Re: [Bacula-users] Fwd: Baculum 11.0.2.1 Manage Autochanger.

2021-04-16 Thread Hector Barrera
Great. I removed the trailing \ (backslash) all good now. Have a great weekend! Hector Barrera. On Fri, Apr 16, 2021 at 12:12 PM Marcin Haba wrote: > Hello Hector, > > Great. Thanks for your positive feedback :-) > > For this additional " Changer Device = " string, it is a typo error in > bac

Re: [Bacula-users] Fwd: Baculum 11.0.2.1 Manage Autochanger.

2021-04-16 Thread Marcin Haba
Hello Hector, Great. Thanks for your positive feedback :-) For this additional " Changer Device = " string, it is a typo error in bacula-sd.conf. In my previous mail, when I sent the autochanger configuration, I didn't notice that there is a backslash quote character instead of quote character a

Re: [Bacula-users] Fwd: Baculum 11.0.2.1 Manage Autochanger.

2021-04-16 Thread Hector Barrera
That did it !!! Thank you so much Marcin for all your help with this. I'm now able to manage the autoloader magazines from within Baculum itself. I don't use the Quantum WEB GUI anymore for these tasks. I did discover a small bug in Baculum though, If you click on Storage -> Click on "Details" o

Re: [Bacula-users] Fwd: Baculum 11.0.2.1 Manage Autochanger.

2021-04-15 Thread Marcin Haba
Hello Hector, Many thanks for showing your Bacula configuration. Indeed, it explains why you experienced the problem with names in Baculum. I propose to use the following configuration below. I marked changed lines by "# Change X" marker bacula-dir.conf Storage { Name = "QUANTUM-LTO-changer1"

Re: [Bacula-users] Fwd: Baculum 11.0.2.1 Manage Autochanger.

2021-04-15 Thread Hector Barrera
OK. I believe the problem is how I got the bacula-dir.conf and bacula-sd.conf files configured. These are the pertinent parts: bacula-dir.conf Storage { Name = "File1" SdPort = 9103 Address = "bacula02.imn.ad" Password = "ZGZjNDMzZTg0OTR" Device = "FileChgr1" MediaType = "File1" Au

Re: [Bacula-users] Fwd: Baculum 11.0.2.1 Manage Autochanger.

2021-04-15 Thread Marcin Haba
Hello Hector, Thanks for more details. Your tape drive device is already named 'IBMLTO7' and it causes this collision. On screenshot, that you sent, I see another autochanger name "QUANTUM-LTO-Lib1" in storage daemon configuration. Does it mean that you have two autochangers: IBMLTO7 and QUANTUM-

Re: [Bacula-users] Fwd: Baculum 11.0.2.1 Manage Autochanger.

2021-04-15 Thread Marcin Haba
Hello Hector, Yes, everything looks correct on the screenshots. Thanks for them. In this case before looking in logs, I have a question about the autochanger name. When you run in bconsole the following command: show storage=IBMLTO7 could you tell me if in received output the 'DeviceName' value

Re: [Bacula-users] Fwd: Baculum 11.0.2.1 Manage Autochanger.

2021-04-14 Thread Marcin Haba
Hello Hector, At the beginning I would like to invite you to watch a video with the guide about configuring Autochanger in Baculum: https://www.youtube.com/watch?v=kPxpDTTD5Mk Baculum API needs to have access to the Autochanger. You can validate this access on the Baculum API side in add/edit au

[Bacula-users] Fwd: Baculum 11.0.2.1 Manage Autochanger.

2021-04-14 Thread Hector Barrera
Hello folks, I just upgraded to Bacula 11.0.1 and Baculum to ver. 11.0.2.1 Everything works, with the exception of being able to control our Quantum SuperLoader3 autochanger from within the Baculum interface. When I go to Storage, I don't see the Autochanger that I've configured via the Baculum