[casper] ROACH auto shuts off after 20 mins of running

2023-12-27 Thread Tommy Alford
Hello, we have a ROACH that we use as a correlator. It has been working great for the last 8 years or so but randomly while running the other day it shut itself off and now will not stay powered on for longer than around 20 minutes before auto shutting off again. The ROACH works completely norma

Re: [casper] ROACH auto shuts off after 20 mins of running

2023-12-27 Thread Aaron Parsons
Not an expert at this at all, but it could be that the ATX power supply has gone bad, or has had the connection to its sensor line (usually a bridge between pins 15 and 16) come loose . ATX has a sensor that will cause the power supply to go into standby, so you could check that connection, or try

[casper] FPGA boards - Donation.

2023-12-27 Thread Indrajit Barve
Dear CASPER team, Seasons greetings.. I am looking for CASPER FPGA board (ROACH 1 or 2)+ 2 Ch ADC. If anyone willing to donate it. Please let us know. Will write you more about the project in detail. Thanks and regards Indrajit -- You received this message because you are subscribed to the