2014-10-30 Thread Derek Logan
Hi, I found that after upgrading to Yosemite and installing the latest version of X11 (2.7.7), X11 was now in /opt/X11R6 rather than /usr/X11R6. In my case ccp4i and coot both stopped working. I have no idea how the move happened, as no options were presented during installation of X11 to put i

Re: [ccp4bb] water at the same exactly position

2014-10-30 Thread luzuok
Dear Nat, But if there are other solvent molecules, such as Mg2+, SO4-,, in the same position. How can this problem be solved? Lu Zuokun -- 卢作焜 南开大学新生物站A202 在 2014-10-30 12:57:31,"Nat Echols" 写道: On Wed, Oct 29, 2014 at 8:53 PM, luzuok wrote: I think it is better for COOT t

Re: [ccp4bb] water at the same exactly position

2014-10-30 Thread Tim Gruene
-BEGIN PGP SIGNED MESSAGE- Hash: SHA1 Dear Lu Zuokun, it may appear tedious, but for a good quality model you should check every position and decide yourself what to place there. Automation will not replace your chemical understanding. Regards, Tim On 10/30/2014 10:56 AM, luzuok wrote:

Re: [ccp4bb] water at the same exactly position

2014-10-30 Thread Isaac Westwood
Dear Lu Zuokun, There are several methods you can use to locate these problem residues. Here are 3: a) manually step through your PDB file in coot (good practice anyway, this is fundamentally what we as crystallographers should be doing when we are model building) b) identify waters with close co

[ccp4bb] AW: [ccp4bb] water at the same exactly position

2014-10-30 Thread Herman . Schreuder
Dear Lu, I don’t see your problem. Why don’t you use the automatic water update option, present in most modern refinement programs, as Pavel suggested? This should take care of your problem. Of course, having premium, 1st class hand-picked waters is still the gold standard, but I don’t believe

Re: [ccp4bb] water at the same exactly position

2014-10-30 Thread Robbie Joosten
Hi Luzuok, Any validation program that detects clashes should hind these. Cheers, Robbie Sent from my Windows Phone Van: luzuok Verzonden: 30-10-2014 10:58 Aan: CCP4BB@JISCMAIL.AC.UK Onderwerp: Re: [ccp4bb] water at the same exactly position Dear Nat, But if t

[ccp4bb] 22nd West Coast Protein Crystallography Workshop

2014-10-30 Thread Nathan Henderson
Dear Colleagues, On behalf of the organizing committee, I call your attention to the upcoming 2015 West Coast Protein Crystallography Workshop (WCPCW), which is now open for registration. Below you will find information reposted from the WCPCW listserve. Nathan

[ccp4bb] Postdoc position for long-wavelength MX at Diamond Light Source

2014-10-30 Thread Armin Wagner
Postdoctoral Research Associate - Beamline I23 Beamline I23 at Diamond Light Source will be a unique facility for in-vacuum long-wavelength macromolecular crystallography (MX). After more than five years in design, construction and commissioning, we have recently collected first diffraction dat

Re: [ccp4bb] AW: [ccp4bb] water at the same exactly position

2014-10-30 Thread luzuok
Dear Herman, If there are duplicate atoms in my PDB, Phenix refine GUI will post error and crash (Sorry I haven't tried other refinement program). And there is no .geo output file if program crash. Phenix refine thought them as nonbonded atoms with distance equal to 0. Because the