Sometimes it's one failed, sometimes 2, not the same all
On 12 March 2010 13:04, John Drescher dresche...@gmail.com wrote:
yeah, maybe it is a timing issue , (the changer isn't the newest) the
msgs
didnt seem to be related to the job that was waiting, but i could be
wrong.
The issue is that , say, slot 1 is labelled correctly, 2 and 3 not, 4