Re: [load-threshold command]

2000-10-11 Thread fathar
Yes, The 2nd line will drop automatically dialer load-threshold Usage Guidelines This command applies to dialer rotary groups only. ""When the cumulative load of all UP links(a number n) exceeds the load threshold the dialer adds an extra link and when the cumulative load of all UP links m

Re: [redundancy]

2000-10-11 Thread fathar
Hi, You Can use "backup interface command" on primary interfacce so that when this goes down ,secondary will automatically kick up. The other command "Backup delay" will control the timing of link that how long it will take to get up or down. Interface Serial0 -- --- Backup inte

Re: [Dialer pool question!!]

2000-10-11 Thread fathar
Dear, Dialer interfaces are Logical, and not physical interfaces.. Thanks. Faisal. jeongwoo park <[EMAIL PROTECTED]> wrote: HI all. I have a conceptual question about dialer pool. As far as I know, a physical interface can belong to numerous dialer pools. Then here is a configuration. interfa

Re: [keepalive set in frame-relay circuit?]

2000-10-09 Thread fathar
Yeahh,, Thats 100 % Right Faisal. "Yee, Jason" <[EMAIL PROTECTED]> wrote: hi anyone knows why after having set my keepalive to be zero my frame-relay circuit straight away went up ie line protocol is up I believe there is no need to set keepalive as the LMI is taking care of it right? C