CAT 3550 : IPX and AT support? [7:53642]

2002-09-19 Thread Diego Rissone
Does anybody know if the ios of the 3550's supports or will support ipx ? and at? thanks Diego Rissone CCIP,CCDP,CCNP,MSCE+I TECHINT GROUP -ARGENTINA Message Posted at: http://www.groupstudy.com/form/read.php?f=7&i=53642&t=53642 -

RE: Help, Switching Solution with 4006 [7:51799]

2002-08-21 Thread Diego Rissone
4232 L3 service blade functions only with the supii , no? regards - Diego CCIP, CCDP, CNNP Message Posted at: http://www.groupstudy.com/form/read.php?f=7&i=51855&t=51799 -- FAQ, list archives, and subscription info: http://www.groupstudy.com/lis

RE: 2505 - error erasing flash - write protected? [7:50013]

2002-07-30 Thread Diego Rissone
i run a similar problem a couple of months ago try this install the 8mb flash simm that have the ios image you want to boot in the first flash bank and put the second flash simm in the second bank. delete any file that resides in the second flash simm ( i can´t remember now if once must delet

RE: Metric in static routes? [7:50108]

2002-07-30 Thread Diego Rissone
really i need to have both routes for load balancing the problem is that only one link runs a routing proto and the other not i agree with you folks that the term metric of a static route is strange but i have no other term to describe the situation regards- Diego Message Posted at: http://www

Re: Metric in static routes? [7:50108]

2002-07-30 Thread Diego Rissone
yes chuck what you said is the only solution i implemented to this issue it´s tweaky but possible . one must take in account not only the feasible distance ( or metric ) of the distribution but also to set the administrative distance to be 90 for this specific operation so the router installs bo

RE: Metric in static routes? [7:50108]

2002-07-30 Thread Diego Rissone
Sanchez is right what you said but one thing is the administrative distance and the other is the metric . my concern is with the metric itself. as far as i know the metric can´t be modified for a static route regards - Diego Message Posted at: http://www.groupstudy.com/form/read.php?f=7&i=501

Metric in static routes? [7:50108]

2002-07-30 Thread Diego Rissone
Is there a way to configure a metric to a static route? One can configure the administrative distance. I have a situation where i want to have 2 routes in the routing table , one learned by eigrp and the other a static one the problem is even if i configure the ad of the static with 90 , only

Re: show process cpu and the interrupt value [7:49954]

2002-07-29 Thread Diego Rissone
The % of interrupt cpu is due to all interrupts being issued to the cpu . for the most part this value is due to an interrupt context switching method ( fast , optimun ,cef, netflow , etc) and also accounts for the usage of interrupts in the first part of a processs context switching method ( i.e

350-001: new or "old" contents [7:50071]

2002-07-29 Thread Diego Rissone
I have a doubt If i register for the 350-001 tomorrow and take it before aug 7 th, let's say the next friday, i will be tested on the old contents or the new ones ? thanks Diego ccip,ccdp,ccnp Techint Corp - Argentina Message Posted at: http://www.groupstudy.com/form/read.php?f=7&i=5007