[Bacula-users] newb needs help configuring Dell PV-132T

2007-06-06 Thread Scott McDaniel
All, I am very green to bacula and am trying to configure a Dell PV-132T with a single LTO-3 drive attached to a Debian Etch server. My problem comes when running the btape fill test across multiple tapes. The first tape fills ok but I then get the following error when it needs to get the

Re: [Bacula-users] newb needs help configuring Dell PV-132T

2007-06-06 Thread Adam Cécile
Run update slots, then label barcodes Scott McDaniel a écrit : All, I am very green to bacula and am trying to configure a Dell PV-132T with a single LTO-3 drive attached to a Debian Etch server. My problem comes when running the btape fill test across multiple tapes. The first tape

Re: [Bacula-users] newb needs help configuring Dell PV-132T

2007-06-06 Thread Adam Cécile
Well... Let me explain you some stuff. PV132T has a barcodes reader, so the easier way to get bacula find its volumes into the library is to label tape with their barcodes. (I guess you have barcodes on your tape ???, check with mtx -f /dev/sgX status). Then start bacula director and run update