There is an operating system bug in mac osx 10.5.x that may cause
this problem if you
are running the program with input redirection, but without output
redirection, i.e.,
cns < test.inp
and the input file contains one ore more blank lines.
try:
cns < test.inp > test.out
Axel Brunger
Hi,
Recently I've installed the CNS 1.2 on Mac Pro successfully. But when
I run cns_solve to do annealing refinement, the following error
information appear:
_
FFT3C: Using FFTPACK4.1
CNSsolve>{+ file: anneal.inp +}
CNSsolve>{+ d
Dear CCP4BBers
I have been a bit swamped by requests for the pdf of the Blake and
Phillips paper, so it can now be downloaded from:
http://www.biop.ox.ac.uk/www/garman/blake-and-phillips1962.pdf
Happy reading. It is an amazing piece of work since they didnt even know
the sequence of myoglobin
Dear all,
this is to remind you of the upcoming deadline for the
EMBO World Lecture Course on
RECENT DEVELOPMENTS IN MACROMOLECULAR CRYSTALLOGRAPHY
which I had announced earlier (see below).
Check out the web page http:/cwp.embo.org/wpc08-02/
or contact me for further informatio
Please see below for details or follow this link.
http://www.diamond.ac.uk/Jobs/CurrentVacancies/Scientific/DIA0408.htm
Job Reference & TitleDIA0408/SB - Life Sciences Co-ordinator
Type of post Scientific
Post details Permanent / full time
Division Science Divis
Andy
I guess it all depends on what temperature you mean by cryocooling. I
was not aware at the Low et. al. paper - interesting early work. Low
et. al. did not study reduction in radiation damage below -130C as they
noticed a large increase in mosaicity occurring so abandoned this
method. They did
Call for the Recruitment of a Researcher in the Area of Structural
Biology: Resolution of Three-dimensional Structures of Biological
Macromolecules by X-ray Crystallography
The Institute for Biocomputation and Physics of Complex Systems (BIFI),
University of Zaragoza,
(Spain), looks for a researc
Hi, All,
Thanks for all your replies. I checked the server as Pavel said, and
found that the 2.3A data has strong
anisotropy and other two has severe anisotropy. The recommend resolution
cutoff in the c axis is only
3.4A. I need to read more about the manual but I think this is the problem.
Ho