Hi all !
I am trying to connect win2000 station to cisco 2600 and to use callback. I
get connected, authenticated and
callback doesn`t happen. Station stays connected as if there was no callback
configured on the router. If I remove dialer callback-secure command from
dialer interface, call gets
OK, you've got a nice combination of ppp-callback, ms-callback, and
ISDN (CLI) callback all combined in that config.
You need to just have ms-callback so remove the "class test" stuff
from the dialer sting and also the "dialer caller 123 callback" line,
then change the "dialer remote-name" to
2 matches
Mail list logo